Your browser doesn't support javascript.
loading
Spectrophotometric determination of clonogenic capacity of leukemic cells in a semisolid microtiter culture system.
Schweitzer, C M; van de Loosdrecht, A A; Jonkhoff, A R; Ossenkoppele, G J; Huijgens, P C; Dräger, A M; Broekhoven, M G; Langenhuijsen, M M.
Afiliação
  • Schweitzer CM; Department of Hematology, Free University Hospital, Amsterdam, The Netherlands.
Exp Hematol ; 21(4): 573-8, 1993 Apr.
Article em En | MEDLINE | ID: mdl-8462666
ABSTRACT
In this study we describe a semiautomated clonogenic assay in which human leukemic cell lines (U937 and HL60) are cultured in a semisolid 96-well microtiter culture system and clonogenicity is measured spectrophotometrically in a 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT)-assay and sulforhodamine (SRB)-assay. Culture medium with 0.6% (wt/vol) methylcellulose and 10% (vol/vol) fetal calf serum (FCS) appeared to provide optimal culture conditions with a low background absorbance in both colorimetric assays and an optimal linearity between cell number and optical density (OD). An excellent correlation between clonogenic growth of U937 and HL60 cells in the conventional colony-forming unit assay (CFU-assay) and the microtiter CFU-assay was observed. The value of this microtiter CFU-assay was assessed by modulating U937 and HL60 cells with either 1,25(OH)2D3 or cytosine arabinoside (Ara-C). Additionally, the number of living cells was quantitated spectrophotometrically in both MTT- and SRB-assays. Results obtained by either method did not differ significantly (p < 0.001). In liquid culture, however, significantly (p < 0.001) less reduction of cellular growth was observed with 1,25(OH)2D3-modified cells. No significant differences between the liquid and semisolid assay systems could be observed in the presence of Ara-C. In conclusion, the microtiter clonogenic assay provides a rapid and objective way of measuring clonogenic capacity of (leukemic) cell lines. The semiautomated clonogenic assay will be useful to assess large series of immune modulations and/or cytostatic drug screening.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Células Tumorais Cultivadas Limite: Humans Idioma: En Revista: Exp Hematol Ano de publicação: 1993 Tipo de documento: Article País de afiliação: Holanda
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Células Tumorais Cultivadas Limite: Humans Idioma: En Revista: Exp Hematol Ano de publicação: 1993 Tipo de documento: Article País de afiliação: Holanda