Your browser doesn't support javascript.
loading
Mobility Selective Ion Soft-Landing and Characterization Enabled Using Structures for Lossless Ion Manipulation.
Lee, Jung Y; Li, Ailin; Prabhakaran, Venkateshkumar; Zhang, Xin; Harrilal, Christopher P P; Kovarik, Libor; Ibrahim, Yehia M; Smith, Richard D; Garimella, Sandilya V B.
Afiliação
  • Lee JY; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Li A; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Prabhakaran V; Physical Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Zhang X; Physical Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Harrilal CPP; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Kovarik L; Physical Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Ibrahim YM; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Smith RD; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Garimella SVB; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
Anal Chem ; 96(8): 3373-3381, 2024 Feb 27.
Article em En | MEDLINE | ID: mdl-38345945
ABSTRACT
While conventional ion-soft landing uses the mass-to-charge (m/z) ratio to achieve molecular selection for deposition, here we demonstrate the use of Structures for Lossless Ion Manipulation (SLIM) for mobility-based ion selection and deposition. The dynamic rerouting capabilities of SLIM were leveraged to enable the rerouting of a selected range of mobilities to a different SLIM path (rather than MS) that terminated at a deposition surface. A selected mobility range from a phosphazene ion mixture was rerouted and deposited with a current pulse (∼150 pA) resembling its mobility peak. In addition, from a mixture of tetra-alkyl ammonium (TAA) ions containing chain lengths of C5-C8, selected chains (C6, C7) were collected on a surface, reconstituted into solution-phase, and subsequently analyzed with a SLIM-qToF to obtain an IMS/MS spectrum, confirming the identity of the selected species. Further, this method was used to characterize triply charged tungsten-polyoxometalate anions, PW12O403- (WPOM). The arrival time distribution of the IMS/MS showed multiple peaks associated with the triply charged anion (PW12O403-), of which a selected ATD was deposited and imaged using TEM. Additionally, the identity of the deposited WPOM was ascertained using energy-dispersive (EDS) spectroscopy. Further, we present theory and computations that reveal ion landing energies, the ability to modulate the energies, and deposition spot sizes.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos