Your browser doesn't support javascript.
loading
How to overcome the difficulty in assaying Ni in biodiesel samples? Extraction induced by microemulsion breaking and square wave adsorptive stripping voltammetry could be the answer.
Krause, Cristian H; Schneider, Alexandre B; Kolling, Leandro; de Morais, Pedro H S R; da Silva, Marcia M.
Afiliação
  • Krause CH; Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, C.P. 15003, 91501-970, Porto Alegre, RS, Brazil.
  • Schneider AB; Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, C.P. 15003, 91501-970, Porto Alegre, RS, Brazil. Electronic address: schneider.alexandre@ufrgs.br.
  • Kolling L; Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, C.P. 15003, 91501-970, Porto Alegre, RS, Brazil.
  • de Morais PHSR; Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, C.P. 15003, 91501-970, Porto Alegre, RS, Brazil.
  • da Silva MM; Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, C.P. 15003, 91501-970, Porto Alegre, RS, Brazil.
Talanta ; 272: 125776, 2024 May 15.
Article em En | MEDLINE | ID: mdl-38428129
ABSTRACT
Herein, a simple, green, and relatively inexpensive approach to determine nickel (Ni) in biodiesel samples by square wave adsorptive cathodic stripping voltammetry (SWAdCSV) is presented. A method based on the accumulation of Ni as Ni(II)-dimethylglyoxime (Ni(II)(HDMG)2) on the glassy carbon electrode was carried out in a solution containing the aqueous phase extract (APhEx) obtained from an extraction induced by microemulsion breaking (EIMB), which was achieved by adding a few microliters of ultrapure water to a microemulsion composed of biodiesel, n-propanol and a diluted HNO3 solution. The LOD and LOQ were 0.2 µg L-1 and 0.8 µg L-1, respectively, and the accuracy was evaluated by recovery assays of spiked samples and by analyzing a standard reference material. Results obtained from a comparative method (HR-CS GF AAS) were also used for this evaluation. The method was applied to biodiesel samples produced from different feedstocks. To the best of the authors knowledge, it is the first time that 1) Ni in biodiesel is determined by a voltammetric method; 2) EIMB is applied to extract Ni from this matrix and 3) this type of sample preparation method is used with adsorptive stripping voltammetry.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil