Your browser doesn't support javascript.
loading
Enantiomeric analysis of chiral phenyl aromatic compounds by coated capillary electrochromatography based on a MOF-on-MOF stationary phase.
Miao, Pandeng; Chen, Jiaquan; Xu, Guangfu; Yu, Tao; Du, Yingxiang.
Afiliação
  • Miao P; Key Laboratory of Drug Quality Control and Pharmacovigilance (Ministry of Education), China Pharmaceutical University, Nanjing, 210009, People's Republic of China.
  • Chen J; State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing, 210009, People's Republic of China.
  • Xu G; Key Laboratory of Drug Quality Control and Pharmacovigilance (Ministry of Education), China Pharmaceutical University, Nanjing, 210009, People's Republic of China.
  • Yu T; State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing, 210009, People's Republic of China.
  • Du Y; Key Laboratory of Drug Quality Control and Pharmacovigilance (Ministry of Education), China Pharmaceutical University, Nanjing, 210009, People's Republic of China.
Mikrochim Acta ; 191(3): 160, 2024 Feb 27.
Article em En | MEDLINE | ID: mdl-38411791
ABSTRACT
Chiral phenyl aromatic compounds (CPACs) are widely used in drug development, food/cosmetic production, and other organic synthesis processes, and their different enantiomers have distinct physiological activities and application differences. A double-layer metal-organic framework composite (MOF-on-MOF) was obtained by in situ synthesis of chiral metal-organic framework (CMOM-3S) on the surface of an iron-based metal-organic framework (NH2-MIL-101(Fe)). According to our investigation, MOF-on-MOF composite was for the first time applied to the stationary phase of capillary electrochromatography (CEC), and enantioseparations of eight CPACs were accomplished. Compared with single CMOM-3S, the enantioseparation performance of the coated capillary columns based on NH2-MIL-101(Fe)@CMOM-3S was improved by 34.07 ~ 720.0%. The R-/S-mandelic acid in actual sample (apricot leaves) was detected by the newly CEC system to be 0.0118 mg mL-1 and 0.0523 mg mL-1, respectively. The spike recoveries were 96.60 ~ 104.7%, indicating its good stability and accuracy. In addition, the selective adsorption capacity of MOF-on-MOF composites was verified by adsorption experiments.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article