1.
Artif Organs ; 46(5): 804-812, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34153137

RESUMEN

Although total hip arthroplasty (THA) has shown successful results, instability remains a major complication. In recent years, dual mobility cups (DMC) have gained interest among clinicians thanks to its low rate of dislocation and good clinical results. The main aim of this work was to describe the accuracy of data on DMC from national and regional joint registries (JRs) and the available worldwide literature. We identified topics on DMC among JRs to propose a new harmonized and standardized section for DMC with the aim to understand its surveillance over the time. We extracted survival and implant data for a separate analysis. After performing a critical exclusion process, nine JRs were considered eligible and included for final synthesis; these were the results from the available worldwide data from JRs. In our study, eight analyzed JRs reported a slight increase in DMC use in the last decade. In all the JRs evaluated and the available articles, dislocation remains one of the main reasons for revision and re-revision in hip arthroplasties. DMC is considered to be a valid construct increasingly used worldwide in primary and revision THA with the primary aim of reducing dislocation rates. Annual reports from JRs collect heterogeneous and low-quality information about outcomes and surveillance of DMC, creating a burden for clinicians to extract comparable data from different JRs. Longer follow-up and a systematic registering of DMCs with international registry harmonization are needed to monitor DMC outcomes.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Luxaciones Articulares , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Luxación de la Cadera/complicaciones , Luxación de la Cadera/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Luxaciones Articulares/cirugía , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Estudios Retrospectivos
2.
Int Orthop ; 43(6): 1365-1370, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30426179

RESUMEN

PURPOSE: The effect of being obese on the long-term survival of total joint arthroplasty is persistently discussed. Considering only studies with large cohort of patients and meta-analysis, a high body mass index has been correlated with a higher incidence of complication but not univocally with a lower survival rate. In this study, we analyzed, retrospectively, the data of patients that received unicompartmental knee prostheses in order to examine if obesity has an effect on clinical outcomes. METHODS: A retrospective multi-centre study was carried out on 4964 unicompartmental knee replacements between July 2000 and December 2016, the patients involved were 3976, with 988 bilateral cases. The patients were categorized into three groups: non-obese with a body mass index (BMI) < 30 kg/m2, obese with BMI ranged between 30 and 39 kg/m2, and morbidly obese (BMI ≥ 40 kg/m2). The outcome was measured using the Cox proportional hazards model with end point UKA revision for any reasons. Results were stratified for sex, age, weight, and bi-laterality. RESULTS: The morbidly obese group was significantly younger and required a significantly longer operating time. No statistical significant differences were observed considering the BMI groups in terms of type of insert, type of tibial component, prosthetic condyle, and prosthesis fixation (p > 0.05; chi-square test). CONCLUSIONS: Obese and morbidly obese patients have as much to gain from total knee replacement as non-obese patients.


Asunto(s)
Prótesis de la Rodilla , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla , Índice de Masa Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad Mórbida , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Tibia/cirugía , Adulto Joven
3.
Acta Orthop ; 90(5): 417-420, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31210073

RESUMEN

Background and purpose - Little is known about the role of retained trunnions in revision hip arthroplasties, i.e., when only the femoral head is substituted. Wear (fretting corrosion) and ceramic head fractures are 2 poorly understood concerns related to use, and the role of adapter sleeves has not been defined. In this registry study we assessed the influence of sleeve interposition on re-revision rates in revision hip arthroplasties with retained stems. Confounding factors (demographics, implant-related features) and failures were also analyzed. Patients and methods - We conducted a registry study on 1,127 revised implants (retained trunnion and head exchange). In 26% of implants an adapter sleeve was interposed; in 74% no adapter sleeve was implanted. Demographic and implant-related features were investigated including a descriptive analysis of failures. Results - The mean follow-up of revised implants with and without the use of an adapter sleeve was 3.3 and 5.1 years, respectively. The implant survival without an adapter sleeve was significantly higher, 98.4% (95% CI 96.9-99.8) vs. 95.2% (CI 93.2-96.6) with an adapter sleeve at 5 years. No re-revisions due to adverse local tissue reactions or ceramic head fractures were reported. In order to overcome the different distribution of head materials and head sizes in the two cohorts, only Delta balls were investigated. Interpretation - Adapter sleeve interposition had a minor influence on the revision rates. No adverse local tissue reactions or head fractures occurred.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Falla de Prótesis/etiología , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Reoperación/estadística & datos numéricos
4.
Med Princ Pract ; 26(4): 387-389, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28445875

RESUMEN

OBJECTIVE: The main goal of this case was to report the treatment of bicondylar fractures of the tibial plateau and the restoration of the metaphyseo-diaphyseal dissociation. CLINICAL PRESENTATION AND INTERVENTION: A 54-year-old male who was cycling had a road accident that caused a closed fracture of the right tibial plateau and proximal fibula diagnosed by X-rays. The patient underwent surgery and was immobilized with a long-leg splint for 4 weeks. After immobilization, aggressive rehabilitation was done. Progressive quadriceps strengthening, movements to improve symmetrical weight bearing, and functional activities were performed. The patient improved muscle strength and obtained high scores for gait and balance in a relatively short time. CONCLUSION: In this report, a bicondylar tibial fracture treated with a two-incision approach and a double-plate osteosynthesis provided strong fracture stabilization and thereby allowed an early mobilization with aggressive rehabilitation.


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas de la Tibia/cirugía , Accidentes de Tránsito , Placas Óseas , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/métodos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/rehabilitación , Resultado del Tratamiento
5.
Artif Organs ; 40(2): 195-201, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26147451

RESUMEN

The problems associated with prosthetic failure and revision surgery still constitute the main clinical problem of prosthetic surgery. The objective of wear evaluation is to determine the wear rate and its dependence on the test conditions. To obtain realistic results, a wear test can be performed to reproduce in vivo working conditions and compare the wear characteristics of various total knee prostheses designs. At the state of the art, two simulation concepts are available and defined in ISO 14243 standards series. In both these guidelines, level walking is the sole activity of daily living that is represented for testing. With so many variables and so many sources of error and the sensitivity of the output to these errors, can the motion determined in the simulator be representative of the in vivo motion? This article goes beyond the current status of these knee simulations comparing literature results.


Asunto(s)
Análisis de Falla de Equipo , Prótesis de la Rodilla , Fenómenos Biomecánicos , Simulación por Computador , Humanos , Ensayo de Materiales , Modelos Biológicos , Diseño de Prótesis , Caminata
6.
Int Orthop ; 40(11): 2261-2269, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26923378

RESUMEN

INTRODUCTION: Since 1979 the number of patients treated with femoral stems has continued to grow, as well as the number of stems with features similar to the Zweymüller prosthesis produced by different companies. Identification can be problematic in case requiring revision. In the present paper, we present an overview of morphometric differences between the different stem designs, which can be useful for radiologic identification in revision cases. METHODS: By doing some research on the Internet of specialized sites and worldwide literature, we searched for all femoral stems agreeing with Zweymüller principles (cementless, straight, tapered, rectangular cross-sectioned femoral stems). RESULTS: We found 26 different stems from different companies producing or having produced in the past the Zweymüller-type femoral stems for hip prosthesis. DISCUSSION: Accurate preoperative identification of the Zweymüller femoral stem type may be of critical importance to eventual outcomes following revision surgery. Each manufacturer has different instruments specific to the removal of their primary implants, and ensuring they are available can simplify the revision procedure significantly. Exact pre-operative planning is also necessary for selecting the correct ball head in cases where a stem is well-fixed and can be left in situ. The commonly used notation "Eurocone 12/14" provides no information about the actual taper angle. Whenever the stem is left in situ, the exact specifications of the taper must therefore be obtained from the manufacturer in order to use a metal sleeve that precisely fits it and the ball head. Failure to do so may result in severe complications, such as metallosis. In cases where it is not possible to identify the taper angle, the surgeon may even consider removal of the stem, though this significantly increases the surgical procedure's invasiveness. Only a single, uniform standard taper, such as that offered until 1994 by CeramTec, can solve these issues in the future. CONCLUSION: The survival rate of the Zweymüller stems after ten years was 96 % and the complication rate was very low. Pre-operative identification of the femoral implant is of considerable importance for planning and correctly implementing revision procedures.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Diseño de Prótesis , Artroplastia de Reemplazo de Cadera/métodos , Fémur/diagnóstico por imagen , Humanos , Falla de Prótesis , Reoperación
7.
Int Orthop ; 39(7): 1433-40, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25500956

RESUMEN

PURPOSE: Wear and survival of total joint replacements do not depend on the duration of the implant in situ, but rather on the amount of its use, i.e. the patient's activity level. With this in mind, the present study was driven by two questions: (1) How does total knee replacement (TKR) respond to the simulation of daily highly demanding activities? (2) Are certain activities to be advised against or, on the contrary, useful to implanted patients, in order to reduce wear of TKR and its related problems? METHODS: One set of the same total knee prosthesis (TKP), equal in design and size, was tested on a three-plus-one knee joint simulator for two million cycles using a highly demanding daily load waveform, replicating a stair-climbing movement. The results were compared with a set of TKP previously tested with the ISO level walking task. A digital microscope was used to characterise the superficial structure of all the TKPs. Gravimetric and micro-Raman spectroscopic analyses were carried out on the polyethylene inserts. Visual comparison with in vivo explants was carried out. RESULTS: The average volumetric mass loss after two million cycles was 44 ± 6 mm(3). Microscope examinations showed some deep scratches along the flexion/extension movements for all the components. Also, the metallic backside surface showed intense non-linear scratches and the polyethylene counterface was characterised by some craters. A decrease in crystallinity, induced by mechanical stress was observed on all polyethylene components and was quantitatively confirmed by the orthorhombic fraction αo value. CONCLUSIONS: The results of this study demonstrated that the forces and motion sustained by the knee are highly activity-dependent. Moreover, this test confirmed that under more severe conditions, the material properties change according to a different wear mechanism and a decrease in crystallinity occurs. Loading characteristics for specific activities should be considered for the design of functional and robust TKRs.


Asunto(s)
Articulación de la Rodilla/fisiología , Prótesis de la Rodilla , Movimiento , Diseño de Prótesis , Adulto , Artroplastia de Reemplazo de Rodilla/rehabilitación , Análisis de Falla de Equipo , Femenino , Humanos , Articulación de la Rodilla/cirugía , Ensayo de Materiales , Persona de Mediana Edad , Polietileno/química , Espectrometría Raman , Estrés Mecánico
8.
Int Orthop ; 38(6): 1183-90, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24570153

RESUMEN

PURPOSE: The research questions of the present study were: (1) Is total knee prosthesis wear behaviour influenced by implant size, body weight and their combined effect? (2) Are these findings significant and helpful from a clinical point of view? METHODS: Two very different sizes of the same total knee prosthesis (TKP), previously tested with ISO 14243 parameters, were tested on a knee simulator for a further two million cycles using a modified ISO 14243 load waveform. Roughness examination was performed on the metallic components. Gravimetric and micro-Raman spectroscopic analyses were carried out on the polyethylene inserts. RESULTS: The average volumetric mass loss was 69 ± 3 mm(3) and 88 ± 4 mm(3) for smaller and bigger size, respectively. Bigger TKPs are little influenced by an increased load, while the wear trend of the smaller TKP showed a redoubled slope, and more significant morphology changes were observed. However, the two sizes seem to behave similarly when subjected to a load increase of 15 %; the slope of the volumetric mass loss trend was comparable for the two sets of inserts, which did not appear significantly different also at the molecular level. Roughness average parameters of the lateral femoral condyle support this evidence. CONCLUSIONS: It can be asserted that the body weight and implant size are relevant to the understanding of TKP wear behaviour. A post-implantation body weight increase in a patient with smaller knee dimensions could results in more critical effects on prosthesis long-term performance.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Análisis de Falla de Equipo , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Falla de Prótesis , Peso Corporal , Humanos , Diseño de Prótesis
9.
Proc Inst Mech Eng H ; 227(1): 27-36, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23516953

RESUMEN

Unicondylar knee replacement systems have been shown to perform comparably to total knee replacements, while being much less surgically invasive. Proper ligament balancing, as well as knee laxity, has been shown to play an important role in optimizing kinematic behavior of these implant systems and improving long-term survival of the implant. This study investigates the effect of different simulated ligament laxity conditions of the anterior cruciate ligament and the posterior cruciate ligament on the resulting anteroposterior and mediolateral contact kinematics for medial and lateral pairs of UKR implants with flat and symmetric ultrahigh-molecular-weight polyethylene inserts during force-controlled ISO-14243-1 knee testing simulation. A novel method of capturing the tibiofemoral lowest point contact path was used to calculate the shear plane lowest point contact path kinematics in both the anteroposterior and the mediolateral directions. The results illustrated that multiple clinically relevant soft tissue configurations produce statistically different measured knee kinematics in unicondylar knee replacement systems than is seen in accepted "standard" knee simulator protocols with 95% confidence interval. The observed kinematic differences in anteroposterior and mediolateral movement from what was observed using standard wear testing protocols could aid in the development of unicondylar knee replacement design enhancements that are resistant to varying soft tissue deficiencies.


Asunto(s)
Ligamento Cruzado Anterior/fisiopatología , Inestabilidad de la Articulación/fisiopatología , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Ligamento Cruzado Posterior/fisiopatología , Ligamento Cruzado Anterior/cirugía , Simulación por Computador , Humanos , Modelos Biológicos , Ligamento Cruzado Posterior/cirugía , Rango del Movimiento Articular , Resultado del Tratamiento
10.
J Biomed Mater Res B Appl Biomater ; 110(10): 2299-2309, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35524679

RESUMEN

The aim of the present study was to evaluate how much reduction in acetabular liner thickness could be tribologically acceptable in metal-on-vitamin-E diffused highly crosslinked ultra-high molecular weight polyethylene (Vit-E XLPE) bearings for total hip arthroplasty. We tested thick- (10.3 mm), moderate- (6.3 mm), and thin- (4.3 mm) Vit-E XLPE liners coupled with 28-mm cobalt-chromium femoral heads on a hip simulator to 5 million cycles, and peak contact stress was predicted based on mathematical modeling. Wear damage was also evaluated in terms of surface topology and morphology. Wear simulation demonstrated that the 2-4 mm thickness reduction (6.3 → 4.3 mm and 10.3 → 6.3 mm) did not significantly affect the wear rate for Vit-E XLPE liner, whereas 6-mm reduction (10.3 → 4.3 mm) significantly increased liner wear (by 309%) and head roughness (by 415%). This effect was attributed to a contact stress increase (by 24-41%). However, the wear rates for all thicknesses tested were much lower than those previously reported for thicker non-crosslinked materials. The original crystalline morphology was maintained in all liners after wear. Our results suggest that the 2-4 mm thickness reduction may be tribologically acceptable in Vit-E XLPE liners. However, more severe and longer term simulations are necessary to determine a minimum acceptable thickness.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo , Humanos , Metales , Polietileno/química , Diseño de Prótesis , Falla de Prótesis , Vitamina E/química
11.
J Mech Behav Biomed Mater ; 116: 104328, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33508557

RESUMEN

The infection rate of total knee arthroplasty is still high, in spite of the high success of this surgical procedure. The use of an antibiotic-loaded temporary spacer made of poly(methyl methacrylate) (PMMA) has been proposed to treat infected knee arthroplasties. This study was aimed at comparatively investigating, on a molecular scale, two types of spacers from the same manufacturer (Spacer K and Vancogenx-space knee, Tecres, Italy), which differ for the added antibiotic (gentamicin sulphate in Spacer K and gentamicin sulphate + vancomycin hydrochloride in Vancogenx). Raman spectroscopy was used to gain more insights into the possible effects of the antibiotic on the spacer composition and polymer structure both in the new components and after in vivo use. Vancogenx was found to contain a lower residual MMA content than Spacer K (about 0.15% versus 0.4%). The former contained a higher amount of isotactic stereosequences than the latter, while the syndiotactic content (the prevailing component) was not significantly different in the two prostheses. The presence of vancomycin hydrochloride influenced not only the degree of polymerization and PMMA tacticity and crystallinity, but in turn also the wear behavior. Actually, Spacer K retrievals were found more affected by in vivo implantation than Vancogenx-space knee ones, revealing slight variations in polymer tacticity and crystallinity and relative radiopacifier content, besides release of MMA and additives of polymerization. However, these changes did not appear worrisome, due to the temporary nature of the prosthesis. In view of these results, the addition of vancomycin hydrochloride could offer an advantage, in spite of the higher costs requested and the potential risks of its unselective use.


Asunto(s)
Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Antibacterianos , Cementos para Huesos , Humanos , Estructura Molecular , Polimetil Metacrilato , Infecciones Relacionadas con Prótesis/tratamiento farmacológico
12.
Materials (Basel) ; 14(2)2021 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-33467142

RESUMEN

This paper aims to characterize the wear behavior of hydrogel constructs designed for human articular cartilage replacement. To this purpose, poly (ethylene glycol) diacrylate (PEGDA) 10% w/v and gellan gum (GG) 1.5% w/v were used to reproduce the superior (SUP) cartilage layer and PEGDA 15% w/v and GG 1.5% w/v were used to reproduce the deep (DEEP) cartilage layer, with or without graphene oxide (GO). These materials (SUP and DEEP) were analyzed alone and in combination to mimic the zonal architecture of human articular cartilage. The developed constructs were tested using a four-station displacement control knee joint simulator under bovine calf serum. Roughness and micro-computer tomography (µ-CT) measurements evidenced that the hydrogels with 10% w/v of PEGDA showed a worse behavior both in terms of roughness increase and loss of uniformly distributed density than 15% w/v of PEGDA. The simultaneous presence of GO and 15% w/v PEGDA contributed to keeping the hydrogel construct's characteristics. The Raman spectra of the control samples showed the presence of unreacted C=C bonds in all the hydrogels. The degree of crosslinking increased along the series SUP < DEEP + SUP < DEEP without GO. The Raman spectra of the tested hydrogels showed the loss of diacrylate groups in all the samples, due to the washout of unreacted PEGDA in bovine calf serum aqueous environment. The loss decreased along the series SUP > DEEP + SUP > DEEP, further confirming that the degree of photo-crosslinking of the starting materials plays a key role in determining their wear behavior. µ-CT and Raman spectroscopy proved to be suitable techniques to characterize the structure and composition of hydrogels.

13.
Materials (Basel) ; 14(9)2021 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-33921972

RESUMEN

Success of total knee replacement (TKR) depends on the prosthetic design and materials. The use of metal components is well established with the disadvantage of allergic reactions. Ceramics have been recently proposed because of high wear resistance, excellent biocompatibility, wettability, and suitable mechanical properties. This study was aimed at investigating in vitro wear resistance of Zirconia Toughened Alumina (ZTA)/Ultra-high-molecular-weight polyethylene (UHMWPE) of TKR femoral components. An in vitro protocol was designed with the application of relevant load profile, 6-degrees-of-freedom knee simulator, and 8 × 105 cycles on the ZTA/UHMWPE configuration under bovine calf serum. Before and after wear test, the femoral components were investigated by using the Scanning Electron Microscope (SEM) and the X-Ray Diffraction (XRD) analyses, and stylus surface roughness measurements. The proposed pre-clinical test yielded repeatable results. In particular, gravimetric results showed that, after 8 × 105 cycles, the mean weight loss of the polyethylene mobile components is 5.3 ± 1.1 mg. The surface roughness measurements (Ramax) performed after the wear test showed no significant variation on the UHMWPE menisci. A slight increase of roughness has been found on the ZTA (0.02 µm before wear test, 0.28 µm after the test). SEM observations did not show significant modification of the surface morphology. Tetragonal to monoclinic phase ratio was measured by XRD before and after wear test to evaluate stability of tetragonal ZrO2 phase. Minimal conversion of tetragonal to monoclinic phase was found from 5.4 to 8%. Although this study is a preliminary evaluation limited to in vitro tests, it provides novel pre-clinical indications about the potential of ceramic TKR femoral components.

14.
Adv Healthc Mater ; 10(7): e2001434, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33586352

RESUMEN

Articular cartilage (AC) is a specialized connective tissue able to provide a low-friction gliding surface supporting shock-absorption, reducing stresses, and guaranteeing wear-resistance thanks to its structure and mechanical and lubrication properties. Being an avascular tissue, AC has a limited ability to heal defects. Nowadays, conventional strategies show several limitations, which results in ineffective restoration of chondral defects. Several tissue engineering approaches have been proposed to restore the AC's native properties without reproducing its mechanical and lubrication properties yet. This work reports the fabrication of a bilayered structure made of gellan gum (GG) and poly (ethylene glycol) diacrylate (PEGDA), able to mimic the mechanical and lubrication features of both AC superficial and deep zones. Through appropriate combinations of GG and PEGDA, cartilage Young's modulus is effectively mimicked for both zones. Graphene oxide is used as a dopant agent for the superficial hydrogel layer, demonstrating a lower friction than the nondoped counterpart. The bilayered hydrogel's antiwear properties are confirmed by using a knee simulator, following ISO 14243. Finally, in vitro tests with human chondrocytes confirm the absence of cytotoxicity effects. The results shown in this paper open the way to a multilayered synthetic injectable or surgically implantable filler for restoring AC defects.


Asunto(s)
Cartílago Articular , Grafito , Humanos , Hidrogeles , Lubrificación , Polisacáridos Bacterianos , Ingeniería de Tejidos
15.
Artif Organs ; 34(4): 319-23, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20420614

RESUMEN

Ceramic-on-ceramic and metal-on-metal bearing surfaces are often employed for total hip replacement because of their resistance to wear. However, they have some limits: brittleness is a major concern for ceramic, and ion release is a drawback for metal. To reduce the effect of these limitations, a hybrid coupling of ceramic-on-metal has been proposed. The theoretical advantage of this new coupling might lead orthopedic surgeons to use it indiscriminately. We asked whether the wear rate of this innovative solution was comparable with that of ceramic-on-ceramic, which is considered to be the gold standard for wear resistance. In a hip simulator study, we tested the wear pattern of a hybrid ceramic-on-metal coupling supplied by the same distributor; in particular, three different configurations were tested for 5 million cycles: 36-mm ceramic-on-ceramic, 32-mm and 36-mm ceramic-on-metal. These combinations were gravimetrically and geometrically evaluated. After 5 million cycles, the volumetric loss for the metal acetabular cups (Phi 36-mm) was 20-fold greater than that of the ceramic cups of the same size (Phi 36-mm); a volumetric loss of 4.35 mm(3) and 0.26 mm(3) was observed, respectively, for ceramic-on-metal and ceramic-on-ceramic combinations. Significant statistical differences were observed between all 36-mm different combinations (P < 0.0001). The increased diameter of the 36-mm ceramic-on-metal configuration resulted in a lower volumetric loss compared with that of the 32-mm ceramic-on-metal configuration. Our findings showed an increase in wear for the proposed hybrid specimens with respect to that of the ceramic-on-ceramic ones. This confirms that even in the case of ceramic-on-metal bearings, mixing and matching could not prove effective wear behavior, not even comparable with that of the ceramic-on-ceramic gold standard.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cerámica , Ensayo de Materiales/instrumentación , Metales , Materiales Biocompatibles , Prótesis de Cadera , Diseño de Prótesis , Propiedades de Superficie
16.
Artif Organs ; 34(5): E177-83, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20633148

RESUMEN

The success of a total knee replacement (TKR) strongly depends on the prosthetic design; this includes on one hand the best choice of the bearing materials to minimize wear, on the other hand a good orientation of the prosthetic components with respect to the loading directions. The aim of this study was to investigate the feasibility of a new experimental setup combining two fundamental aspects for the long-term success of knee implants: wear and micromotions. A novel procedure was used to simulate working conditions as close as possible to in vivo ones and to measure implant-bone micromotion, by means of fixing the femoral component of the prosthesis to the distal part of a synthetic femur to be tested through a knee simulator. Gravimetric wear of the tibial specimens was assessed at regular intervals. Implant-bone inducible micromotions and permanent migrations were measured at three locations throughout the test. Wear patterns on tibial specimens were characterized through a standardized protocol based on digital image analysis; fatigue damage in the cement was quantified. Some initial conditioning was noticed both in the wear process and microcracking distribution within the cement mantle. Similarity in wear tracks observed on tibial inserts and other retrieval studies, coupled with clinically consistent migration patterns for TKR, supports the efficacy of the new in vitro method presented.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Diseño de Prótesis/métodos , Artroplastia de Reemplazo de Rodilla/métodos , Simulación por Computador , Fémur/cirugía , Articulación de la Rodilla/cirugía , Modelos Biológicos , Polietilenos , Falla de Prótesis
17.
Int J Artif Organs ; 43(3): 203-207, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31564193

RESUMEN

Unicompartmental knee arthroplasty remains a challenge for orthopaedic surgeons because of its higher revision rate compare with the total knee arthroplasty. The hypothesis of this work is that the progression of osteoarthritis in unicompartmental knee prostheses is the natural history of the degenerative disease and a reason for reoperation. Most international joint registries consider this fact as a failure of the implant and a cause of revision. Annual joint registries were searched for progression of osteoarthritis in unicompartmental knee arthroplasty and reasons for their revisions. Current data from registries for unicompartmental knee indicate that the revision rate of such prostheses is overestimated. Considering osteoarthritis progression as the development of the existing disease and not as a failure of the implant, revision rate will be reduced. Registries, reports, and studies are needed to evaluate the progression of osteoarthritis as a cause of reoperation instead of a reason for revision, reducing unicompartmental revision rate and encouraging surgeons to implant more of them.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla/efectos adversos , Osteoartritis , Complicaciones Posoperatorias/diagnóstico , Reoperación/estadística & datos numéricos , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Diagnóstico Diferencial , Progresión de la Enfermedad , Análisis de Falla de Equipo/métodos , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico , Osteoartritis/fisiopatología , Osteoartritis/cirugía , Complicaciones Posoperatorias/etiología , Sistema de Registros/estadística & datos numéricos , Resultado del Tratamiento
18.
J Mech Behav Biomed Mater ; 110: 103959, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32957250

