Your browser doesn't support javascript.
loading
Hyperventilation testing in the diagnosis of vasospastic angina: A clinical review and meta-analysis.
Boivin-Proulx, Laurie-Anne; Marquis-Gravel, Guillaume; Rousseau-Saine, Nicolas; Harel, François; Jolicoeur, E Marc; Pelletier-Galarneau, Matthieu.
Afiliação
  • Boivin-Proulx LA; Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, Canada.
  • Marquis-Gravel G; Montreal Heart Institute, University of Montreal, Montreal, Quebec, Canada.
  • Rousseau-Saine N; Montreal Heart Institute, University of Montreal, Montreal, Quebec, Canada.
  • Harel F; Montreal Heart Institute, University of Montreal, Montreal, Quebec, Canada.
  • Jolicoeur EM; CHUM Research Center and Cardiovascular Center, Montreal, Quebec, Canada.
  • Pelletier-Galarneau M; Montreal Heart Institute, University of Montreal, Montreal, Quebec, Canada.
Eur J Clin Invest ; 54(6): e14178, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38348627
ABSTRACT

BACKGROUND:

Given the limited access to invasive vasospastic reactivity testing in Western Countries, there is a need to further develop alternative non-invasive diagnostic methods for vasospastic angina (VSA). Hyperventilation testing (HVT) is defined as a class IIa recommendation to diagnose VSA by the Japanese Society of Cardiology.

METHODS:

In this systematic review and meta-analysis reported according to the PRISMA statement, we review the mechanisms, methods, modalities and diagnostic accuracy of non-invasive HVT for the diagnostic of VSA.

RESULTS:

A total of 106 articles published between 1980 and 2022 about VSA and HVT were included in the systematic review, among which 16 were included in the meta-analysis for diagnostic accuracy. Twelve electrocardiogram-HVT studies including 804 patients showed a pooled sensitivity of 54% (95% confidence intervals [CI]; 30%-76%) and a pooled specificity of 99% (95% CI; 88%-100%). Four transthoracic echocardiography-HVT studies including 197 patients revealed a pooled sensitivity of 90% (95% CI; 82%-94%) and a pooled specificity of 98% (95% CI; 86%-100%). Six myocardial perfusion imaging-HVT studies including 112 patients yielded a pooled sensitivity of 95% (95% CI; 63%-100%) and a pooled specificity of 78% (95% CI; 19%-98%). Non-invasive HVT resulted in a low rate of adverse events, ventricular arrhythmias being the most frequently reported, and were resolved with the administration of nitroglycerin.

CONCLUSIONS:

Non-invasive HVT offers a safe alternative with high diagnostic accuracy to diagnose VSA in patients with otherwise undiagnosed causes of chest pain.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Vasoespasmo Coronário / Eletrocardiografia / Hiperventilação Tipo de estudo: Diagnostic_studies / Guideline / Systematic_reviews Limite: Humans Idioma: En Revista: Eur J Clin Invest Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Vasoespasmo Coronário / Eletrocardiografia / Hiperventilação Tipo de estudo: Diagnostic_studies / Guideline / Systematic_reviews Limite: Humans Idioma: En Revista: Eur J Clin Invest Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Canadá