Your browser doesn't support javascript.
loading
Diagnosis of chronic B-cell lymphoproliferative disease in peripheral blood = how machine learning may help to the interpretation of flow cytometry data.
Gross, Zofia; Veyrat-Masson, Richard; Grange, Béatrice; Huet, Sarah; Verney, Aurélie; Traverse-Glehen, Alexandra; Ruminy, Philippe; Baseggio, Lucile.
Afiliação
  • Gross Z; Service clinique d'hématologie, Groupement Hospitalier Lyon-Sud/Hospices Civils de Lyon, Pierre-Bénite, France.
  • Veyrat-Masson R; Laboratoire d'hématologie, CHU ESTAING, Clermont Ferrand, France.
  • Grange B; Laboratoire d'hématologie spécialisée, Groupement Hospitalier Lyon-Sud/Hospices Civils de Lyon, Pierre-Bénite, France.
  • Huet S; Université Claude Bernard Lyon 1, Centre International de Recherche en Infectiologie (CIRI) INSERM U1111 - CNRS UMR5308, Lyon, France.
  • Verney A; Laboratoire d'hématologie spécialisée, Groupement Hospitalier Lyon-Sud/Hospices Civils de Lyon, Pierre-Bénite, France.
  • Traverse-Glehen A; Université Claude Bernard Lyon 1, Centre International de Recherche en Infectiologie (CIRI) INSERM U1111 - CNRS UMR5308, Lyon, France.
  • Ruminy P; Université Claude Bernard Lyon 1, Centre International de Recherche en Infectiologie (CIRI) INSERM U1111 - CNRS UMR5308, Lyon, France.
  • Baseggio L; Service d'anatomie-pathologique, Groupement Hospitalier Lyon-Sud/Hospices Civils de Lyon, Pierre-Bénite, France.
Hematol Oncol ; 42(1): e3245, 2024 Jan.
Article em En | MEDLINE | ID: mdl-38287532
ABSTRACT
Flow cytometry (FCM) has become a method of choice for immunologic characterization of chronic lymphoproliferative disease (CLPD). To reduce the potential subjectivities of FCM data interpretation, we developed a machine learning random forest algorithm (RF) allowing unsupervised analysis. This assay relies on 16 parameters obtained from our FCM screening panel, routinely used in the exploration of peripheral blood (PB) samples (mean fluorescence intensity values (MFI) of CD19, CD45, CD5, CD20, CD200, CD23, HLA-DR, CD10 in CD19-gated B cells, ratio of kappa/Lambda, and different ratios of MFI B-cells/T-cells [CD20, CD200, CD23]). The RF algorithm was trained and validated on a large cohort of more than 300 annotated different CLPD cases (chronic B-cell leukemia, mantle cell lymphoma, marginal zone lymphoma, follicular lymphoma, splenic red pulp lymphoma, hairy cell leukemia) and non-tumoral selected from PB samples. The RF algorithm was able to differentiate tumoral from non-tumoral B-cells in all cases and to propose a correct CLPD classification in more than 90% of cases. In conclusion the RF algorithm could be proposed as an interesting help to FCM data interpretation allowing a first B-cells CLPD diagnostic hypothesis and/or to guide the management of complementary analysis (additional immunologic markers and genetic).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Leucemia Linfocítica Crônica de Células B / Linfoma Folicular Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Revista: Hematol Oncol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Leucemia Linfocítica Crônica de Células B / Linfoma Folicular Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Revista: Hematol Oncol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: França