RESUMEN

PURPOSE: Although total knee arthroplasty is a well-practiced surgical procedure, material properties and surface topography can contribute to the wear mechanisms and the implant failure. It has been advised that an increased femoral component's surface roughness of total knee prostheses may be a contributing factor to accelerated wear of the polyethylene menisci and eventually prosthesis failure. The aim of this study is to investigate the wear phenomena occurring on medial and lateral compartments of retrieved total knee arthroplasty in order to correlate the surface roughness vs. BMI, age at revision, and time in situ. METHODS: Qualitative visual analyses were performed on all the retrieved knee components to assess the damage due to the wear phenomena. Quantitative analysis includes surface characterization performed using optical apparatus to describe surface roughness and morphology on the retrieved femoral, tibial and polyethylene component. The Mann-Whitney statistical test was performed to correlate the medial vs. lateral condyle surface roughness of all explants with BMI, age at revision, and time in situ. RESULTS: Visual and topographical analysis showed damage along the entire zone of the sliding contact area. A statistical difference between medial and lateral condyle roughness was found on four prosthesis. No statistical significance was found between surface roughness measurements and patient BMI, age at revision, and time in situ. On the femoral components various scratches were observed in the anterior/posterior (AP) direction of all the fixed femoral components. A statistically significant difference between medial and lateral condyle was found on two mobile knee design (p = 0.03) and on two fixed design (p = 0.01). The results were discussed in the framework of the usual TKR loading conditions during the gait, and of knowledge on the bio-tribological behavior of the prosthetic joint. CONCLUSIONS: The visual and topographical analysis showed consistent damage patterns with respect to the main movements to which the prosthetic components are subjected and no statistical significance was found between surface roughness measurements and patient BMI, age at revision, and time in situ.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Menisco , Humanos , Articulación de la Rodilla/cirugía , Polietileno , Diseño de Prótesis , Falla de Prótesis
19.
Materials (Basel) ; 13(10)2020 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-32443746

RESUMEN

It is well known that wear occurring in polyethylene menisci is a significant clinical problem. At this regard, wear tests on biomaterials medical devices are performed in order to assess their pre-clinical performance in terms of wear, durability, resistance to fatigue, etc. The objective of this study was to assess the wear of mobile total knee polyethylene inserts after an in vitro wear test. In particular, the wear behavior of mobile bearing polyethylene knee configurations was investigated using a knee joint wear simulator. After the completion of the wear test, the polyethylene mobile menisci were analyzed through a consolidated procedure by using 3D optical scanners, in order to evaluate the 3D wear distribution on the prosthesis surface, wear depths, wear rates, amount of material loss and contact areas. The results in terms of wear rates and wear volumes were compared with results of gravimetric tests, finding equivalent achievements.

20.
Materials (Basel) ; 13(9)2020 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-32349434

RESUMEN

Revision of large-diameter, monoblock acetabular components for both hip resurfacing arthroplasty and metal-on-metal (MoM) total hip arthroplasty (THA) is correlated to a high amount of complications. For this reason, performing a limited revision by conversion to a dual mobility (DM) without acetabular component exchange has been proposed in order to limit these complications. Although DM bearing offers an easy solution avoiding the intraoperative and time-associated complications, concern about polyethylene wear and stability remains due to the difference regarding the design, the coverage angle and the clearance of the two implants. In order to evaluate the performance of this new solution with the new material to prevent the possibility of failure it is essential to conduct a review of the literature A qualitative systematic review of the literature has been conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search of PubMed, EMBASE, Google Scholar, and Scopus for English and French articles between January 2000 and October 2019 was performed, with the primary objective of finding articles about dual mobility bearing coupling with large metal-on-metal cup in the case of hip revision procedure. Various combinations of the key words were used in the search strategy. Thirteen articles with DM bearing mated with MoM cup were analyzed. Of the 130 hip revisions selected, with a follow-up from 6 to 53 months, there were a total of 14 with complications (10.77%): four true dislocations (3.08%); six intra-prosthetic dislocations (IPD, 4.6%), two of which presented plastic deformation and polyethylene wear; four other complications (3.08%), included a cup osteolysis, a clicking noise, a superficial infection and a periprosthetic fracture. All the mentioned true dislocations occurred during the first month while IPDs appeared during the first two years from the index revision. In conclusion, according to the literature analyzed, we can stress that the concerns and doubts about mating a DM bearing with large MoM cup cannot be dissolved. It has been pointed out that a DM bearing is not designed for a MoM cup; it is not mechanically tested on MoM cups, which presents different clearance and coverage angles. Predictable complications may occur, such as IPD, polyethylene wear and true dislocation. These complications have been reported at an even higher rate than they were in the eighties, when the first generation of DM implants were of a lower quality of polyethylene and the characteristic of the design was less optimal than modern ones.