Your browser doesn't support javascript.
loading
Binary Soong grading as a predictor for flexor pollicis longus tendon rupture after distal radial fracture fixation: a retrospective study.
Dijkmans, Anjuli L; Laane, Charlotte L E; Fernandez Dell'Oca, Alberto; Jupiter, Jesse B; Garg, Rohit; Bhashyam, Abhiram R.
Afiliação
  • Dijkmans AL; Hand and Upper Extremity Service, Division of Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Laane CLE; Hand and Upper Extremity Service, Division of Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Fernandez Dell'Oca A; Department of Surgery, Trauma Research Unit, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands.
  • Jupiter JB; Department of Orthopedics, Hospital Britanico Montevideo, Montevideo, Uruguay.
  • Garg R; Hand and Upper Extremity Service, Division of Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Bhashyam AR; Hand and Upper Extremity Service, Division of Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
J Hand Surg Eur Vol ; : 17531934241258312, 2024 Aug 22.
Article em En | MEDLINE | ID: mdl-39169760
ABSTRACT
This retrospective cohort study evaluates the concordance between Soong grades classified from radiographs and computed tomography (CT) scans and whether a Soong grade ≥1 is associated with flexor pollicis longus (FPL) injury and reoperation incidence. We included 181 patients with 185 dorsally displaced distal radial fractures treated with anterior locking plates. For the analysis of binary Soong grades, grade 0 was compared with grades 1 and 2. A moderate correlation was found between Soong grades on radiographs and CT scans (MCC 0.66). FPL injury occurred in 3% (6/185) and reoperation in 15% (28/185) of cases. There was no statistically significant difference between Soong grades when correlated with the incidence of FPL injury or reoperation, but no patients with a Soong grade 0 had an FPL injury. Binary Soong grading is non-inferior in predictive value and has a better correlation between radiographs and CT scans. Using the Soong classification as a binary system may be easier than a ternary system in clinical practice.Level of evidence IV.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Hand Surg Eur Vol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Hand Surg Eur Vol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos