Your browser doesn't support javascript.
loading
Comparison of left atrial appendage measurements between conventional transesophageal echocardiography and "Virtual TEE" reconstructed from computed tomography for pre-procedural planning of device closure.
Cho, Natsuki; Nakajima, Yoshifumi; Kubo, Shunsuke; Hara, Hidehiko; Nanasato, Mamoru; Hozawa, Maiko; Doi, Akio; Morino, Yoshihiro.
Afiliação
  • Cho N; Division of Cardiology, Department of Internal Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate, 028-3695, Japan.
  • Nakajima Y; Division of Cardiology, Department of Internal Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate, 028-3695, Japan. ynaka@iwate-med.ac.jp.
  • Kubo S; Department of Cardiovascular Medicine, Kurashiki Central Hospital, Okayama, Japan.
  • Hara H; Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, Tokyo, Japan.
  • Nanasato M; Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
  • Hozawa M; Division of Cardiology, Department of Internal Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate, 028-3695, Japan.
  • Doi A; Faculty of Software and Information Science, Iwate Prefectural University, Iwate, Japan.
  • Morino Y; Division of Cardiology, Department of Internal Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate, 028-3695, Japan.
Heart Vessels ; 39(6): 539-548, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38329512
ABSTRACT
For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ecocardiografia Transesofagiana / Apêndice Atrial Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ecocardiografia Transesofagiana / Apêndice Atrial Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão