ABSTRACT
Spinal cord stress and strain contribute to degenerative cervical myelopathy (DCM), while cervical kyphosis is known to negatively impact surgical outcomes. In DCM, the relationship between spinal cord biomechanics, sagittal alignment, and cord compression is not well understood. Quantifying this relationship can guide surgical strategies. A previously validated three-dimensional finite element model of the human cervical spine with spinal cord was used. Three models of cervical alignment were created lordosis (C2-C7 Cobb angle 20°), straight (0°), and kyphosis (- 9°). C5-C6 spinal stenosis was simulated with ventral disk protrusions, reducing spinal canal diameters to 10 mm, 8 mm, and 6 mm. Spinal cord pre-stress and pre-strain due to alignment and compression were quantified. Cervical flexion and extension were simulated with a pure moment load of 2 Nm. The Von Mises stress and maximum principal strain of the whole spinal cord were calculated during neck motion and the relationship between spinal cord biomechanics, alignment, and compression was analyzed using linear regression analysis. Spinal cord pre-stress and pre-strain were greatest with kyphosis (7.53 kPa, 5.4%). Progressive kyphosis and stenosis were associated with an increase in spinal cord stress (R2 = 0.99) and strain (R2 = 0.99). Cervical kyphosis was associated with greater spinal cord stress and strain during neck flexion-extension and the magnitude of difference increased with increasing stenosis. Cervical kyphosis increases baseline spinal cord stress and strain. Incorporating sagittal alignment with compression to calculate spinal cord biomechanics is necessary to accurately quantify spinal stress and strain during neck flexion and extension.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Idioma:
En
Revista:
Biomech Model Mechanobiol
Assunto da revista:
ENGENHARIA BIOMEDICA
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Estados Unidos