Your browser doesn't support javascript.
loading
Glyoxal-methyl-ethylene sulfonic acid fixative enhances the fixation of cytoskeletal structures for Förster resonance energy transfer measurements.
Kuriyama, Sei; Thasaneeya, Kuboki; Itoh, Go; Kidoaki, Satoru; Tanaka, Masamitsu.
Afiliação
  • Kuriyama S; Department Molecular Medicine & Biochemistry, Akita University Fac. & Grad. Sch. Med, Akita City, Akita, 010-8543, Japan. seikury@med.akita-u.ac.jp.
  • Thasaneeya K; Institute for Materials Chemistry and Engineering, Division Biomolecular Chemistry, Kyushu University, 744 Moto-Oka, Nishi-Ku, Fukuoka, 819-0395, Japan.
  • Itoh G; Department Molecular Medicine & Biochemistry, Akita University Fac. & Grad. Sch. Med, Akita City, Akita, 010-8543, Japan.
  • Kidoaki S; Institute for Materials Chemistry and Engineering, Division Biomolecular Chemistry, Kyushu University, 744 Moto-Oka, Nishi-Ku, Fukuoka, 819-0395, Japan.
  • Tanaka M; Department Molecular Medicine & Biochemistry, Akita University Fac. & Grad. Sch. Med, Akita City, Akita, 010-8543, Japan.
Histochem Cell Biol ; 162(4): 337-347, 2024 Oct.
Article em En | MEDLINE | ID: mdl-38880796
ABSTRACT
Förster resonance energy transfer (FRET) serves as a tool for measuring protein-protein interactions using various sensor molecules. The tension sensor module relies on FRET technology. In our study, this module was inserted within the actinin molecule to measure the surface tension of the cells. Given that the decay curve of FRET efficiency correlates with surface tension increase, precise and accurate efficiency measurement becomes crucial. Among the methods of FRET measurements, FRET efficiency remains the most accurate if sample fixation is successful. However, when cells were fixed with 4% paraformaldehyde (PFA), the actinin-FRET sensor diffused across the cytoplasm; this prompted us to explore fixation method enhancements. Glyoxal fixative has been reported to improve cytoskeletal morphologies compared to PFA. However, it was not known whether glyoxal fits FRET measurements. Glyoxal necessitates an acetic acid solution for fixation; however, acidic conditions could compromise fluorescence stability. We observed that the pH working range of glyoxal fixative aligns closely with MES (methyl-ethylene sulfonic acid) Good's buffer. Initially, we switched the acidic solution for MES buffer and optimized the fixation procedure for in vitro and in vivo FRET imaging. By comparing FRET measurements on hydrogels with known stiffness to tumor nodules in mouse lung, we estimated in vivo stiffness. The estimated stiffness of cancerous tissue was harder than the reported stiffness of smooth muscle. This discovery shed lights on how cancer cells perceive environmental stiffness during metastasis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transferência Ressonante de Energia de Fluorescência / Glioxal Limite: Animals / Humans Idioma: En Revista: Histochem Cell Biol Assunto da revista: CITOLOGIA / HISTOCITOQUIMICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transferência Ressonante de Energia de Fluorescência / Glioxal Limite: Animals / Humans Idioma: En Revista: Histochem Cell Biol Assunto da revista: CITOLOGIA / HISTOCITOQUIMICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão