Your browser doesn't support javascript.
loading
Diffusion tensor imaging combined with the dual-echo steady-state (DESS) protocol for the evaluation of the median nerve in the carpal tunnel: A preliminary study.
Maki, Yoshinori; Takayama, Motohiro; Okawa, Tsuyoshi; Goda, Akio; Miyakoshi, Akinori.
Afiliação
  • Maki Y; Department of Neurosurgery, Hikone Chuo Hospital, Hikone, Japan.
  • Takayama M; Department of Neurosurgery, Hikone Chuo Hospital, Hikone, Japan.
  • Okawa T; Department of Radiology, Fujieda Municipal General Hospital, Fujieda, Japan.
  • Goda A; Department of Physical Therapy, Faculty of Health and Medical Sciences, Hokuriku University, Kanazawa, Japan.
  • Miyakoshi A; Department of Neurosurgery, Shizuoka General Hospital, Shizuoka, Japan.
Surg Neurol Int ; 15: 110, 2024.
Article em En | MEDLINE | ID: mdl-38628509
ABSTRACT

Background:

Carpal tunnel syndrome (CTS) is diagnosed based on neurological, electrophysiology, and radiological findings. Due to the technical development of magnetic resonance imaging (MRI), the median nerve is evaluated with several MRI protocols. However, diffusion tensor imaging (DTI) combined with a dual-echo steady-state (DESS) protocol is not frequently used to evaluate the median nerve of CTS. This study aimed to evaluate the median nerve in the carpal tunnel using DTI combined with a DESS protocol.

Methods:

Five healthy volunteers and seven patients with CTS were enrolled. The patients underwent MRI for CTS pre- and post-operatively. The median nerve was evaluated using a 3-T MRI scanner. The parameters of the DESS protocol were as follows Repetition time (TR)/echo time (TE) = 10.83/3.32 ms, slice thickness = 0.45 mm, field of view (FoV) = 350 × 253 × 350 mm, and 3D voxel size = 0.5 × 0.5 ×0.4 mm. The parameters of the DTI sequence were as follows TR/TE = 4000/86 ms, slice thickness = 3 mm, FoV = 160 × 993 × 90 mm, 3D voxel size = 1.2 × 1.2 ×3.0 mm, and b value = 0.1000 s/mm2. The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of the median nerve were statistically analyzed. Statistical significance was set at P< 0.05.

Results:

The FA value of healthy volunteers was 0.576 ± 0.058, while those of the patients were 0.357 ± 0.094 and 0.395 ± 0.062 pre-and post-operatively, respectively. Statistically significant differences were identified between the FA values of healthy volunteers and pre-operative/post-operative patients. The ADC values of healthy volunteers and pre-operative patients were 0.931 ± 0.096 and 1.26 ± 0.282 (10-3 mm2/s), respectively (P< 0.05).

Conclusion:

This MRI protocol may be useful for evaluating the median nerve in the carpal tunnel.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Surg Neurol Int Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Surg Neurol Int Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão