Your browser doesn't support javascript.
loading
Serum matrix metalloproteinase-7 for discriminating biliary atresia: a diagnostic accuracy and validation study.
Jiang, Jingying; Dong, Rui; Du, Min; Chen, Gong; Yang, Jingyun; Xie, Xinbao; Yang, Yifan; Yan, Weili; Zheng, Shan.
Afiliação
  • Jiang J; Department of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, Key Laboratory of Neonatal Disease, Children's Hospital of Fudan University, Ministry of Health, 399 Wan Yuan Road, Shanghai, 201102, China.
  • Dong R; Department of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, Key Laboratory of Neonatal Disease, Children's Hospital of Fudan University, Ministry of Health, 399 Wan Yuan Road, Shanghai, 201102, China.
  • Du M; Department of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, Key Laboratory of Neonatal Disease, Children's Hospital of Fudan University, Ministry of Health, 399 Wan Yuan Road, Shanghai, 201102, China.
  • Chen G; Department of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, Key Laboratory of Neonatal Disease, Children's Hospital of Fudan University, Ministry of Health, 399 Wan Yuan Road, Shanghai, 201102, China.
  • Yang J; Rush Alzheimer's Disease Center, Rush University Medical Center, Chicago, IL, USA.
  • Xie X; Department of Neurological Sciences, Rush University Medical Center, Chicago, IL, USA.
  • Yang Y; Department of Hepatology, Children's Hospital of Fudan University, 399 Wan Yuan Road, Shanghai, 201102, China.
  • Yan W; Department of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, Key Laboratory of Neonatal Disease, Children's Hospital of Fudan University, Ministry of Health, 399 Wan Yuan Road, Shanghai, 201102, China.
  • Zheng S; Department of Clinical Epidemiology, Clinical Trial Unit, Children's Hospital of Fudan University, 399 Wan Yuan Road, Shanghai, 201102, China. yanwl@fudan.edu.cn.
J Transl Med ; 22(1): 636, 2024 Jul 08.
Article em En | MEDLINE | ID: mdl-38978022
ABSTRACT

BACKGROUND:

Prompt and precise differential diagnosis of biliary atresia (BA) among cholestatic patients is of great importance. Matrix metalloproteinase-7 (MMP-7) holds great promise as a diagnostic marker for BA. This study aimed to investigate the accuracy of age-specific serum MMP-7 for discriminating BA from other cholestatic pediatric patients.

METHODS:

This was a single center diagnostic accuracy and validation study including both retrospective and prospective cohorts. Serum MMP-7 concentrations were measured using an ELISA kit, the trajectory of which with age was investigated in a healthy infants cohort aged 0 to 365 days without hepatobiliary diseases (n = 284). Clinical BA diagnosis was based on intraoperative cholangiography and subsequent histological examinations. The diagnostic accuracy of age-specific cutoffs of serum MMP-7 were assessed in a retrospective cohort of cholestatic patients (n = 318, with 172 BA) and validated in a prospective cohort (n = 687, including 395 BA).

RESULTS:

The MMP-7 concentration declines non-linearly with age, showing higher levels in healthy neonates as well as higher cutoff value in neonatal cholestasis. The area under the ROC curve (AUROC) was 0.967 (95% confidence interval [CI] 0.946-0.988) for the retrospective cohort, and the cutoff of 18 ng/mL yielded 93.0% (95%CI 88.1-96.3%), 93.8% (95%CI 88.6-97.1%), 94.7% (95%CI 90.1-97.5%), and 91.9% (95%CI 86.4-95.8%) for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), respectively. The performance of MMP-7 was successfully validated in the larger prospective cohort, resulting in a diagnostic sensitivity of 95.9% (379/395; 95% CI 93.5-97.7%), a specificity of 87.3% (255/292; 95% CI 83.0-90.9%), a PPV of 91.1% (379/416; 95% CI 87.9-93.7%), and a NPV of 94.1% (255/271; 95% CI 90.6-96.6%), respectively. Besides, higher cutoff value of 28.1 ng/mL achieved the best sensitivity, specificity, PPV, and NPV for infants aged 0-30 days, which was 86.4% (95% CI 75.0-94.0%), 95.5% (95% CI 77.2-99.9%), 98.1% (95% CI 89.7-100%), and 72.4% (95% CI 52.8-87.3%), respectively.

CONCLUSIONS:

The serum MMP-7 is accurate and reliable in differentiating BA from non-BA cholestasis, showing its potential application in the diagnostic algorithm for BA and significant role in the future research regarding pathogenesis of BA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Atresia Biliar / Curva ROC / Metaloproteinase 7 da Matriz Limite: Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Revista: J Transl Med Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Atresia Biliar / Curva ROC / Metaloproteinase 7 da Matriz Limite: Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Revista: J Transl Med Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China