["Banding" of the venous side of an arteriovenous fistula for hemodialysis complicated with steal syndrome: a clinical case]. / "Banding" del versante venoso di fistola artero-venosa per emodialisi complicata da sindrome di furto periferico: un caso clinico.
Ann Ital Chir
; 68(2): 241-3, 1997.
Article
em It
| MEDLINE
| ID: mdl-9290017
ABSTRACT
The duration of an arteriovenous fistula has a limit. In fact there are some complications that compromise a good working of them. We have dealed on of these complications, a steal syndrome of an omero-cephalic fistula by a simple operation of "banding" using a ring of Teflon around the arterialized vein getting a good clinical result with a good preservation of the blood flow trans-fistula.