Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 102(4): 585-593, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37560823

RESUMEN

BACKGROUND: Donor vessel injury is a potentially life-threatening complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). AIMS: Our goal was to examine the incidence, mechanisms, treatment, and outcomes of patients with donor vessel injury in a large multicenter CTO PCI registry. METHODS: We analyzed the baseline clinical and angiographic characteristics, and procedural outcomes of 12,349 CTO PCIs performed between 2012 and 2022 at 44 centers. RESULTS: The incidence of donor vessel injury was 0.35% (n = 43). The baseline clinical characteristics of patients with and without donor vessel injury were similar. Cases complicated by donor vessel injury were more complex with higher Japanese CTO score (2.9 ± 1.1 vs. 2.4 ± 1.3; p = 0.004) and lower procedural success rate (69.8% vs. 85.2%; p = 0.004). The retrograde approach was used more commonly in donor vessel injury cases (68.9% vs. 30.9%; p < 0.001). Most (53.5%) donor vessel injuries were guide catheter-induced, whereas 20.9% were due to donor vessel thrombosis. Of the 43 patients with donor vessel injury, 36 (83.7%) were treated with stenting and seven (16.3%) received a left ventricular assist device. The incidence of major adverse cardiovascular events (MACEs) was significantly higher in cases with donor vessel injury (23.3% vs. 2.0%; p < 0.001). Of the 43 patients with donor vessel injury, five patients (11.6%) experienced acute myocardial infarction and four patients (9.3%) died. CONCLUSIONS: Donor vessel injury, occurred in 0.35% of CTO PCIs performed by experienced operators, was mainly due to guide catheter-induced dissection or thrombosis and was associated with lower procedural success and higher MACE.

2.
Catheter Cardiovasc Interv ; 99(3): 906-914, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34569695

RESUMEN

BACKGROUND: There is a paucity of real-world data regarding the temporal trends and outcomes of trans-septal transcatheter mitral valve replacement (TS-TMVR) in the United States (US). METHODS: We queried the Nationwide Readmissions Database (October 2015 to December 2018) for patients undergoing TS-TMVR procedures. We reported the temporal trends in the utilization, in-hospital outcomes and 30-day readmissions after TS-TMVR. The main study outcome was in-hospital mortality. RESULTS: There was an increase in the number of TS-TMVR procedures over time (48 in 2015 vs. 978 in 2018, Ptrend < 0.001), with a notable increase in the proportion of women (Ptrend  = 0.04) and the prevalence of diabetes (Ptrend  = 0.03). There was an increase in the number of centers performing TS-TMVR (21 in 2015 vs. 164 in 2018, Ptrend < 0.001). The overall in-hospital mortality was 7.2% with no change over time (6.3% in 2015 vs. to 5.2% in 2018, Ptrend  = 0.67). There was no change in the frequency of in-hospital complications after TS-TMVR; however, the median length of stay has decreased over time. The overall 30-day readmission rate was 17.8%, with no change during the study years. The most frequent cause for 30-day readmission after TS-TMVR was acute heart failure followed by bleeding and infection-related complications. Prior coagulopathy and small-sized hospitals were independently associated with higher in-hospital mortality and 30-day readmissions. CONCLUSION: This nationwide observational analysis of real-world data showed an increase in the number of TS-TMVR procedures over time, which is now performed at a greater number of centers. There was no change in the rate of in-hospital mortality, complications or 30-day readmissions; but a significant reduction in the length of hospital stay over time was noted. As the number of TS-TMVR continue to expand, these data provide a perspective on the early experience with this procedure.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Readmisión del Paciente , Resultado del Tratamiento , Estados Unidos/epidemiología
3.
Catheter Cardiovasc Interv ; 97(4): 691-698, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33400380

RESUMEN

BACKGROUND: There is a paucity of data regarding the outcomes of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) among solid-organ transplant recipients. METHODS: Temporal trends in hospitalizations for aortic valve replacement among solid-organ transplant recipients were determined using the National Inpatient Sample database years 2012-2017. Propensity matching was conducted to compare admissions who underwent TAVR versus SAVR. The primary outcome was in-hospital mortality. RESULTS: The analysis included 1,730 hospitalizations for isolated AVR; 920 (53.2%) underwent TAVR and 810 (46.7%) underwent SAVR. TAVR was increasingly utilized for solid-organ transplant recipients (Ptrend = 0.01), while there was no change in the number of SAVR procedures (Ptrend = 0.20). The predictors of undergoing TAVR for solid-organ transplant recipients included older age, diabetes, and prior coronary artery bypass surgery, while TAVR was less likely utilized in small-sized hospitals. TAVR was associated with lower in-hospital mortality after matching (0.9 vs. 4.7%, odds ratio [OR] 0.19; 95% confidence interval [CI] 0.11-0.35, p < .001) and after multivariable adjustment (OR 0.07; 95% CI 0.03-0.21, p < .001). TAVR was associated with lower rate of acute kidney injury, acute stroke, postoperative bleeding, blood transfusion, vascular complications, discharge to nursing facilities, and shorter median length of hospital stay. There was no difference between both groups in the use of mechanical circulatory support, hemodialysis, arrhythmias, or pacemaker insertion. CONCLUSION: This contemporary observational nationwide analysis showed that TAVR is increasingly performed among solid-organ transplant recipients. Compared with SAVR, TAVR was associated with lower in-hospital mortality, complications, and shorter length of stay.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Trasplante de Órganos , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Curr Cardiol Rep ; 22(7): 50, 2020 06 04.
Artículo en Inglés | MEDLINE | ID: mdl-32500412

RESUMEN

PURPOSE OF REVIEW: The goal of the paper is to highlight the importance of procedural planning and patient selection when using the MitraClip device in treating severe mitral regurgitation (MR). RECENT FINDINGS: Following the recent results of the COAPT trial and FDA approval for functional MR patients, the indications for mitral clip are continuing to expand. Because of this, mitral stenosis from mitral clip can become a problem if the appropriate patients are not selected. Proper valve imaging, utilizing 3D transesophageal echocardiography to identify the pathology, is important to prevent iatrogenic mitral stenosis. In the unfortunate event of severe mitral stenosis as a result of the MitraClip device, surgery is the only treatment.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Válvula Mitral/diagnóstico por imagen , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Insuficiencia de la Válvula Mitral/terapia , Estenosis de la Válvula Mitral/diagnóstico , Estenosis de la Válvula Mitral/terapia , Resultado del Tratamiento
5.
Struct Heart ; 8(5): 100330, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39290675

RESUMEN

Background: Percutaneous mitral balloon commissurotomy (PMBC) is the gold standard for the treatment of patients with symptomatic rheumatic mitral valve (MV) stenosis and favorable valve morphology. Intracardiac ultrasound (ICE)-guided PMBC is an attractive alternative to standard transesophageal echocardiography guidance for simplification of procedure and avoiding general anesthesia. Methods: We conducted a retrospective analysis of all ICE-guided PMBC cases at our institution between July 2020 and November 2023. Procedural success was defined as post-PMBC MV area ≥1.5 cm2; or an increase of ≥0.5 cm2 in MV area associated with echocardiographic mitral regurgitation (MR) that is ≤moderate post-PMBC. Six-month follow-up data were collected. Results: We identified 11 subjects for whom ICE-guided PMBC was attempted. The mean age of the subjects was 61.7 (±12.1) years. All, but one, were females. Out of the 11 subjects, 2 did not undergo PMBC; one had baseline severe MV regurgitation identified on ICE, and the other developed a pericardial effusion following transeptal puncture that needed an urgent pericardial window. The protocol-defined procedural success was achieved in all nine patients who underwent PMBC. Post-PMBC mean MV gradient was 4.4 (±2.0) as compared to 11.1 (±2.9) mmHg at baseline. At 6-month follow-up, 8 of the 9 patients had ≤New York Heart Association class II symptoms. Conclusions: ICE-guided PMBC appears to be feasible and safe. ICE-guided PMBC offers several advantages over transesophageal echocardiography guidance including improving patient comfort and eliminating the need for patient intubation and general anesthesia.

6.
Am J Cardiol ; 230: 50-57, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39117008

RESUMEN

Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been associated with favorable outcomes in patients with degenerated stentless bioprosthesis. However, whether the outcomes after ViV TAVR for failed stentless bioprosthesis differ between balloon-expandable valves (BEVs) and self-expanding valves (SEVs) remains unknown. Therefore, we retrospectively analyzed 59 consecutive patients who underwent ViV TAVR for failed stentless bioprsothesis with BEVs (n = 42) versus SEVs (n = 17) in a single-health care system between 2013 and 2022. Overall, the mean age was 70.8 years and 74.6% were men. The mean transcatheter valve size was 26.3 ± 2.2 mm for BEVs and 26.4 ± 4 mm for SEVs (p = 0.93). The mean Society of Thoracic Surgeons score was 6.0 ± 3.6 for BEVs and 7.5 ± 5.5 for SEVs (p = 0.22). Compared with patients who received BEVs, those who received SEVs had higher rates of device malposition (2.4% vs 23.5%, p <0.01), postdeployment balloon dilation (11.9% vs 35.5%, p = 0.04) and need for a second transcatheter device (2.4% vs 35.5%, p <0.01). However, both groups showed similar improvement in aortic valve function at 30-day and 1-year follow-up (incidence of 1-year severe patient-prosthesis mismatch in BEVs: 17.6% vs 14.3% in SEVs, p = 0.78). The 1- and 3-year mortality did not differ between BEVs and SEVs (11.9% vs 11.8% and 25% vs 30%, respectively, Log rank p = 0.9). In conclusion, performing ViV TAVR for failed stentless bioprsothesis is technically challenging, especially when using SEVs; however, satisfactory positioning is possible in most cases, with excellent hemodynamic and clinical outcomes with BEVs and SEVs.

7.
Cardiovasc Revasc Med ; 61: 8-15, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37951758

RESUMEN

INTRODUCTION AND AIM: The optimal composition and duration of antiplatelet therapy after complex percutaneous coronary intervention (PCI) remains unclear. We conducted a meta-analysis to compare 1-3 months of dual antiplatelet therapy (DAPT) followed by monotherapy vs. 12 months of DAPT. METHOD: MEDLINE/PubMed, EMBASE, and Cochrane Central Register of Controlled Trials were queried for studies comparing 1-3 months of DAPT followed by monotherapy vs. 12 months of DAPT in the outcomes of complex PCI from inception through January 2023. Outcomes of interest included major bleeding, all-cause mortality, cardiovascular mortality, myocardial infarction (MI), stent thrombosis, target vessel revascularization, and stroke. RESULTS: Compared to 12 months, 1-3 months of dual antiplatelet therapy had a weak association with less major bleeding (OR 0.67; 95 % CI, 0.44-1.00; p = 0.05; I2 = 28 %). There were no significant differences between the shorter and longer antiplatelet therapy in terms of all-cause mortality (OR 0.83; 95 % CI, 0.59-1.16; p = 0.21; I2 = 17 %), cardiovascular mortality (OR 0.87; 95 % CI, 0.53-0.42; p = 0.50; I2 = 0), MI (OR 0.97; 95 % CI, 0.69-1.35; p = 0.82; I2 = 32 %), stent thrombosis (OR 1.17, 95 % CI, 0.77-1.76; p = 0.38; I2 = 0 %), target vessel revascularization (OR 1.05, 95 % CI, 0.58-1.89; p = 0.82; I2 = 64 %), or stroke (OR 1.10, 95 % CI, 0.55-2.17; p = 0.37; I2 = 7 %);. CONCLUSION: Among patients undergoing complex PCI, DAPT for 1-3 months may be associated with less major bleeding but similar rates of cardiovascular events (death, MI, stroke, stent thrombosis, and revascularization) compared to DAPT for 12 months.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Trombosis , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Stents Liberadores de Fármacos/efectos adversos , Hemorragia/inducido químicamente , Trombosis/etiología , Accidente Cerebrovascular/etiología , Quimioterapia Combinada , Resultado del Tratamiento
8.
Am J Cardiovasc Drugs ; 24(1): 71-81, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37995040

RESUMEN

INTRODUCTION: Cangrelor is a potent intravenous non-thienopyridine P2Y12 inhibitor. We conducted a network meta-analysis to study the efficacy and safety of cangrelor as compared with the oral P2Y12 inhibition, clopidogrel, or placebo in acute coronary syndromes. METHODS: This meta-analysis followed the Cochrane collaboration guidelines and the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) protocols. Outcomes of interest included all-cause mortality, myocardial infarction, stent thrombosis, target vessel revascularization, major bleeding, minor bleeding, and the need for blood transfusion. RESULTS: The analysis was comprised of 6 studies including 26,444 patients treated with cangrelor, clopidogrel, or placebo. There were no statistically significant differences in the incidence of all-cause mortality, myocardial infarction, stent thrombosis, target vessel revascularization, or major bleeding. Cangrelor was associated with a higher risk of minor bleeding than clopidogrel or placebo, with no difference in requiring blood transfusion. CONCLUSION: Cangrelor has comparable outcomes to clopidogrel in patients with acute coronary syndromes and can be used as a reliable alternative in this population.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Humanos , Clopidogrel/uso terapéutico , Síndrome Coronario Agudo/terapia , Inhibidores de Agregación Plaquetaria/efectos adversos , Metaanálisis en Red , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Adenosina Monofosfato/efectos adversos , Infarto del Miocardio/tratamiento farmacológico , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Hemorragia/tratamiento farmacológico , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Trombosis/tratamiento farmacológico
9.
Am J Cardiol ; 220: 102-110, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38432334

RESUMEN

Proximal radial artery (PRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (DRA) access in the anatomical snuffbox preserves the RA but safety and potential detrimental effects on hand function are unknown. We aimed to assess hand function and complications after DRA and PRA. In this single-center trial, 300 patients were randomly allocated 1:1 to cardiac catheterization through DRA or PRA. The primary end point of change in hand function from baseline to 1 year was a composite of the Quick Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, hand grip test, and thumb-forefinger pinch test. The secondary end points included access feasibility and complications. Of 216 patients with 1-year completed follow-up, 112 were randomly allocated to DRA and 104 to PRA, with balanced demographics and procedural characteristics. Both groups had similar access site bleeding rates (DRA 0% vs PRA 1.4%, p = 0.25). Radial artery occlusion occurred in 1 PRA patient versus 2 in DRA. There was no significant difference in change of hand function, median (interquartile range) hand grip (DRA 0.7 [-3 to 4.5] vs PRA 1.3 [-2 to 4.3] kg, p = 0.57), pinch grip (DRA -0.1 [-1.1 to 1] vs PRA -0.3 [-1 to 0.7] kg, p = 0.66), and Quick DASH (DRA 0 [-6.6 to 2.3] vs PRA 0 [-4.6 to 2.9] points, p = 0.58). The composite of hand function was comparable between PRA and DRA. In conclusion, DRA is a safe strategy for cardiac catheterization, with a low complication rate. Compared with PRA, there is no increased risk of hand dysfunction or radial artery occlusion at 1 year.


Asunto(s)
Cateterismo Cardíaco , Arteria Radial , Humanos , Masculino , Femenino , Cateterismo Cardíaco/métodos , Persona de Mediana Edad , Anciano , Fuerza de la Mano/fisiología , Estudios de Seguimiento , Factores de Tiempo
10.
JACC Cardiovasc Interv ; 17(17): 2041-2051, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39177555

RESUMEN

BACKGROUND: A prior Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry-based analysis reported similar 1-year clinical outcomes with small (20-mm) vs large (≥23-mm) balloon-expandable valves (BEV). OBJECTIVES: The aim of this study was to describe mid-term 3-year clinical outcomes for small vs large BEV and the relationship between discharge echocardiographic mean gradient (MG) and different definitions of prothesis-patient mismatch (PPM) with clinical outcomes. METHODS: Using the TVT Registry with Centers for Medicare and Medicaid Services linkage, a propensity-matched analysis of patients receiving 20- vs ≥23-mm BEVs was performed. Spline curves and Kaplan-Meier plots with adjusted HRs determined the relationship between MG and 3-year mortality. RESULTS: In total, 316,091 patients were analyzed; after propensity matching, 8,100 pairs of each group were compared. The 20-mm BEV was associated with higher MGs compared with ≥23-mm BEVs (16.2 ± 7.2 mm Hg vs 11.8 ± 5.7 mm Hg; P < 0.0001). At 3 years, there was no difference in mortality between 20- and ≥23-mm BEVs (31.5% vs 32.5%, respectively; HR: 0.97; 95% CI: 0.90-1.05). Compared with an MG of 10 to 30 mm Hg, an MG <10 mm Hg (HR: 1.25; 95% CI:1.22-1.27) was associated with increased 3-year mortality. Measured severe PPM and predicted no PPM were associated with increased 3-year mortality (33.5% vs 32.9% vs 32.1%; P < 0.0001) and (33.5% vs 31.1% vs 30%; P < 0.0001), respectively. Low MG and severe measured PPM were associated with lower left ventricular ejection fraction (LVEF). CONCLUSIONS: Patients with small-prosthesis BEVs (20 mm) had identical 3-year survival as those with larger (≥23-mm) BEV valves. Severe measured PPM and low MG (<10 mm Hg), but not predicted severe PPM, were associated with lower LVEF and increased mortality, suggesting that LVEF is the culprit for worse outcomes.


Asunto(s)
Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Humanos , Masculino , Femenino , Factores de Tiempo , Resultado del Tratamiento , Anciano , Factores de Riesgo , Estados Unidos , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/efectos adversos , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Medición de Riesgo , Hemodinámica , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Recuperación de la Función , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad
11.
Proc (Bayl Univ Med Cent) ; 37(2): 218-226, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38343489

RESUMEN

Background: In March 2022, a COVID-19 outbreak disrupted the global supply of iodine contrast media (ICM). Healthcare systems implemented contrast-saving strategies to maintain their remaining ICM supplies. This study sought to determine the impact of contrast shortage on the incidence of contrast-associated acute kidney injury (CA-AKI). Methods: This was a retrospective study of 265 patients undergoing 278 percutaneous coronary interventions (PCI) during 4-month periods prior to (9/1/2021 to 12/31/2021) and during (5/1/2022 to 8/31/2022) contrast shortage at a single center. The primary endpoint was the incidence of CA-AKI between study periods. Results: A total of 148 and 130 PCIs were performed before and during contrast shortage, respectively. The incidence of CA-AKI significantly decreased from 11.5% to 4.6% during contrast shortage (P = 0.04). During the shortage, average contrast volume per PCI was significantly lower (123 ± 62 mL vs 88 ± 46 mL, P < 0.001), while coronary imaging was significantly higher (34.3% vs 50%, P = 0.009) compared to preshortage. All-cause mortality at discharge was comparable between study periods (2.8% vs 3.3%, respectively; P = 0.90). Conclusion: The scarcity of ICM for PCI procedures in this single-center experience was associated with a significant increase in the utilization of intravascular imaging and a significant reduction in CA-AKI.

12.
Am J Cardiol ; 231: 11-19, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39209242

RESUMEN

Data on the long-term outcomes of prosthesis patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) remain controversial. This study aimed to investigate the incidence and clinical outcomes of measured PPM (PPMM) and predicted PPM (PPMP) in patients who underwent TAVI. This is a retrospective analysis of 3,016 patients who underwent TAVI at a large health care system between 2012 and 2021. Effective orifice area indexed to body surface area (EOAi) was measured at discharge using the continuity equation. EOAi was predicted according to the published predictive tables for each model and size of the valve. Primary end point was 5-year survival rate. Mean age was 80 years, and 55.6% were male. The mean Society of Thoracic Surgeons risk score was 4.66%. 74.9% of patients received a balloon-expandable valve (BEV), and 25.1% received a self-expanding valve (SEV). The incidence of severe PPM was markedly lower when defined by predicted versus measured EOAi (0.8% vs 6.3%, p <0.001) and when assessed in SEV versus BEV (5.3% vs 6.6%, p = 0.02). Neither severe PPMp nor severe PPMM was associated with 5-year mortality (hazard ratio 1.26, 95% confidence interval 0.96 to 1.66, p = 0.095; hazard ratio 1.03, 95% confidence interval 0.42 to 2.49, p = 0.954, respectively), irrespective of the presence of high residual pressure gradient. Neither BEV nor SEV was associated with an increased 5-year mortality, irrespective of PPM definition or severity. In this large health care system analysis, neither severe PPMP nor severe PPMM was associated with 5-year all-cause mortality. There was no difference between BEV and SEV in terms of mortality, irrespective of the definition or severity of PPM.

13.
Proc (Bayl Univ Med Cent) ; 36(2): 213-215, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36876240

RESUMEN

We report a patient with Ebstein's anomaly, on chronic milrinone therapy for right ventricular failure, who underwent palliative percutaneous closure of her atrial septal defect (ASD) due to recurring strokes. Repeated evaluation of right-sided pressures was performed prior to ASD closure to determine if our patient could tolerate the intervention. Definitive ASD closure was performed under fluoroscopic and transesophageal echocardiogram guidance.

14.
J Am Soc Echocardiogr ; 36(12): 1302-1314, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37507058

RESUMEN

BACKGROUND: The role of echocardiography in deriving transvalvular mean gradients from transaortic velocities in aortic stenosis (AS) and in structural valve degeneration (SVD) is well established. However, reports following surgical aortic valve replacement, post-transcatheter aortic valve replacement (TAVR), and valve-in-valve-TAVR (ViV-TAVR) have cautioned against the use of echocardiography-derived mean gradients to assess normal functioning bioprosthesis due to discrepancy compared with invasive measures in a phenomenon called discordance. METHODS: In a multicenter study, intraprocedural echocardiographic and invasive mean gradients in AS, SVD, post-native TAVR, and post-ViV-TAVR were compared, when obtained concomitantly, and discharge echocardiographic gradients were recorded. Absolute discordance (intraprocedural echocardiographic - invasive mean gradient) and percent discordance (intraprocedural echocardiographic - invasive mean gradient/echocardiographic mean gradient) were calculated. Multivariable regression analysis was performed to determine variables independently associated with elevated postprocedure invasive gradients ≥20 mm Hg, absolute discordance >10 mm Hg, and discharge echocardiographic mean gradient ≥20 mm Hg. RESULTS: A total of 5,027 patients were included in the registry: 4,725 native TAVR and 302 ViV-TAVR. Intraprocedural concomitant echocardiographic and invasive mean gradients were obtained pre-TAVR in AS (n = 2,418), pre-ViV-TAVR in SVD (n = 101), in post-ViV-TAVR (n = 77), and in post-TAVR (n = 823). Echocardiographic and invasive mean gradients demonstrated strong correlation (r = 0.69) and agreement (bias, 0.11; 95% CI, -0.4-0.62) in AS, moderate correlation (r = 0.56) and agreement (bias, 1.08; 95% CI, -2.53 to 4.59) in SVD, moderate correlation (r = 0.61) and weak agreement (bias, 6.47; 95% CI, 5.08-7.85) post-ViV-TAVR, and weak correlation (r = 0.18) and agreement (bias, 3.41; 95% CI, 3.16-3.65) post-TAVR. Absolute discordance occurs primarily in ViV-TVR and is not explained by sinotubular junction size and increases with increasing echocardiographic mean gradient. Percent discordance in AS and SVD (1.3% and 4%, respectively) was lower compared with post-TAVR/ViV-TAVR (66.7% and 100%, respectively). Compared with self-expanding valves, balloon expanding valves were independently associated with elevated discharge echocardiographic but lower invasive mean gradient (odds ratio = 3.411, 95% CI, 1.482-7.852, P = .004; vs odds ratio = 0.308, 95% CI, 0.130-0.731, P = .008, respectively). CONCLUSIONS: Post-TAVR/ViV-TAVR, echocardiography is discordant from invasive mean gradients, and absolute discordance increases with increasing echocardiographic mean gradient and is not explained by sinotubular junction size. Percent discordance is significantly higher post-TAVR/ViV-TAVR than in AS and SVD. Post-TAVR/ViV-TAVR, poor correlation and wide limits of agreement suggest echocardiographic and invasive mean gradients may not be used interchangeably and a high residual echocardiographic mean gradient should be confirmed invasively before considering any additional procedure to "correct" the gradient. Transcatheter aortic valve replacement valve types have variable impact on echocardiographic and invasive mean gradients.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía
15.
Am J Cardiovasc Dis ; 13(5): 291-299, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38026111

RESUMEN

INTRODUCTION: The first-generation Watchman 2.5 (W 2.5)TM presented several limitations, such as challenges in implantation within complex left atrial appendage (LAA) anatomies, higher incidence of peri-device leak, device recapture, and device-related thrombus (DRT). The newer generation Watchman FLX (W-FLX)TM was introduced with a modified design aiming to overcome these limitations. The purpose of this meta-analysis is to conduct a comparative assessment of the safety and efficacy of the W-FLX and 2.5 devices in clinical practice. METHOD: The meta-analysis was conducted according to the preferred reporting items for systematic review and meta-analysis protocols (PRISMA). Studies were located through a search strategy utilizing PubMed, Cochrane, Google scholar and MEDLINE from inception to March 2023, with a primary objective to compare the safety and efficacy of the W-FLX and W 2.5 devices. After applying the selection criteria, five studies were included in this analysis. RESULTS: The analysis included five studies comprising 54,727 patients. The W-FLX is associated with an increase in procedural success (OR 7.49 [95% CI 1.98-28.26, P = 0.02; I2 = 0%]), and a significant reduction in mortality (OR 0.52 [95% CI 0.51-0.54, P<0.01; I2 = 0%], major bleeding 0.57 [95% CI 0.51-0.64, P<0.01; I2 = 0%]), device embolism (OR 0.35 [95% CI 0.18-0.70, P = 0.02; I2 = 0%]), and pericardial effusion (OR 0.33 [95% CI 0.26-0.41, P<0.01; I2 = 0%]). The rates of DRT and stroke were similar between the two groups. CONCLUSION: Compared to the W 2.5, the W-FLX was associated with a higher procedural success rate and significantly reduced adverse outcomes including mortality, major bleeding, device embolization, and pericardial effusion.

16.
J Soc Cardiovasc Angiogr Interv ; 2(4): 100971, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39131655

RESUMEN

Stent failure remains the major drawback to the use of coronary stents as a revascularization strategy. Recent advances in imaging have substantially improved our understanding of the mechanisms underlying these occurrences, which have in common numerous clinical risk factors and mechanical elements at the time of stent implantation. In-stent restenosis remains a common clinical problem despite numerous improvements in-stent design and polymer coatings over the past 2 decades. It generates significant health care cost and is associated with an increased risk of death and rehospitalization. Stent thrombosis causes abrupt closure of the stented artery and therefore carries a high risk of myocardial infarction and death. This Society for Cardiovascular Angiography & Interventions (SCAI) Expert Consensus Statement suggests updated practical algorithmic approaches to in-stent restenosis and stent thrombosis. A pragmatic outline of assessment and management of patients presenting with stent failure is presented. A new SCAI classification that is time-sensitive with mechanistic implications of in-stent restenosis is proposed. Emphasis is placed on frequent use of intracoronary imaging and assessment of timing to determine the precise etiology because that information is crucial to guide selection of the best treatment option. SCAI recommends image-guided coronary stenting at the time of initial implantation to minimize the occurrence of stent failure. When in-stent restenosis and stent thrombosis are encountered, imaging should be strongly considered to optimize the subsequent approach.

17.
JACC Cardiovasc Interv ; 16(24): 2999-3012, 2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-37902146

RESUMEN

BACKGROUND: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies. OBJECTIVES: The authors sought to compare the 1-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in ViV-TAVR. METHODS: Patients with a failed small (≤23 mm) surgical valve undergoing ViV-TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 1-year follow-up. Study outcomes were defined according to VARC-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient <20 mm Hg, peak velocity <3 m/s, Doppler velocity index ≥0.25 and less than moderate AR. RESULTS: A total of 98 patients underwent ViV-TAVR (46 BEV, 52 SEV). At 1-year follow-up, patients receiving a SEV had a lower mean transaortic gradient (22 ± 8 mm Hg BEV vs 14 ± 7 mm Hg SEV; P < 0.001), and a higher rate of intended valve performance (BEV: 30%, SEV:76%; P < 0.001). There were no cases of greater than mild aortic regurgitation. There were no differences in functional status (NYHA functional class >II, BEV: 7.3%, SEV: 4.1%; P = 0.505) or quality of life (Kansas City Cardiomyopathy Questionnaire, BEV: 77.9 ± 21.2, SEV: 81.8 ± 14.8; P = 0.334). No differences in all-cause mortality (BEV: 6.5%, SEV: 3.8; P = 0.495), heart failure hospitalization (BEV: 6.5%, SEV: 1.9%; P = 0.214), stroke (BEV: 0%, SEV: 1.9%; P = 0.369), myocardial infarction (BEV: 0%, SEV: 1.9%; P = 0.347), or pacemaker implantation (BEV: 2.2%, SEV: 1.9%; P = 0.898) were found. CONCLUSIONS: In patients who underwent ViV-TAVR for failed small aortic bioprostheses, those receiving a SEV exhibited a better valve hemodynamic profile at 1-year follow-up. There were no differences between SEV and BEV regarding functional status, quality of life, or clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Calidad de Vida , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Diseño de Prótesis
18.
J Am Heart Assoc ; 12(21): e030774, 2023 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-37889176

RESUMEN

Background Proximal radial artery (pRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (dRA) access in the anatomical snuffbox preserves the radial artery, but safety and potential detrimental effects on hand function are unknown. Methods and Results In the DIPRA (Distal Versus Proximal Radial Artery Access for Cardiac Catheterization and Intervention) study, a single-center trial, 300 patients were randomized 1:1 to cardiac catheterization through dRA or pRA. The primary end point of change in hand function from baseline to 30 days was a composite of the QuickDASH (Quick Disabilities of the Arm, Shoulder and Hand) questionnaire, hand-grip test, and thumb forefinger pinch test. Secondary end points included access feasibility and complications; 254 of 300 patients completed follow-up at 30 days; of these, 128 were randomized to dRA and 126 to pRA with balanced demographic and procedural characteristics. Both groups had similar rates of access site bleeding (dRA 0% versus pRA 1.4%; P=0.25). Six patients with dRA failed access compared with 2 patients with pRA. Radial artery occlusion occurred in 2 pRA versus none in dRA. There were no significant differences in change in hand function, median hand-grip (dRA 0 [-3.2, 3.3] versus pRA 0.7 [-2.3, 3.3] kg; P=0.21), pinch-grip (dRA -0.3 [-1.2, 0.5] versus pRA 0 [-0.9, 0.9] kg; P=0.09), and QuickDASH (dRA 0 [-4.6, 2.3] versus pRA 0 [-4.6, 2.3] points, P=0.96). There was no significant difference in the composite of hand function between pRA and dRA. Conclusions dRA is a safe strategy for cardiac catheterization with a low complication rate. Compared with pRA, there is no increased risk of hand dysfunction at 30 days. Registration URL: https://www.ClinicalTrials.gov. Unique identifier: NCT04318990.


Asunto(s)
Arteriopatías Oclusivas , Intervención Coronaria Percutánea , Humanos , Arteria Radial , Muñeca , Cateterismo Cardíaco/efectos adversos , Angiografía Coronaria/métodos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
19.
J Soc Cardiovasc Angiogr Interv ; 2(3): 100600, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39130722

RESUMEN

Background: The Society of Thoracic Surgeons (STS) score has been used to risk stratify patients undergoing transcatheter aortic valve replacement (TAVR). The Transcatheter Valve Therapy (TVT) score was developed to predict in-hospital mortality in high/prohibitive-risk patients. Its performance in low and intermediate-risk patients is unknown. We sought to compare TVT and STS scores' ability to predict clinical outcomes in all-surgical-risk patients undergoing TAVR. Methods: Consecutive patients undergoing TAVR from 2012-2020 within a large health care system were retrospectively reviewed and stratified by STS risk score. Predictive abilities of TVT and STS scores were compared using observed-to-expected mortality ratios (O:E) and area under the receiver operating characteristics curves (AUCs) for 30-day and 1-year mortality. Results: We assessed a total of 3270 patients (mean age 79 ± 9 years, 45% female), including 191 (5.8%) low-risk, 1093 (33.4%) intermediate-risk, 1584 (48.4%) high-risk, and 402 (5.8%) inoperable. Mean TVT and STS scores were 3.5% ± 2.0% and 6.1% ± 4.3%, respectively. Observed 30-day and 1-year mortality were 2.8% (92/3270; O:E TVT 0.8 ± 0.16 vs STS 0.46 ± 0.09), and 13.2% (432/3270), respectively. In the all-comers population, both TVT and STS risk scores showed poor prediction of 30-day (AUC: TVT 0.68 [0.62-0.74] vs STS 0.64 [0.58-0.70]), and 1-year (AUC: TVT 0.65 [0.62-0.58] vs STS 0.65 [0.62-0.58]) mortality. After stratifying by surgical risk, discrimination of the TVT and STS scores remained poor in all categories at 30 days and 1 year. Conclusions: An updated TAVR risk score with improved predictive ability across all-surgical-risk categories should be developed based on a larger national registry.

20.
J Invasive Cardiol ; 35(7): E329-E340, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37769619

RESUMEN

BACKGROUND: Although discouraged, ad hoc chronic total occlusion (CTO) percutaneous coronary intervention (PCI) is occasionally performed. METHODS: We examined the clinical, angiographic characteristics, and procedural outcomes of patients who underwent ad hoc CTO PCI in the Prospective Global Registry for the Study of CTO Intervention (PROGRESS-CTO, NCT02061436). RESULTS: Of the 10,998 patients included in the registry, 899 (8.2%) underwent ad hoc CTO PCI. The incidence of ad hoc CTO PCI decreased from 18% in 2016 to 3% in 2022. Ad hoc CTO PCI patients had a lower prevalence of comorbidities and less complex angiographic characteristics demonstrated by lower J-CTO score (1.9±1.2 vs 2.4±1.3, P < .001). In these patients, PROGRESS-CTO major adverse cardiovascular events (MACE) (1.9±1.4 vs 2.5±1.7), mortality (1.2±1.0 vs 1.6±1.1), and perforation (1.5±1.2±2.2 vs 1.5) scores were lower (P < .001). Technical success was similar between the groups (86%). MACE were lower in the ad hoc CTO PCI group (.8% vs 2.0%, P=.009). Ad hoc CTO PCI was not associated with MACE after adjusting for potential confounders, odds ratio: .69 (95% confidence interval, .30-1.57). In patients with higher J-CTO scores, planned CTO PCI was associated with higher technical success (P < .001). CONCLUSION: Approximately 8% of CTO PCI procedures are performed ad hoc, usually in less complex lesions and patients with lower complication risk. While ad hoc CTO PCI might be appropriate for carefully selected cases, a staged approach is recommended for most CTO PCI.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Angiografía Coronaria/métodos , Sistema de Registros , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/epidemiología , Oclusión Coronaria/cirugía , Enfermedad Crónica , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA