Your browser doesn't support javascript.
loading
Long-terms outcomes of radial head arthroplasty using a bipolar prosthesis.
Celli, Andrea; Paroni, Chiara; Bonucci, Pierluigi; Celli, Luigi.
Afiliação
  • Celli A; Shoulder and Elbow Unit, Department of Orthopaedic Surgery, Hesperia Hospital, Modena, Italy. celli.andrea.md@gmail.com.
  • Paroni C; , Via Emilia Est 380\1, Modena, 41124, Italy. celli.andrea.md@gmail.com.
  • Bonucci P; Shoulder and Elbow Unit, Department of Orthopaedic Surgery, Hesperia Hospital, Modena, Italy.
  • Celli L; Shoulder and Elbow Unit, Department of Orthopaedic Surgery, Hesperia Hospital, Modena, Italy.
Arch Orthop Trauma Surg ; 144(5): 2007-2017, 2024 May.
Article em En | MEDLINE | ID: mdl-38568386
ABSTRACT

BACKGROUND:

In acute treatment of radial head fractures, a radial head prosthesis can be considered if open reduction and internal fixation are not technically feasible.

METHODS:

We reviewed the data of 27 consecutive bipolar Judet radial head prostheses implanted in patients with unreconstructable radial head fractures and no other concomitant fractures (coronoid or olecranon factures). The lesions of the lateral collateral ligament were rated according to the McKee classification. Twenty-three patients with more than ten-year follow-up participated in this retrospective study All patients underwent assessments for pain, range of motion and stability using the Mayo Elbow Performance Score, the QuickDash questionnaire and a Visual Analogue Scale for pain. Radiography assessment was performed to determine the correct setting of the implant, presence of periprosthetic loosening, prosthetic disassembly, heterotopic ossification, capitellum and ulnohumeral degenerative changes.

RESULTS:

Mean follow-up was 149 months (± 12.2). Mean range of motion in flexion-extension was 111° (± 10.55), mean extension was 18° (± 14.32) and mean flexion was 130° (± 11.4). Mean arc of motion in supination-pronation was 150° (± 12.26). The mean Mayo Elbow Performance Score was 88, the mean QuickDash score was 7.3; 86% of the patients were satisfied. Seven patients (26%) required secondary surgery. The most frequent complication was heterotopic ossification, which had negative consequences on the functional result.

CONCLUSIONS:

Bipolar radial head prostheses are an option for acute treatment of isolated unreconstructable radial head fractures. During follow-up, three patients required implant revision and removal; the capitellum surface presented severe degenerative changes and the prosthesis was not replaced. Another complication was the risk of implant dislocation, in relation to implant design, incorrect positioning of the radial head stem or else to inadequate reconstruction of the lateral collateral ligament. Further work is needed to establish the long-term follow-up results of Judet implants in complex elbow fractures.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Rádio / Articulação do Cotovelo Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Rádio / Articulação do Cotovelo Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália