Your browser doesn't support javascript.
loading
Management of twin reversed arterial perfusion (TRAP) sequence with microwave ablation: A case report and review of the literature.
Stellon, Michael A; Joshi, Devashish S; Beninati, Michael; Antony, Kathleen M; Bohrer, Justin; Hinshaw, J Louis; Monroe, Eric; Winchester, Casey; Lobeck, Inna.
Afiliação
  • Stellon MA; Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Joshi DS; Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Beninati M; Department of Obstetrics and Gynecology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Antony KM; Department of Obstetrics and Gynecology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Bohrer J; Department of Obstetrics and Gynecology, Gunderson Health System, La Crosse, Wisconsin, USA.
  • Hinshaw JL; Department of Interventional Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Monroe E; Department of Interventional Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Winchester C; Center for Perinatal Care, UnityPoint Health Meriter Hospital, Madison, Wisconsin, USA.
  • Lobeck I; Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
J Clin Ultrasound ; 52(8): 1208-1213, 2024 Oct.
Article em En | MEDLINE | ID: mdl-38940580
ABSTRACT
Twin reversed arterial perfusion (TRAP) sequence carries a high mortality risk to the "pump twin." Management involves disrupting blood flow to the acardiac mass. In this case, the pregnant patient presented at 20 weeks 6 days with Stage IIb TRAP Sequence and underwent percutaneous ultrasound-guided microwave ablation (MWA) of the acardiac mass at 21 weeks 0 days. The probe traversed the thorax of the acardiac mass and ablated the confluence of the umbilical vessels. A healthy child was delivered at 33 weeks 5 days gestation. This report demonstrates the utility of MWA in TRAP sequence and describes a novel approach.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ultrassonografia Pré-Natal / Transfusão Feto-Fetal / Micro-Ondas Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: J Clin Ultrasound Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ultrassonografia Pré-Natal / Transfusão Feto-Fetal / Micro-Ondas Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: J Clin Ultrasound Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos