Your browser doesn't support javascript.
loading
Label- and Reagent-Free Optical Sensor for Absorption-Based Detection of Urea Concentration in Water Solutions.
Anelli, Carlo; Pellicorio, Vanessa; Bello, Valentina; Merlo, Sabina.
Afiliação
  • Anelli C; Department of Electrical, Computer and Biomedical Engineering, University of Pavia, Via Ferrata 5, 27100 Pavia, Italy.
  • Pellicorio V; Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100 Pavia, Italy.
  • Bello V; Department of Electrical, Computer and Biomedical Engineering, University of Pavia, Via Ferrata 5, 27100 Pavia, Italy.
  • Merlo S; Department of Electrical, Computer and Biomedical Engineering, University of Pavia, Via Ferrata 5, 27100 Pavia, Italy.
Sensors (Basel) ; 24(9)2024 Apr 26.
Article em En | MEDLINE | ID: mdl-38732860
ABSTRACT
Contactless and label-free detection of urea content in aqueous solutions is of great interest in chemical, biomedical, industrial, and automotive applications. In this work, we demonstrate a compact and low-cost instrumental configuration for label-free, reagent-free, and contactless detection of urea dissolved in water, which exploits the absorption properties of urea in the near-infrared wavelength region. The intensity of the radiation transmitted through the fluid under test, contained in a rectangle hollow glass tubing with an optical pathlength of 1 mm, is detected in two spectral bands. Two low-cost, low-power LEDs with emission spectra centered at λ = 1450 nm and λ = 2350 nm are used as readout sources. The photodetector is positioned on the other side of the tubing, in front of the LEDs. The detection performances of a photodiode and of a thermal optical power detector have been compared, exploiting different approaches for LED driving current modulation and photodetected signal processing. The implemented detection system has been tested on urea-water solutions with urea concentrations from 0 up to 525 mg/mL as well as on two samples of commercial diesel exhaust fluid ("AdBlue™"). Considering the transmitted intensity in presence of the urea-water solution, at λ = 1450 nm and λ = 2350 nm, normalized to the transmitted intensity in presence of water, we demonstrate that their ratio is linearly related to urea concentration on a wide range and with good sensitivity.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália