Your browser doesn't support javascript.
loading
Coefficient of spatial variance of choroidal thickness on swept-source optical coherence tomography in healthy eyes.
Jiang, Zehua; Lin, Tian; Lin, Aidi; Lin, Jianwei; Chen, Shirong; Zhou, Lingling; Chen, Haoyu.
Afiliação
  • Jiang Z; Joint Shantou International Eye Centre of Shantou University and the Chinese University of Hong Kong, Shantou, Guangdong, China.
  • Lin T; Medical College, Shantou University, Shantou, Guangdong, China.
  • Lin A; Joint Shantou International Eye Centre of Shantou University and the Chinese University of Hong Kong, Shantou, Guangdong, China.
  • Lin J; Medical College, Shantou University, Shantou, Guangdong, China.
  • Chen S; Joint Shantou International Eye Centre of Shantou University and the Chinese University of Hong Kong, Shantou, Guangdong, China.
  • Zhou L; Medical College, Shantou University, Shantou, Guangdong, China.
  • Chen H; Joint Shantou International Eye Centre of Shantou University and the Chinese University of Hong Kong, Shantou, Guangdong, China.
Int Ophthalmol ; 44(1): 318, 2024 Jul 08.
Article em En | MEDLINE | ID: mdl-38972925
ABSTRACT

PURPOSE:

This study aims to introduce the coefficient of spatial variance of choroidal thickness to describe the choroidal variation and investigate its associated factors in healthy eyes.

METHODS:

This retrospective cross-sectional study included 1031 eyes from 1031 subjects who received a swept-source optical coherence tomography examination. The mean choroidal thickness in the macular 6 × 6 mm region and 900 subregions of 0.2 × 0.2 mm were computed using the embedded algorithm. Before analysis, potential segmentation and magnification errors were corrected. The coefficient of spatial variance was defined as the standard deviation divided by the mean (multiplied by 100%) of the choroidal thicknesses across 900 grids. Potential factors associated with the coefficient of spatial variance were assessed using multiple linear regression.

RESULTS:

The mean choroidal thickness of the entire 6 × 6 mm macular region was 204.50 ± 72.88 µm. The mean coefficient of spatial variance was 26.58 ± 8.24%, ranging from 11.00 to 61.58%. Statistical analysis revealed that the means choroidal thickness (ß = - 0.08, R2 = 0.42, p < 0.001) and anterior chamber depth (ß = - 2.39, R2 = 0.05, p = 0.06) were associated with the coefficient of spatial variance.

CONCLUSION:

Our study first incorporated the coefficient of spatial variance to represent the spatial variation of the choroidal thickness and observed that the greater thinning of the choroid is correlated with a more pronounced spatial variation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corioide / Tomografia de Coerência Óptica Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Int Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corioide / Tomografia de Coerência Óptica Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Int Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China