Your browser doesn't support javascript.
loading
Laboratory and field evaluation of a low-cost optical particle sizer.
Tang, Mingzhen; Shen, Yicheng; Ge, Yanzhen; Gao, Jian; Wang, Chong; Wu, Liqing; Si, Shuchun.
Afiliação
  • Tang M; State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China.
  • Shen Y; State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China.
  • Ge Y; Tai'an Ecological Environment Protection Control Center, Tai'an 271000, China.
  • Gao J; State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China. Electronic address: gaojian@craes.org.cn.
  • Wang C; Jinan Grid-Based Supervision Center of Ecological and Environmental Protection, Jinan 250100, China. Electronic address: jnhbjwangchong@jn.shandong.cn.
  • Wu L; State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China.
  • Si S; School of Physics, Shandong University, Jinan 250013, China.
J Environ Sci (China) ; 142: 215-225, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38527887
ABSTRACT
Low-cost sensors are widely used to collect high-spatial-resolution particulate matter data that traditional reference monitoring devices cannot. In addition to the mass concentration, the number concentration and size distribution are also fundamental in determining the origin and hazard level of particulate pollution. Therefore, low-cost optical sensors have been improved to establish optical particle sizers (OPSs). In this study, a low-cost OPS, the Nova SDS029, is introduced, and it is evaluated in comparison to two reference instruments-the GRIMM 11-D and the TSI 3330. We first tested the sizing accuracy using polystyrene latex spheres. Then, we assessed the mass and number size distribution accuracy in three application scenarios indoor smoking, ambient air quality, and mobile monitoring. The evaluations suggest that the low-cost SDS029 rivals research-grade optical sizers in many aspects. For example, (1) the particle diameters obtained with the SDS029 are close to the reference instruments (usually < 10%) in the 0.3-5 µm range; (2) the number of particles and mass concentration are highly correlated (r ≥ 0.99) with the values obtained with the reference instruments; and (3) the SDS029 slightly underestimates the number concentration, but the derived PM2.5 values are closer to monitoring station than the reference instruments. The successful application of the SDS029 in multiple scenarios suggests that a plausible particle size distribution can be obtained in an easy and cost-efficient way. We believe that low-cost OPSs will increasingly be used to map the sources and risk levels of particles at the city scale.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Atmosféricos / Poluição do Ar Idioma: En Revista: J Environ Sci (China) Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Atmosféricos / Poluição do Ar Idioma: En Revista: J Environ Sci (China) Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China