Production of [211At]NaAt solution under GMP compliance for investigator-initiated clinical trial.
Naka, Sadahiro; Ooe, Kazuhiro; Shirakami, Yoshifumi; Kurimoto, Kenta; Sakai, Toshihiro; Takahashi, Kazuhiro; Toyoshima, Atsushi; Wang, Yang; Haba, Hiromitsu; Kato, Hiroki; Tomiyama, Noriyuki; Watabe, Tadashi.
Afiliação
  • Naka S; Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Ooe K; Department of Pharmacy, Osaka University Hospital, 2-15 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Shirakami Y; Institute for Radiation Sciences, Osaka University, 2-4 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Kurimoto K; Institute for Radiation Sciences, Osaka University, 2-4 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Sakai T; Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Takahashi K; Department of Pharmacy, Osaka University Hospital, 2-15 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Toyoshima A; Hanwa Intelligent Medical Center, Hanwa Daini Senboku Hospital, 3176 Fukaikitamachi, Naka- ku, Sakai, Osaka, 599-8271, Japan.
  • Wang Y; Advanced Clinical Research Center, Fukushima Global Medical Science Center, Fukushima Medical University, 1 Hikarigaoka, Fukushima, Fukushima, 960-1295, Japan.
  • Haba H; Institute for Radiation Sciences, Osaka University, 2-4 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Kato H; Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako, Saitama, 351-0198, Japan.
  • Tomiyama N; Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako, Saitama, 351-0198, Japan.
  • Watabe T; Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
EJNMMI Radiopharm Chem ; 9(1): 29, 2024 Apr 15.
Article em En | MEDLINE | ID: mdl-38619655
ABSTRACT

BACKGROUND:

The alpha emitter astatine-211 (211At) is garnering attention as a novel targeted alpha therapy for patients with refractory thyroid cancer resistant to conventional therapy using beta emitter radioiodine (131I). Herein, we aimed to establish a robust method for the manufacturing and quality control of [211At]NaAt solution for intravenous administration under the good manufacturing practice guidelines for investigational products to conduct an investigator-initiated clinical trial.

RESULTS:

211At was separated and purified via dry distillation using irradiated Bi plates containing 211At obtained by the nuclear reaction of 209Bi(4He, 2n)211At. After purification, the 211At trapped in the cold trap was collected in a reaction vessel using 15 mL recovery solution (1% ascorbic acid and 2.3% sodium hydrogen carbonate). After stirring the 211At solution for 1 h inside a closed system, the reaction solution was passed through a sterile 0.22 µm filter placed in a Grade A controlled area and collected in a product vial to prepare the [211At]NaAt solution. According to the 3-lot tests, decay collected radioactivity and radiochemical yield of [211At]NaAt were 78.8 ± 6.0 MBq and 40 ± 3%, respectively. The radiochemical purity of [211At]At- obtained via ion-pair chromatography at the end of synthesis (EOS) was 97 ± 1%, and remained > 96% 6 h after EOS; it was detected at a retention time (RT) 3.2-3.3 min + RT of I-. LC-MS analysis indicated that this principal peak corresponded with an astatide ion (m/z = 210.988046). In gamma-ray spectrometry, the 211At-related peaks were identified (X-ray 76.9, 79.3, 89.3, 89.8, and 92.3 keV; γ-ray 569.7 and 687.0 keV), whereas the peak at 245.31 keV derived from 210At was not detected during the 22 h continuous measurement. The target material, Bi, was below the 9 ng/mL detection limit in all lots of the finished product. The pH of the [211At]NaAt solution was 7.9-8.6; the concentration of ascorbic acid was 9-10 mg/mL. Other quality control tests, including endotoxin and sterility tests, confirmed that the [211At]NaAt solution met all quality standards.

CONCLUSIONS:

We successfully established a stable method of [211At]NaAt solution that can be administered to humans intravenously as an investigational product.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: EJNMMI Radiopharm Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: EJNMMI Radiopharm Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão