Your browser doesn't support javascript.
loading
Development of temperature-controlled batch and 3-column counter-current protein A system for improved therapeutic purification.
Armstrong, Alexander; Hernandez, Jorge Aranda; Roth, Felix; Bracewell, Daniel G; Farid, Suzanne S; P C Marques, Marco; Goldrick, Stephen.
Afiliação
  • Armstrong A; Advanced Centre for Biochemical Engineering, University College London, United Kingdom.
  • Hernandez JA; Advanced Centre for Biochemical Engineering, University College London, United Kingdom.
  • Roth F; Cell Culture and Fermentation Science, Biopharmaceuticals Development, R&D, AstraZeneca, Cambridge, United Kingdom.
  • Bracewell DG; Advanced Centre for Biochemical Engineering, University College London, United Kingdom.
  • Farid SS; Advanced Centre for Biochemical Engineering, University College London, United Kingdom.
  • P C Marques M; Advanced Centre for Biochemical Engineering, University College London, United Kingdom.
  • Goldrick S; Advanced Centre for Biochemical Engineering, University College London, United Kingdom. Electronic address: s.goldrick@ucl.ac.uk.
J Chromatogr A ; 1730: 465110, 2024 Aug 16.
Article em En | MEDLINE | ID: mdl-38941794
ABSTRACT
Maximizing product quality attributes by optimizing process parameters and performance attributes is a crucial aspect of bioprocess chromatography process design. Process parameters include but are not limited to bed height, eluate cut points, and elution pH. An under-characterized chromatography process parameter for protein A chromatography is process temperature. Here, we present a mechanistic understanding of the effects of temperature on the protein A purification of a monoclonal antibody (mAb) using a commercial chromatography resin for batch and continuous counter-current systems. A self-designed 3D-printed heating jacket controlled the 1 mL chromatography process temperature during the loading, wash, elution, and cleaning-in-place (CIP) steps. Batch loading experiments at 10, 20, and 30 °C demonstrated increased dynamic binding capacity (DBC) with temperature. The experimental data were fit to mechanistic and correlation-based models that predicted the optimal operating conditions over a range of temperatures. These model-based predictions optimized the development of a 3-column temperature-controlled periodic counter-current chromatography (TCPCC) and were validated experimentally. Operating a 3-column TCPCC at 30 °C led to a 47% increase in DBC relative to 20 °C batch chromatography. The DBC increase resulted in a two-fold increase in productivity relative to 20 °C batch. Increasing the number of columns to the TCPCC to optimize for increasing feed concentration resulted in further improvements to productivity. The feed-optimized TCPCC showed a respective two, three, and four-fold increase in productivity at feed concentrations of 1, 5, and 15 mg/mL mAb, respectively. The derived and experimentally validated temperature-dependent models offer a valuable tool for optimizing both batch and continuous chromatography systems under various operating conditions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína Estafilocócica A / Temperatura / Distribuição Contracorrente / Anticorpos Monoclonais Limite: Animals Idioma: En Revista: J Chromatogr A Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína Estafilocócica A / Temperatura / Distribuição Contracorrente / Anticorpos Monoclonais Limite: Animals Idioma: En Revista: J Chromatogr A Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Reino Unido