The Emerging Future of Mobile Audiometry: A Prospective Validation Study of the Mimi Hearing Test Application.
Moazzami, Chloé; Gagnon, Carolanne; Bertrand, Léo; Saliba, Issam; Saliba, Joe.
Afiliação
  • Moazzami C; Department of Internal Medicine.
  • Gagnon C; Division of Otolaryngology-Head and Neck Surgery, Department of Surgery.
  • Bertrand L; Faculty of Pharmacy, Université de Montréal, Montreal, Canada.
  • Saliba I; Division of Otolaryngology-Head and Neck Surgery, Department of Surgery.
  • Saliba J; Division of Otolaryngology-Head and Neck Surgery, Department of Surgery.
Otol Neurotol ; 45(7): 740-744, 2024 Aug 01.
Article em En | MEDLINE | ID: mdl-38942612
ABSTRACT

OBJECTIVE:

The objective of this study is to assess the accuracy of the Mimi Hearing Test (MHT) mobile application in the detection of air conduction (AC) thresholds and in screening for moderate hearing loss. STUDY

DESIGN:

Prospective clinical study.

SETTING:

Tertiary care center. PATIENTS Participants with or without a varying degree of hearing loss, aged 18 years and over, without cognitive impairment and without active otorrhea or earwax impaction at the time of the hearing assessment were included. INTERVENTION Subjects with a ranging severity of hearing loss underwent a conventional in-booth audiogram as well as mobile-based screening with MHT in a quiet room (45.5 dB background noise) on the same day. Both regular over-the-ear and noise-canceling headphones were tested with MHT. MAIN OUTCOME

MEASURES:

Comparisons of AC thresholds between conventional audiometry and mobile-based audiometry at discrete frequencies and with pure-tone averages (PTA) were performed.

RESULTS:

A total of 75 adults (mean age 56.2 yr, 54.7% male) were recruited and 63 used for analysis. Of the thresholds measured with MHT using regular headphones, 44.0% were within 10 dB of the conventional audiogram, compared to 39.3% using noise-canceling headphones. MHT demonstrated best accuracy at high frequencies (4-8 kHz). When screening for moderate hearing loss (PTA >40 dB HL), MHT demonstrated a sensitivity and specificity of 100.0% and 80.2%, respectively.

CONCLUSIONS:

MHT is reliable for identifying moderate hearing loss but lacks precision in detecting thresholds at low frequencies. Noise canceling headphones seem to improve its precision at 4,000 Hz only.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aplicativos Móveis / Perda Auditiva Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Otol Neurotol Assunto da revista: NEUROLOGIA / OTORRINOLARINGOLOGIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aplicativos Móveis / Perda Auditiva Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Otol Neurotol Assunto da revista: NEUROLOGIA / OTORRINOLARINGOLOGIA Ano de publicação: 2024 Tipo de documento: Article