Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
JACC Clin Electrophysiol ; 10(1): 68-78, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37897465

RESUMEN

BACKGROUND: Injury to the esophagus has been reported in a high percentage of patients undergoing ablation of atrial fibrillation (AF). OBJECTIVES: This study assessed the incidence of esophageal injury in patients undergoing ablation of AF with and without an esophageal deviating device. METHODS: This prospective, randomized, multicenter, double-blinded, controlled Food and Drug Administration investigational device exemption trial compared the incidence of ablation-related esophageal lesions, as assessed by endoscopy, in patients undergoing AF ablation assigned to a control group (luminal esophageal temperature [LET] monitoring alone) compared with patients randomized to a deviation group (esophagus deviation device + LET). This novel deviating device uses vacuum suction and mechanical deflection to deviate a segment of the esophagus, including the trailing edge. RESULTS: The data safety and monitoring board recommended stopping the study early after randomizing 120 patients due to deviating device efficacy. The primary study endpoint, ablation injury to the esophageal mucosa, was significantly less in the deviation group (5.7%) in comparison to the control group (35.4%; P < 0.0001). Control patients had a significantly higher severity and greater number of ablation lesions per patient. There was no adverse event assigned to the device. By multivariable analysis, the only feature associated with reduced esophageal lesions was randomization to deviating device (OR: 0.13; 95% CI: 0.04-0.46; P = 0.001). Among control subjects, there was no difference in esophageal lesions with high power/short duration (31.8%) vs other radiofrequency techniques (37.2%; P = 0.79). CONCLUSIONS: The use of an esophageal deviating device resulted in a significant reduction in ablation-related esophageal lesions without any adverse events.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Ablación por Radiofrecuencia , Humanos , Estudios Prospectivos , Ablación por Catéter/métodos , Esófago/cirugía
2.
Am J Med ; 131(2): 202-205, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28860031

RESUMEN

BACKGROUND: Stress cardiomyopathy is a transient cardiac syndrome characterized by reversible left ventricular systolic dysfunction precipitated by emotional or physiologic stress. The presence of obstructive coronary artery disease has been noted in stress cardiomyopathy. METHODS: We describe 3 case reports of patients with acute coronary syndrome and transient wall motion abnormalities not usually seen in the distribution of coronary artery disease. RESULTS: In these 3 cases of acute myocardial infarction, the distribution of the culprit coronary occlusion was not concordant with the territory of transient wall motion abnormality. Follow-up demonstrated resolution of the wall motion abnormalities without intervention in these territories. CONCLUSION: We believe that the physiologic stress of the acute coronary syndrome may have precipitated the stress cardiomyopathy as presented by these patients. This is the first demonstration that stress cardiomyopathy may be precipitated by acute coronary syndrome.


Asunto(s)
Infarto del Miocardio/complicaciones , Cardiomiopatía de Takotsubo/complicaciones , Anciano , Anciano de 80 o más Años , Oclusión Coronaria/complicaciones , Oclusión Coronaria/terapia , Reestenosis Coronaria/complicaciones , Reestenosis Coronaria/terapia , Femenino , Humanos , Infarto del Miocardio/fisiopatología , Estrés Fisiológico , Estrés Psicológico , Cardiomiopatía de Takotsubo/fisiopatología , Cardiomiopatía de Takotsubo/psicología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA