Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Contemp Dent Pract ; 25(1): 72-78, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38514435

RESUMEN

AIM: In comparing the effectiveness and efficiency of different types of post removal systems in removing different types of fiber posts (FPs), this study aims to shed light on the success of removal by currently available drill systems. MATERIALS AND METHODS: A total of 200 maxillary first molars, were root canal treated and prepared to receive posts. The molars were divided into four groups corresponding to four different FPs: Group RX, Radix FP; Group RF, Reforpost Glass Fiber; Group HI; Hi-Rem Endodontic Post; and Group DT, D.T. Light-Post Illusion X-RO. Fiber posts were done with luting by Gradia Core (GC America, Inc.). Groups were again divided into five subgroups corresponding to the technique by which the FP was removed into as follows: Subgroup P, PD-25-1.1 Drill; subgroup G, GC FP Drill; subgroup E, EasyPost Precision Drill; subgroup R, Reaccess Carbide Double Taper Kit; and subgroup H; H-Endodontic Drill. After posts were removed, effectiveness and efficiency were documented. Data were tabulated and statistically analyzed. RESULTS: Strong significant differences regarding efficiency among groups (FP type) and subgroups (drills used) (p = 0.00) were shown by the one-way analysis of variance (ANOVA) test. Subgroup DT-G scored the longest mean removal time (20.9 minutes) while Subgroup RX-R scored the shortest mean removal time (1.4 minutes) Regarding effectiveness, strong significant differences among groups (p = 0.00) and subgroups (p = 0.00) were shown by one-way ANOVA. Subgroup RF-G scored the highest scale (5.2) whereas subgroup HI-R scored the lowest mean scale (1.2). CONCLUSION: The difference was strongly significant between tested post-removal kits and between tested FPs. Re-access Carbide Double Taper Kit performed superiorly in both effectiveness and efficiency, followed by PD-25-1.1 Drill. Hi-Rem post showed the best retrieving results among other FPs. CLINICAL SIGNIFICANCE: Knowing the best technique and tools for post removal could spare the practitioner any unwanted complications during post removal. How to cite this article: Sayed M, Alahmad AM, Alhajji KS, et al. Removal Efficiency and Effectiveness of Four Different Fiber Posts Using Five Different Drill Systems in Multirooted Teeth. J Contemp Dent Pract 2024;25(1):72-78.


Asunto(s)
Técnica de Perno Muñón , Diente no Vital , Humanos , Tratamiento del Conducto Radicular , Diente no Vital/terapia , Vidrio , Ensayo de Materiales , Cementos de Resina , Análisis del Estrés Dental
2.
Can Assoc Radiol J ; 73(1): 259-270, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33886403

RESUMEN

OBJECTIVES: The purpose of this article is to review the embryology of the lower limb arterial anatomy along with common variants and their clinical relevance. DESIGN: Embryologic variations of the lower limb arterial system may be explained by i.) persistence of primordial arterial segments, ii.) abnormal fusion, iii.) segmental hypoplasia/absence, or a combination of both. Persistent sciatic artery, corona mortis, and popliteal entrapment syndrome will also be discussed with associated symptoms, and potential complications. CONCLUSION: Knowledge of these variations is essential for surgical and endovascular management as failure to recognize them can result in complications.


Asunto(s)
Arterias/embriología , Extremidad Inferior/irrigación sanguínea , Arterias/anomalías , Arterias/anatomía & histología , Femenino , Humanos , Masculino
3.
Catheter Cardiovasc Interv ; 95(1): 45-53, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31038290

RESUMEN

OBJECTIVES: To demonstrate safety, feasibility and short-term clinical outcomes after transcatheter aortic valve-in-valve (ViV) implantation under local anesthesia without contrast aortography or echocardiographic guidance. BACKGROUND: Transcatheter ViV implantation is an emerging treatment modality for patients with degenerative surgical bioprostheses. Given the radiopaque properties of the surgical aortic valve (SAV) frame, ViV procedures can often be performed with fluoroscopic guidance alone. METHODS: ViV implantation was performed in 37 patients with SAV failure under local anesthesia without contrast aortography. Clinical and echocardiographic data were obtained at baseline, discharge, and 30 days. RESULTS: Mean age was 74 ± 10 years and STS predicted risk of mortality was 5.6 ± 2.4%. Mean transaortic gradient decreased from 39.4 ± 15.5 mmHg to 13 ± 6.3 mmHg at discharge (p < .001), and 20 ± 7.5 mmHg at 30 days (p < .001 compared to baseline), aortic valve area increased from 0.9 ± 0.3 cm2 to 1.2 ± 0.4 cm2 at 30 days (p = .007). No patient had more than mild aortic regurgitation. Hospital discharge occurred at a median of 2.6 ± 4.4 days. At 30-day follow-up there were no deaths, myocardial infarctions, strokes, repeat hospital admissions for heart failure, or renal failure. One patient (2.7%) required a new pacemaker. 93% of the patients were in New York Heart Association functional class I or II. CONCLUSIONS: Transcatheter aortic ViV implantation for selected patients with degenerative surgical bioprostheses under local anesthesia without aortography or echocardiographic guidance is feasible and safe.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Anestesia Local , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
4.
Echo Res Pract ; 11(1): 21, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39129021

