Your browser doesn't support javascript.
loading
Hollow Fiber-in-Syringe Equilibrium Sampling Through Supported-Liquid Membrane for Evaluation of Drug-Plasma Binding.
Barri, Thaer; Ramzi, Ruba; Idkaidek, Nasir M; Al-Hashimi, Nabil N; Al-Akayleh, Faisal; A Ali Agha, Ahmed S.
Afiliação
  • Barri T; Department of Chemistry, Faculty of Arts & Sciences, University of Petra, P. O. Box 961343, Queen Alia Airport Street, Amman, 11196, Jordan.
  • Ramzi R; Department of Pharmaceutics & Pharmaceutical Technology, Faculty of Pharmacy, University of Petra, P. O. Box 961343, Queen Alia Airport Street, Amman, 11196, Jordan.
  • Idkaidek NM; Department of Pharmaceutics & Pharmaceutical Technology, Faculty of Pharmacy, University of Petra, P. O. Box 961343, Queen Alia Airport Street, Amman, 11196, Jordan.
  • Al-Hashimi NN; Department of Pharmaceutical Chemistry, Faculty of Pharmaceutical Sciences, the Hashemite University, P.O. Box 330127, Al-Zarqa, 13133,Jordan.
  • Al-Akayleh F; Department of Pharmaceutics & Pharmaceutical Technology, Faculty of Pharmacy, University of Petra, P. O. Box 961343, Queen Alia Airport Street, Amman, 11196, Jordan.
  • A Ali Agha AS; Department of Pharmaceutics & Pharmaceutical Technology, Faculty of Pharmacy, University of Petra, P. O. Box 961343, Queen Alia Airport Street, Amman, 11196, Jordan.
Bioanalysis ; : 1-12, 2024 Aug 08.
Article em En | MEDLINE | ID: mdl-39115045
ABSTRACT

Aim:

The aim was to evaluate drug-plasma binding (DPB).by employing Hollow Fiber-in-Syringe Equilibrium Sampling Through Supported Liquid Membrane (HFiS ESTSLM) and RP-HPLC analysis. Materials &

methods:

HFiS ESTSLM and RP-HPLC were used to evaluate DPB of three weak basic drugs (Metoprolol, Diphenhydramine, and Sildenafil) with differing hydrophilicity and binding ability to blood plasma.

Results:

The results exhibited an increasing drug-dependent magnitude of DPB for the three model drugs. This trend of DPB confirmed that HFiS ESTSLM has the required sensitivity for determining DPB of the drugs. The DPB was drug concentration-dependent within the tested drug concentration range, especially at high concentration.

Conclusion:

HFiS ESTSLM and RP-HPLC offered a simple, easy and cost-effective procedure to evaluate DPB of these basic drugs.
[Box see text].
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioanalysis Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Jordânia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioanalysis Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Jordânia