Your browser doesn't support javascript.
loading
An eight-year retrospective study on the clinical outcomes of laser surface-treated implants.
Leesungbok, Richard; Hong, Sung Ok; Lee, Suk-Won; Htay, Phyo Ei Ei; Choi, Joseph Junesirk; Park, Jung Jin.
Afiliação
  • Leesungbok R; Department of Biomaterials and Prosthodontics, Kyung Hee University Dental Hospital at Gangdong, Kyung Hee University College of Dentistry, Dongnamro 892, Gangdong-Gu, Seoul, 05278, Republic of Korea. barcelonaw@naver.com.
  • Hong SO; Professor Emeritus, Kyung Hee University School of Dentistry, Seoul, South Korea. barcelonaw@naver.com.
  • Lee SW; Department of Oral and Maxillofacial Surgery, Kyung Hee University Dental Hospital at Gangdong, Kyung Hee University College of Dentistry, Dongnamro 892, Gangdong-Gu, Seoul, 05278, Republic of Korea. catherine.so.hong.sleepdoc@gmail.com.
  • Htay PEE; Department of Biomaterials and Prosthodontics, Kyung Hee University Dental Hospital at Gangdong, Kyung Hee University College of Dentistry, Dongnamro 892, Gangdong-Gu, Seoul, 05278, Republic of Korea.
  • Choi JJ; Department of Biomaterials and Prosthodontics, Kyung Hee University Dental Hospital at Gangdong, Kyung Hee University College of Dentistry, Dongnamro 892, Gangdong-Gu, Seoul, 05278, Republic of Korea.
  • Park JJ; Department of Biomaterials and Prosthodontics, Kyung Hee University Dental Hospital at Gangdong, Kyung Hee University College of Dentistry, Dongnamro 892, Gangdong-Gu, Seoul, 05278, Republic of Korea.
Int J Implant Dent ; 10(1): 38, 2024 Aug 05.
Article em En | MEDLINE | ID: mdl-39101986
ABSTRACT

PURPOSE:

To retrospectively evaluate peri-implant bone loss and health status associated with the long-term use of laser surface-treated implants.

METHODS:

For control study, total of 23 titanium ASTM F136 grade 23 implants were placed in the edentulous molar area of the mandible. When the Implant Stability Quotient (ISQ) ≥ 70 and insertion torque value (ITV) ≥ 35-50 Ncm at the insertion site, an immediate provisional restoration was connected to the implant within a week after surgery. The definitive restorations were placed 2 months after surgery for all implants. 13 implants were immediately loaded, while 10 implants were conventionally loaded. For comparative study, Radiographs were taken from third years for and then annually for the subsequent eight years to monitor marginal bone loss.

RESULTS:

After eight year of implant installation, the average change in vertical bone loss was 0.009 mm (P < 0.001), while the average change in horizontal bone loss 8 year after implant placement was 0.026 mm (P < 0.001). The mean marginal bone loss was < 0.2 mm on average.

CONCLUSIONS:

In this retrospective study, laser-treated implants exhibit a low rate of bone absorption around the implants.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Perda do Osso Alveolar Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Implant Dent Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Perda do Osso Alveolar Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Implant Dent Ano de publicação: 2024 Tipo de documento: Article