Wireless Device Therapy in Hypertrophic Cardiomyopathy Using the Combination of a Leadless Pacemaker and a Subcutaneous Defibrillator: A Report with 2-year Follow-up of Two Patients.
Milaras, Nikias; Ntalakouras, Ioannis; Archontakis, Stefanos; Dourvas, Panagiotis; Ktenopoulos, Nikolaos; Klogkeri, Tzontatan; Nevras, Vasileios; Sideris, Skevos.
Afiliação
  • Milaras N; Cardiology Department, General Hospital of Athens Hippokrateion, Athens, Greece.
  • Ntalakouras I; Cardiology Department, General Hospital of Athens Hippokrateion, Athens, Greece.
  • Archontakis S; Cardiology Department, General Hospital of Athens Hippokrateion, Athens, Greece.
  • Dourvas P; Cardiology Department, General Hospital of Athens Hippokrateion, Athens, Greece.
  • Ktenopoulos N; Cardiology Department, General Hospital of Athens Hippokrateion, Athens, Greece.
  • Klogkeri T; Cardiology Department, General Hospital of Athens Hippokrateion, Athens, Greece.
  • Nevras V; Cardiology Department, General Hospital of Athens Hippokrateion, Athens, Greece.
  • Sideris S; Cardiology Department, General Hospital of Athens Hippokrateion, Athens, Greece.
J Innov Card Rhythm Manag ; 15(6): 5908-5910, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38948666
ABSTRACT
Cardiac implantable electronic devices (CIEDs) are essential tools in cardiology for tackling rhythm disturbances and have come a long way over the last decades. Technology is shifting toward leadless devices that spare the complications and limitations of traditional intravascular CIEDs. Herein, we report the simultaneous implantation of a leadless pacemaker (LP) and a subcutaneous implantable cardioverter-defibrillator (S-ICD) in two patients with hypertrophic cardiomyopathy, as well as their 2-year follow-up results, while explaining the preventive measures taken to steer around unwanted device interaction. Implantation of an S-ICD with an LP is reserved for unique cases but is a feasible approach when there is a contraindication for intravascular CIED implantation. Furthermore, this technique may be used in younger patients with cardiomyopathies in whom multiple generator replacements are expected, along with their known adverse effects.