RESUMEN
OBJECTIVES: This study aimed to explore regional mitral annular strain using a novel computational method. METHODS: Eight pigs underwent implantation with piezoelectric transducers around the mitral annulus. Interventions of pre- and afterload were performed by inferior vena cava constriction and endovascular balloon occlusion of the descending aorta. The mitral annulus was reconstructed in a mathematical model and divided into 6 segments. Global and segmental annular strain were calculated from a discrete mathematical representation. RESULTS: Global annular strain gradually decreased after isovolumetric contraction until late systole. Mitral annular end-systolic strain demonstrated shortening in all segments except the anterior segment, which showed the least deformation. The P2 annular segment demonstrated the most end-systolic shortening (-7.6 ± 1.1% at baseline, P < 0.001 compared to anterior segment). Systolic global annular strain showed no significant change in response to load interventions but correlated positively with left ventricular contractility at baseline and after preload reduction. CONCLUSIONS: Mitral annular systolic strain demonstrates cyclical variations with considerable regional heterogeneity, with the most pronounced deformation in posterior annular segments. Measurements appear independent of changes to pre- and afterload.
RESUMEN
The purpose of this study was to investigate the effects of loading conditions and left ventricular (LV) contractility on mitral annular dynamics. In 10 anesthetized pigs, eight piezoelectric transducers were implanted equidistantly around the mitral annulus. High-fidelity catheters measured left ventricular pressures and the slope of the end-systolic pressure-volume relationship (Ees ) determined LV contractility. Adjustments of pre- and afterload were done by constriction of the inferior caval vein and occlusion of the descending aorta. Mitral annulus area indexed to body surface area (MAAi ), annular circularity index (ACI), and non-planarity angle (NPA) were calculated by computational analysis. MAAi was more dynamic in response to loading interventions than ACI and NPA. However, MAAi maximal cyclical reduction (-Δr) and average deformational velocity (- v ¯ $$ \overline{v} $$ ) did not change accordingly (p = 0.31 and p = 0.22). Reduced Ees was associated to attenuation in MAAi -Δr and MAAi - v ¯ $$ \overline{v} $$ (r2 = 0.744; p = 0.001 and r2 = 0.467; p = 0.029). In conclusion, increased cardiac load and reduced LV contractility may cause deterioration of mitral annular dynamics, likely impairing coaptation and increasing susceptibility to valvular incompetence.