Your browser doesn't support javascript.
loading
A calibration-free c-VEP based BCI employing narrow-band random sequences.
Zheng, Li; Dong, Yida; Tian, Sen; Pei, Weihua; Gao, Xiaorong; Wang, Yijun.
Afiliação
  • Zheng L; Laboratory of Solid State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, People's Republic of China.
  • Dong Y; Laboratory of Solid State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, People's Republic of China.
  • Tian S; School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China.
  • Pei W; Brain Machine Fusion Intelligence Institute, Suzhou 215133, People's Republic of China.
  • Gao X; Laboratory of Solid State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, People's Republic of China.
  • Wang Y; School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China.
J Neural Eng ; 21(2)2024 04 02.
Article em En | MEDLINE | ID: mdl-38513290
ABSTRACT
Objective.Code-modulated visual evoked potential (c-VEP) based brain-computer interfaces (BCIs) exhibit high encoding efficiency. Nevertheless, the majority of c-VEP based BCIs necessitate an initial training or calibration session, particularly when the number of targets expands, which impedes the practicality. To address this predicament, this study introduces a calibration-free c-VEP based BCI employing narrow-band random sequences.Approach.For the encoding method, a series of random sequences were generated within a specific frequency band. The c-VEP signals were subsequently elicited through the application of on-type grid flashes that were modulated by these sequences. For the calibration-free decoding algorithm, filter-bank canonical correlation analysis (FBCCA) was utilized with the reference templates generated from the original sequences. Thirty-five subjects participated into an online BCI experiment. The performances of c-VEP based BCIs utilizing narrow-band random sequences with frequency bands of 15-25 Hz (NBRS-15) and 8-16 Hz (NBRS-8) were compared with that of a steady-state visual evoked potential (SSVEP) based BCI within a frequency range of 8-15.8 Hz.Main results.The offline analysis results demonstrated a substantial correlation between the c-VEPs and the original narrow-band random sequences. After parameter optimization, the calibration-free system employing the NBRS-15 frequency band achieved an average information transfer rate (ITR) of 78.56 ± 37.03 bits/min, which exhibited no significant difference compared to the performance of the SSVEP based system when utilizing FBCCA. The proposed system achieved an average ITR of 102.1 ± 57.59 bits/min in a simulation of a 1000-target BCI system.Significance.This study introduces a novel calibration-free c-VEP based BCI system employing narrow-band random sequences and shows great potential of the proposed system in achieving a large number of targets and high ITR.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Potenciais Evocados Visuais / Interfaces Cérebro-Computador Limite: Humans Idioma: En Revista: J Neural Eng Assunto da revista: NEUROLOGIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Potenciais Evocados Visuais / Interfaces Cérebro-Computador Limite: Humans Idioma: En Revista: J Neural Eng Assunto da revista: NEUROLOGIA Ano de publicação: 2024 Tipo de documento: Article