Your browser doesn't support javascript.
loading
Superior vena cava isolation using a pentaspline pulsed-field ablation catheter: feasibility and safety in patients undergoing atrial fibrillation catheter ablation.
Ollitrault, Pierre; Chaumont, Corentin; Font, Jonaz; Manninger, Martin; Conti, Sergio; Matusik, Pawel T; Mulder, Bart A; Ferchaud, Virginie; Pellissier, Arnaud; Al Khoury, Mayane; Milliez, Paul; Champ-Rigot, Laure; Anselme, Frédéric.
Afiliação
  • Ollitrault P; Electrophysiology Unit, Department of Cardiology, Regional University Hospital, Avenue de la Côte de Nacre, 14000 Caen, France.
  • Chaumont C; Department of Cardiology, Rouen University Medical Center, Rue de Germont, 76031 Rouen, France.
  • Font J; Electrophysiology Unit, Department of Cardiology, Regional University Hospital, Avenue de la Côte de Nacre, 14000 Caen, France.
  • Manninger M; Department of Cardiology, Pôle de Formation et de Recherche en Santé, Rue des Rochambelles, 14000 Caen, France.
  • Conti S; Division of Cardiology, Department of Internal Medical, Graz University Medical Center, Graz, Austria.
  • Matusik PT; Department of Cardiology, ARNAS Civico Hospital, Palermo, Italy.
  • Mulder BA; Department of Cardiology, St. John Paul II Hospital, Pradnicka 80, 31-202 Kraków, Poland.
  • Ferchaud V; Institute of Cardiology, Faculty of Medicine, Jagiellonian University Medical College, Pradnicka 80, 31-202 Kraków, Poland.
  • Pellissier A; Department of Cardiology, Groningen University Medical Center, Groningen, The Netherlands.
  • Al Khoury M; Electrophysiology Unit, Department of Cardiology, Regional University Hospital, Avenue de la Côte de Nacre, 14000 Caen, France.
  • Milliez P; Electrophysiology Unit, Department of Cardiology, Regional University Hospital, Avenue de la Côte de Nacre, 14000 Caen, France.
  • Champ-Rigot L; Electrophysiology Unit, Department of Cardiology, Regional University Hospital, Avenue de la Côte de Nacre, 14000 Caen, France.
  • Anselme F; Electrophysiology Unit, Department of Cardiology, Regional University Hospital, Avenue de la Côte de Nacre, 14000 Caen, France.
Europace ; 26(7)2024 Jul 02.
Article em En | MEDLINE | ID: mdl-39082719
ABSTRACT

AIMS:

Superior vena cava (SVC) isolation during atrial fibrillation catheter ablation is limited by the risk of collateral damage to the sinus node and/or the phrenic nerve. Due to its tissue-specificity, we hypothesized the feasibility and safety of pulsed-field ablation (PFA)-based SVC isolation. METHODS AND

RESULTS:

One hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (±posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phrenic nerve palsy at the end of the procedure and at hospital discharge. Transient high-degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred.

CONCLUSION:

SVC isolation using a pentaspline PFA catheter is feasible and safe.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Veia Cava Superior / Estudos de Viabilidade / Ablação por Cateter Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Veia Cava Superior / Estudos de Viabilidade / Ablação por Cateter Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: França