Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Immunohematology ; 39(1): 32-34, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37017601

RESUMEN

Dia is one of the most clinically significant low-prevalence antigens in the Diego blood group system, since antibodies to Dia have, albeit rarely, been implicated in hemolytic transfusion reactions and hemolytic disease of the fetus and newborn (HDFN). Given the geographical association, most anti-Dia HDFN cases have been reported in Japan, China, and Poland. We describe a case of HDFN in a neonate born to a 36-year-old G4P2012 woman of self-identified Hispanic ethnicity and of South American descent with multiple negative antibody detection tests in a U.S. hospital. Upon delivery, a cord blood direct antiglobulin test was positive (3+ reactivity), and neonatal bilirubin levels were moderately elevated, but phototherapy and transfusion were not required. This case highlights a rare, unexpected cause of HDFN in the United States secondary to anti-Dia, given the near-universal absence of this antigen and antibody in most U.S. patient populations. The case also demonstrates the need for awareness of antibodies to antigens that are considered "low-prevalence" in most populations but that might be encountered more frequently in specific racial or ethnic groups and may require more extensive testing.


Asunto(s)
Eritroblastosis Fetal , Femenino , Recién Nacido , Humanos , Adulto , Eritroblastosis Fetal/diagnóstico , Transfusión Sanguínea , Prueba de Coombs , Hemólisis , Feto , Hospitales
2.
Anaesthesist ; 64(7): 506-12, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26126940

RESUMEN

BACKGROUND: Deep neuromuscular blockade (NMB) may not always be maintained to the end of surgery and the depth of block may be allowed to gradually diminish over time, particularly if reversal of NMB is not routinely performed. AIM: The current study aimed to assess recovery from deep rocuronium-induced NMB with sugammadex compared with placebo, provide data regarding the extent of residual blockade after deep rocuronium-induced NMB (placebo group), and to determine whether complete and reliable recovery could be provided by sugammadex (sugammadex group). MATERIALS AND METHODS: This was a randomized, placebo-controlled, safety-assessor-blinded study in adult patients of American Society of Anesthesiologists Class I to III. Patients with clinically relevant kidney or liver insufficiency were excluded. Anesthesia was administered as routinely practiced at each study site. Rocuronium 0.6 mg/kg was administered for intubation, with maintenance doses of 0.1-0.2 mg/kg as needed. After the last rocuronium dose, at deep NMB (target depth 1-2 post-tetanic counts), patients received a single dose of sugammadex 4.0 mg/kg or placebo as randomized. The primary endpoint was time from sugammadex or placebo administration to recovery of the train-of-four (TOF) ratio to 0.9. Safety was assessed through monitoring of adverse events, vital signs and physical examination. Patients were also assessed for evidence of residual or recurrence of NMB. With this design, the study will provide data regarding the extent of residual blockade under these conditions (placebo group), and determine whether complete and reliable recovery could be provided by sugammadex (sugammadex group). RESULTS: Recovery to a TOF ratio of ≥ 0.9 with sugammadex was significantly faster (~ 40 times) than spontaneous recovery: geometric mean (95 % confidence interval) times were 2.2 (1.9-2.5) and 89.8 (80.1-100.7) min, respectively (p < 0.0001, N = 134); maximum spontaneous recovery was 289.8 min. Safety was comparable between groups, with no recurrence of blockade. CONCLUSIONS: This study confirms a prolonged residual blockade in patients who did not receive sugammadex, with median time to recovery > 1.5 h in the placebo group and one patient taking 4.8 h to achieve a safe level of neuromuscular function recovery following deep NMB. In contrast, sugammadex provided complete and reliable recovery of neuromuscular function (median time to recovery of 2.0 min). Thus, deep NMB with rocuronium until the end of the operation may be possible in combination with sugammadex reversal.


Asunto(s)
Androstanoles , Bloqueo Neuromuscular/métodos , Fármacos Neuromusculares no Despolarizantes , gamma-Ciclodextrinas , Adulto , Anciano , Androstanoles/efectos adversos , Periodo de Recuperación de la Anestesia , Relación Dosis-Respuesta a Droga , Determinación de Punto Final , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fármacos Neuromusculares no Despolarizantes/efectos adversos , Rocuronio , Sugammadex , Adulto Joven
3.
J Pathol Inform ; 7: 56, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28197359

RESUMEN

CONTEXT: The quality of images produced by whole slide imaging (WSI) scanners has a direct influence on the readers' performance and reliability of the clinical diagnosis. Therefore, WSI scanners should produce not only high quality but also consistent quality images. AIM: We aim to evaluate reproducibility of WSI scanners based on the quality of images produced over time and among multiple scanners. The evaluation is independent of content or context of test specimen. METHODS: The ultimate judge of image quality is a pathologist, however, subjective evaluations are heavily influenced by the complexity of a case and subtle variations introduced by a scanner can be easily overlooked. Therefore, we employed a quantitative image quality assessment method based on clinically relevant parameters, such as sharpness and brightness, acquired in a survey of pathologists. The acceptable level of quality per parameter was determined in a subjective study. The evaluation of scanner reproducibility was conducted with Philips Ultra-Fast Scanners. A set of 36 HercepTest™ slides were used in three sub-studies addressing variations due to systems and time, producing 8640 test images for evaluation. RESULTS: The results showed that the majority of images in all the sub-studies are within the acceptable quality level; however, some scanners produce higher quality images more often than others. The results are independent of case types, and they match our perception of quality. CONCLUSION: The quantitative image quality assessment method was successfully applied in the HercepTest™ slides to evaluate WSI scanner reproducibility. The proposed method is generic and applicable to any other types of slide stains and scanners.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA