Your browser doesn't support javascript.
loading
Technetium-99m-ECD SPECT fails to show focal hyperemia of acute herpes encephalitis.
Fazekas, F; Roob, G; Payer, F; Kapeller, P; Strasser-Fuchs, S; Aigner, R M.
Afiliação
  • Fazekas F; Department of Neurology, MR Institute, Graz, Austria.
J Nucl Med ; 39(5): 790-2, 1998 May.
Article em En | MEDLINE | ID: mdl-9591576
ABSTRACT
This is a case of herpes simplex encephalitis (HSE) examined with 99mTc-ethyl cysteinate dimer (ECD) and 99mTc-hexamethyl propyleneamine oxime (HMPAO) SPECT. Static images obtained with 99mTc-ECD showed a reduced tracer uptake of the temporal lobe but focal hyperactivity using 99mTc-HMPAO. Dynamic images indicated regional increase of cerebral blood perfusion with both tracers. Technetium-99m-ECD had rapid washout from the inflamed tissue, while 99mTc-HMPAO had avid uptake. Hypofixation of 99mTc-ECD leads to failure to detect the characteristic finding of temporal lobe hyperemia in acute HSE.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Encefalite Viral / Compostos Radiofarmacêuticos / Cisteína / Herpes Simples Limite: Aged / Female / Humans Idioma: En Revista: J Nucl Med Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Áustria
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Encefalite Viral / Compostos Radiofarmacêuticos / Cisteína / Herpes Simples Limite: Aged / Female / Humans Idioma: En Revista: J Nucl Med Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Áustria