Rapid Screening of 34 Emerging Contaminants in Surface Water by UHPLC-Q-TOF-MS.
Lü, Chen-Shan; Cao, Yi-Xuan; Mu, Xiao-Xi; Cui, Hai-Yan; Wang, Tao; Wei, Zhi-Wen; Yun, Ke-Ming; Hu, Meng.
Afiliação
  • Lü CS; School of Forensic Medicine, Shanxi Medical University, Jinzhong 030600, Shanxi Province, China.
  • Cao YX; Shanxi Key Laboratory of Forensic Medicine, Jinzhong 030600, Shanxi Province, China.
  • Mu XX; Key Laboratory of Forensic Toxicology of Ministry of Public Security, Jinzhong 030600, Shanxi Province, China.
  • Cui HY; School of Forensic Medicine, Shanxi Medical University, Jinzhong 030600, Shanxi Province, China.
  • Wang T; Shanxi Key Laboratory of Forensic Medicine, Jinzhong 030600, Shanxi Province, China.
  • Wei ZW; Key Laboratory of Forensic Toxicology of Ministry of Public Security, Jinzhong 030600, Shanxi Province, China.
  • Yun KM; School of Forensic Medicine, Shanxi Medical University, Jinzhong 030600, Shanxi Province, China.
  • Hu M; Shanxi Key Laboratory of Forensic Medicine, Jinzhong 030600, Shanxi Province, China.
Fa Yi Xue Za Zhi ; 40(1): 30-36, 2024 Feb 25.
Article em En, Zh | MEDLINE | ID: mdl-38500458
ABSTRACT

OBJECTIVES:

To establish a rapid screening method for 34 emerging contaminants in surface water by ultra-high performance liquid chromatography-quadrupole-time of flight mass spectrometry (UHPLC-Q-TOF-MS).

METHODS:

The pretreatment conditions of solid phase extraction (SPE) were optimized by orthogonal experimental design and the surface water samples were concentrated and extracted by Oasis® HLB and Oasis® MCX SPE columns in series. The extracts were separated by Kinetex® EVO C18 column, with gradient elution of 0.1% formic acid aqueous solution and 0.1% formic acid methanol solution. Q-TOF-MS 'fullscan' and 'targeted MS/MS' modes were used to detect 34 emerging contaminants and to establish a database with 34 emerging contaminants precursor ion, product ion and retention times.

RESULTS:

The 34 emerging contaminants exhibited good linearity in the concentration range respectively and the correlation coefficients (r) were higher than 0.97. The limit of detection was 0.2-10 ng/L and the recoveries were 81.2%-119.2%. The intra-day precision was 0.78%-18.70%. The method was applied to analyze multiple surface water samples and 6 emerging contaminants were detected, with a concentration range of 1.93-157.71 ng/L.

CONCLUSIONS:

The method is simple and rapid for screening various emerging contaminants at the trace level in surface water.