An Optical Device Based on a Chemical Chip and Surface Plasmon Platform for 2-Furaldehyde Detection in Insulating Oil.
De Maria, Letizia; Arcadio, Francesco; Gabetta, Giuseppe; Merli, Daniele; Alberti, Giancarla; Zeni, Luigi; Cennamo, Nunzio; Pesavento, Maria.
Afiliação
  • De Maria L; RSE S.p.A., Via Rubattino 54, 20134 Milan, Italy.
  • Arcadio F; Department of Engineering, University of Campania L. Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
  • Gabetta G; CESI S.p.A., Via Rubattino 54, 20134 Milan, Italy.
  • Merli D; Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy.
  • Alberti G; Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy.
  • Zeni L; Department of Engineering, University of Campania L. Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
  • Cennamo N; Department of Engineering, University of Campania L. Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
  • Pesavento M; Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy.
Sensors (Basel) ; 24(16)2024 Aug 14.
Article em En | MEDLINE | ID: mdl-39204956
ABSTRACT
2-Furaldehyde (2-FAL) is one of the main by-products of the degradation of hemicellulose, which is the solid material of the oil-paper insulating system of oil-filled transformers. For this reason, it has been suggested as a marker of the degradation of the insulating system; sensing devices for 2-FAL analysis in a wide concentration range are of high interest in these systems. An optical sensor system is proposed; this consists of a chemical chip, able to capture 2-FAL from the insulating oil, coupled with a surface plasmon resonance (SPR) probe, both realized on multimode plastic optical fibers (POFs). The SPR platform exploits gold nanofilm or, alternatively, a double layer of gold and silicon oxide to modulate the sensor sensitivity. The capturing chip is always based on the same molecularly imprinted polymer (MIP) as a receptor specific for 2-FAL. The system with the SPR probe based on a gold nanolayer had a higher sensitivity and a lower detection limit of fractions of µg L-1. Instead, the SPR probe, based on a double layer (gold and silicon oxide), has a lower sensitivity with a worse detection limit, and it is suitable for the detection of 2-FAL at concentrations of 0.01-1 mg L-1.