Evaluation of the Truncated Cone-Rhomboid Pyramid Formula for Simplified Right Ventricular Quantification: A Cardiac Magnetic Resonance Study.
Kirschfink, Annemarie; Frick, Michael; Al Ateah, Ghazi; Kneizeh, Kinan; Alnaimi, Anas; Dettori, Rosalia; Schuett, Katharina; Marx, Nikolaus; Altiok, Ertunc.
Afiliação
  • Kirschfink A; Department of Cardiology, Angiology and Intensive Care, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
  • Frick M; Department of Cardiology, Angiology and Intensive Care, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
  • Al Ateah G; Department of Cardiology, Nephrology and Internal Intensive Care Medicine, Rhein-Maas Klinikum, Mauerfeldchen 25, 52146 Wuerselen, Germany.
  • Kneizeh K; Department of Cardiology, Angiology and Intensive Care, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
  • Alnaimi A; Department of Cardiology, Angiology and Intensive Care, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
  • Dettori R; Department of Cardiology, Angiology and Intensive Care, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
  • Schuett K; Department of Cardiology, Angiology and Intensive Care, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
  • Marx N; Department of Cardiology, Angiology and Intensive Care, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
  • Altiok E; Department of Cardiology, Angiology and Intensive Care, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
J Clin Med ; 13(10)2024 May 12.
Article em En | MEDLINE | ID: mdl-38792392
ABSTRACT
Background/

Objective:

Cardiac magnetic resonance (CMR) is the reference method for right ventricular (RV) volume and function analysis, but time-consuming manual segmentation and corrections of imperfect automatic segmentations are needed. This study sought to evaluate the applicability of an echocardiographically established truncated cone-rhomboid pyramid formula (CPF) for simplified RV quantification using CMR.

Methods:

A total of 70 consecutive patients assigned to RV analysis using CMR were included. As standard method, the manual contouring of RV-short axis planes was performed for the measurement of end-diastolic volume (EDV) and end-systolic volume (ESV). Additionally, two linear measurements in four-chamber views were obtained in systole and diastole basal diameters at the level of tricuspid valve (Dd and Ds) and baso-apical lengths from the center of tricuspid valve to the RV apex (Ld and Ls) were measured for the calculation of RV-EDV = 1.21 × Dd2 × Ld and RV-ESV = 1.21 × Ds 2 × Ls using CPF.

Results:

RV volumes using CPF were slightly higher than those using standard CMR analysis (RV-EDV index 86.2 ± 29.4 mL/m2 and RV-ESV index 51.5 ± 22.5 mL/m2 vs. RV-EDV index 81.7 ± 24.1 mL/m2 and RV-ESV index 44.5 ± 23.2 mL/m2) and RV-EF was lower (RV-EF 41.1 ± 13.5% vs. 48.4 ± 13.7%). Both methods had a strong correlation of RV volumes (ΔRV-EDV index = -4.5 ± 19.0 mL/m2; r = 0.765, p < 0.0001; ΔRV-ESV index = -7.0 ± 14.4 mL/m2; r = 0.801, p < 0.0001).

Conclusions:

Calculations of RV volumes and function using CPF assuming the geometrical model of a truncated cone-rhomboid pyramid anatomy of RV is feasible, with a strong correlation to measurements using standard CMR analysis, and only two systolic and diastolic linear measurements in four-chamber views are needed.