Your browser doesn't support javascript.
loading
Intra- and Inter-Rater Reliability of Processing Ultrasound Tissue Characterization Scans in Midportion Achilles Tendinopathy.
Paantjens, Marc Adriaan; Helmhout, Pieter Herman; Gerardus Backx, Franciscus Jacobus; Willibrord Martens, Meindert Thomas Annechien; van Dongen, Joeri Paulus Adrianus; Petrus Bakker, Eric Wilhelmus.
Afiliação
  • Paantjens MA; Sports Medicine Centre, Training Medicine and Training Physiology, Royal Netherlands Army, Utrecht, Netherlands.
  • Helmhout PH; Department of Rehabilitation, Physical Therapy Science and Sports, University Medical Center Utrecht, Utrecht, Netherlands.
  • Gerardus Backx FJ; Centre of Excellence, Training Medicine and Training Physiology, Royal Netherlands Army, Utrecht, Netherlands.
  • Willibrord Martens MTA; Department of Rehabilitation, Physical Therapy Science and Sports, University Medical Center Utrecht, Utrecht, Netherlands.
  • van Dongen JPA; Fontys University of Applied Science, Eindhoven, Netherlands.
  • Petrus Bakker EW; National Institute of Musculoskeletal Ultrasound, Vianen, Netherlands.
Transl Sports Med ; 2022: 9348298, 2022.
Article em En | MEDLINE | ID: mdl-38655162
ABSTRACT

Purpose:

Ultrasound tissue characterization (UTC) is used to visualize and quantify the Achilles tendon structure. We investigated the intra-rater and inter-rater reliability of UTC for quantifying the midportion tendon structure and the area of maximum degeneration (AoMD) in military personnel with midportion Achilles tendinopathy.

Method:

UTC scans of 50 patients (16-60 years) were processed twice by rater 1 and once by rater 2. First, the midportion tendon structure was quantified and subsequently the AoMD. The intraclass correlation coefficient (ICC) was calculated for echo-types I, II, III, IV, aligned fibrillar structure (echo-types I + II), and disorganized tendon structure (echo-types III + IV).

Results:

For midportion tendon structure, all ICC values were excellent for intra-rater reliability (range 0.97 to 0.99) and inter-rater reliability (range 0.98 to 0.99). Regarding the AoMD, intra-rater reliability showed excellent ICC values for all echo-types (range 0.94 to 0.98) except for echo-type II (0.85). Inter-rater reliability showed excellent ICC values for all echo-types (range 0.92 to 0.98).

Conclusion:

Processing of UTC scans is highly reliable in quantifying the midportion Achilles tendon structure and the AoMD.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Transl Sports Med Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Transl Sports Med Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda