Your browser doesn't support javascript.
loading
Prevention of recurrent atrial fibrillation with chronic dual-site right atrial pacing.
Saksena, S; Prakash, A; Hill, M; Krol, R B; Munsif, A N; Mathew, P P; Mehra, R.
Afiliação
  • Saksena S; Cardiac Arthythmia and Pacemaker Service, Eastern Heart Institute, Passaic, New Jersey, USA.
J Am Coll Cardiol ; 28(3): 687-94, 1996 Sep.
Article em En | MEDLINE | ID: mdl-8772757
ABSTRACT

OBJECTIVES:

We investigated 1) the feasibility, safety and efficacy of multisite right atrial pacing for prevention of atrial fibrillation (AF); and 2) the ability of atrial pacing in single- and dual-site modes to increase arrhythmia-free intervals in patients with drug-refractory AF.

BACKGROUND:

We recently developed and applied a novel technique of dual-site right atrial pacing in an unselected group of consecutive patients with AF requiring demand pacing. A prospective crossover study design was used to evaluate single- and dual-site right atrial pacing modes.

METHODS:

The frequency of AF during the 3 months before pacemaker implantation was analyzed. Consecutive consenting patients underwent insertion of two atrial leads and one ventricular lead with a DDDR pulse generator. Patients were placed in a dual-site pacing mode for the first 3 months and subsequently mode switched to single site pacing for 3 months. Mode switching was repeated at 6-month intervals thereafter.

RESULTS:

Atrial pacing resulted in a marked decline in AF recurrences (p < 0.001). During dual-site pacing with an optimal drug regimen, there was no AF recurrence in any patient compared with five recurrences in 12 patients during single-site pacing (p = 0.03). The mean (+/-SD) arrhythmia-free interval before pacing (14 +/- 14 days) was prolonged with dual- (89 +/- 7 days, p < 0.0001) and single-site pacing (76 +/- 27 days, p < 0.0001). Symptomatic AF episodes showed a declining trend during dual- and single-site pacing compared with those during the preimplantation period (p = 0.10). Mean antiarrhythmic drug use for all classes declined from 4 +/- 1.9 drugs before implantation to 1.5 +/- 0.5 (p < 0.01) drugs after implantation. Twelve (80%) of 15 patients remained in atrial paced rhythm at 13 +/- 3 months.

CONCLUSIONS:

We conclude that multisite right atrial pacing is feasible, effective and safe for long-term application. Atrial pacing significantly prolongs arrhythmia-free intervals in patients with drug-refractory paroxysmal AF. Dual-site right atrial pacing may offer additional benefits and should be considered either as the primary mode or in patients unresponsive to single-site pacing.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Estimulação Cardíaca Artificial Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Am Coll Cardiol Ano de publicação: 1996 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Estimulação Cardíaca Artificial Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Am Coll Cardiol Ano de publicação: 1996 Tipo de documento: Article País de afiliação: Estados Unidos