Your browser doesn't support javascript.
loading
[Structural Design and Analysis of Portable Intelligent Wheelchair for Knee Rehabilitation].
Ma, Dongmei; Wang, Jingyan; Pan, Liming; Chen, Jinshi; Chu, Tianyue; Huang, Lei; Yin, Baoyue; Xu, Xin.
Afiliação
  • Ma D; The First Hospital of Jilin University, Changchun, 130021.
  • Wang J; School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025.
  • Pan L; The First Hospital of Jilin University, Changchun, 130021.
  • Chen J; School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025.
  • Chu T; The First Hospital of Jilin University, Changchun, 130021.
  • Huang L; The First Hospital of Jilin University, Changchun, 130021.
  • Yin B; The First Hospital of Jilin University, Changchun, 130021.
  • Xu X; The First Hospital of Jilin University, Changchun, 130021.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(4): 445-450, 2024 Jul 30.
Article em Zh | MEDLINE | ID: mdl-39155261
ABSTRACT

Objective:

In order to address the issues of inconvenience, high medical costs, and lack of universality associated with traditional knee rehabilitation equipment, a portable intelligent wheelchair for knee rehabilitation was designed in this study.

Methods:

Based on the analysis of the knee joint's structure and rehabilitation mechanisms, an electric pushrod-driven rehabilitation institution was developed. A multi-functional module was designed with a modular approach, and the control of the wheelchair body and each functional module was implemented using an STM32 single-chip microcomputer. A three-dimensional model was established using SolidWorks software. In conjunction with Adams and Ansys simulation software, kinematic and static analyses were conducted on the knee joint rehabilitation institution and its core components. A prototype was constructed to verify the equipment's actual performance.

Results:

According to the prototype testing, the actual range of motion for the knee joint swing rod is 15.1°~88.9°, the angular speed of the swing rod ranges from -7.9 to 8.1°/s, the angular acceleration of the swing rod varies from -4.2 to 1.6°/s², the thrust range of the electric pushrod is -82.6 to 153.1 N, and the maximum displacement of the load pedal is approximately 1.7 mm, with the leg support exhibiting a maximum deformation of about 1.5 mm.

Conclusion:

The intelligent knee joint rehabilitation wheelchair meets the designed functions and its actual performance aligns with the design criteria, thus validating the rationality and feasibility of the structural design.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cadeiras de Rodas / Desenho de Equipamento / Articulação do Joelho Limite: Humans Idioma: Zh Revista: Zhongguo Yi Liao Qi Xie Za Zhi Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cadeiras de Rodas / Desenho de Equipamento / Articulação do Joelho Limite: Humans Idioma: Zh Revista: Zhongguo Yi Liao Qi Xie Za Zhi Ano de publicação: 2024 Tipo de documento: Article