Your browser doesn't support javascript.
loading
Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome.
Rau, T; Schofer, J; Schlüter, M; Seidensticker, A; Berger, J; Mathey, D G.
Afiliação
  • Rau T; Center for Cardiology Othmarschen, University Hospital Eppendorf, Hamburg, Germany.
J Am Coll Cardiol ; 31(2): 275-80, 1998 Feb.
Article em En | MEDLINE | ID: mdl-9462567
OBJECTIVES: This study was designed to determine and assess factors predictive of the intermediate-term outcome of stenting of nonacute total coronary occlusions. BACKGROUND: Balloon angioplasty of recanalized coronary occlusions is associated with a combined restenosis/reocclusion rate of up to 65%. Adjunctive stenting holds the potential to reduce this rate significantly. However, variables affecting the late angiographic outcome of coronary stenting in the setting of a total occlusion have not been elucidated sufficiently. METHODS: Coronary stenting was performed in 143 consecutive patients with a nonacute total occlusion; 120 of these patients (84%), with a total of 121 occlusions, underwent repeat angiography within 6 months and comprised the study group. High pressure stent implantation aimed to cover the site of the occlusion as well as adjacent diameter stenoses > or = 70% and all possibly induced dissections. Pertinent angiographic and procedural variables obtained at the time of the intervention were entered into a multivariate logistic regression analysis model to assess their influence on the angiographic outcome at follow-up. RESULTS: Mean preinterventional reference lumen diameter for the 121 vessels was 2.99 +/- 0.53 mm (mean +/- SD); occlusion length ranged from 4 to 44 mm (median of 7.7). After balloon angioplasty, dissections were found in 80% of patients. Lesions were covered with stents a median of 16 mm in length (range 8 to 53). The minimal lumen diameter (MLD) achieved after stenting was 2.89 +/- 0.48 mm. After a median follow-up period of 4.5 months, mean MLD was assessed at 1.91 +/- 0.90 mm, corresponding to a loss index of 0.34 +/- 0.31. There were 27 vessels with a nonocclusive restenosis > or = 50% and 8 with a reocclusion, for a combined restenosis/reocclusion rate of 29%. Factors found to adversely influence angiographic outcome were a post-stenting MLD < or = 2.54 mm, a stented vessel segment length > 16 mm, a balloon/vessel diameter ratio for final stent expansion < or = 1.00 and the presence of a dissection after balloon angioplasty. CONCLUSIONS: Compared with previous reports on stand-alone balloon angioplasty, stenting of nonacute total coronary occlusions lowers the 6-month restenosis/reocclusion rate to approximately 30%. The late procedural outcome is independently and statistically significantly influenced by the MLD after stenting, the length of the stented vessel segment, the balloon/vessel diameter ratio for final stent expansion and the incidence of dissections after balloon angioplasty.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Stents / Angiografia Coronária / Doença das Coronárias Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: J Am Coll Cardiol Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Stents / Angiografia Coronária / Doença das Coronárias Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: J Am Coll Cardiol Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Alemanha