Your browser doesn't support javascript.
loading
Cone-beam CT landmark detection for measuring basal bone width: a retrospective validation study.
Dai, Juan; Guo, Xinge; Zhang, Hongyuan; Xie, Haoyu; Huang, Jiahui; Huang, Qiangtai; Huang, Bingsheng.
Afiliação
  • Dai J; Department of Stomatology, Shenzhen University General Hospital, Shenzhen University Clinical Medical Academy, Xueyuan Avenue, Nanshan District, Shenzhen, Guangdong, 518055, China.
  • Guo X; Medical AI Lab, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China.
  • Zhang H; Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China.
  • Xie H; Medical AI Lab, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China.
  • Huang J; Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China.
  • Huang Q; Medical AI Lab, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China.
  • Huang B; Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China.
BMC Oral Health ; 24(1): 1091, 2024 Sep 14.
Article em En | MEDLINE | ID: mdl-39277722
ABSTRACT

BACKGROUND:

Accurate assessment of basal bone width is essential for distinguishing individuals with normal occlusion from patients with maxillary transverse deficiency who may require maxillary expansion. Herein, we evaluated the effectiveness of a deep learning (DL) model in measuring landmarks of basal bone width and assessed the consistency of automated measurements compared to manual measurements.

METHODS:

Based on the U-Net algorithm, a coarse-to-fine DL model was developed and trained using 80 cone-beam computed tomography (CBCT) images. The model's prediction capabilities were validated on 10 CBCT scans and tested on an additional 34. To evaluate the performance of the DL model, its measurements were compared with those taken manually by one junior orthodontist using the concordance correlation coefficient (CCC).

RESULTS:

It took approximately 1.5 s for the DL model to perform the measurement task in only CBCT images. This framework showed a mean radial error of 1.22 ± 1.93 mm and achieved successful detection rates of 71.34%, 81.37%, 86.77%, and 91.18% in the 2.0-, 2.5-, 3.0-, and 4.0-mm ranges, respectively. The CCCs (95% confidence interval) of the maxillary basal bone width and mandibular basal bone width distance between the DL model and manual measurement for the 34 cases were 0.96 (0.94-0.97) and 0.98 (0.97-0.99), respectively.

CONCLUSION:

The novel DL framework developed in this study improved the diagnostic accuracy of the individual assessment of maxillary width. These results emphasize the potential applicability of this framework as a computer-aided diagnostic tool in orthodontic practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Feixe Cônico / Pontos de Referência Anatômicos / Maxila Limite: Adolescent / Adult / Female / Humans / Male Idioma: En Revista: BMC Oral Health Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Feixe Cônico / Pontos de Referência Anatômicos / Maxila Limite: Adolescent / Adult / Female / Humans / Male Idioma: En Revista: BMC Oral Health Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China