RESUMEN

BACKGROUND: The development of heart failure is a turning point in the natural course of aortic stenosis (AS). Pulmonary oedema and elevated left ventricular pressure (LVP) are cardinal features of heart failure. Evaluating pulmonary oedema by lung ultrasound involves taking the upper hand with a bedside noninvasive tool that may reflect LVP. AIM: We sought to assess the correlation between sonographic pulmonary congestion, invasive LV pre-A pressure, and echocardiographic LV end-diastolic pressure (LVEDP) in symptomatic AS patients receiving transcatheter aortic valve replacement. METHODS: Forty-eight consecutive patients with severe AS and planned transcatheter aortic valve implantation (TAVI) were enrolled. LVEDP was estimated to be normal or elevated using the ASE/EACVI algorithm and transmitral Doppler indices, the E/A ratio, the E/e', and the left atrial volume index. Invasive LV pre-A pressure was used as a reference, with > 12 mm Hg defined as elevated. RESULTS: Forty-eight patients (25 women (52%), mean age 75 years, standard deviation (SD) ± 7.7 years) were enrolled in the study. We detected severe B-lines (≥ 30) in 13 (27%) patients and moderate B-lines (15-30) in 33 (68.6%) patients. The number of B-lines increased significantly with the severity of New York Heart Association (NYHA) functional classes (Fig. 1). The B-line count was 14 ± 13 in NYHA class I patients, 20 ± 20 in class II patients, and 44 ± 35 in class III patients (p < 0.05, rho = 0.384). The number of B-lines was correlated with the E/E' ratio (R = 0.664, p < 0.0001) and the proBNP level (R = 0. 882, p < 0.008). We found no significant correlation with the LVEDP or LVEF. The LVEDP correlated well with the E/E' ratio (R = 0.491, p < 0.001) but not at all with E/A, DT, or LAVI. All patients had an elevated LVEDP > 12, with a mean pressure of 26 mmHg, a minimum of 13 mmHg, and a maximum of 45 mmHg, with an SD of 7.85. CONCLUSION: Assessing lung ultrasonic B-lines is a straightforward and practical approach to identifying pulmonary oedema in AS patients. The number of B-lines correlated with the E/E' ratio and the functional status of patients but did not correlate with invasive LVEDP or LVEF. All patients had elevated LVEDP that correlated with E/E'.

5.
Int J Surg Case Rep ; 112: 108934, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37925784

RESUMEN

INTRODUCTION AND IMPORTANCE: This case report is intended to present an unusual cause of urinary retention by a congenital vaginal obstruction, such as hematocolpos. Hematocolpos is an obstruction of the menstrual flow due to an anomaly of the genital tract, with imperforate hymen being the most common one. CASE PRESENTATION: A 12-year-old female patient, was referred to our emergency department for recurrent abdominal pain lasting approximately 90 days. She presented with intermittent dysuria and supra pubic fullness. Ultrasonography confirmed acute urinary retention and features of hematocolpos [7]. CLINICAL DISCUSSION: High index of suspicion is necessary to diagnose and treat such patients promptly. Patients usually present with cyclic pain, primary amenorrhea, incomplete emptying of urine, chronic constipation, back pain and recurrent urinary tract infections. Our patient presented with acute urinary retention. CONCLUSION: This case report highlights the importance of early recognition of hematocolpos as a potential cause of cyclic pain, and urinary symptoms. Prompt and accurate diagnosis with the appropriate surgical managements, to resolve their symptoms with successful outcomes.

6.
Indian Heart J ; 75(4): 268-273, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37406856

RESUMEN

OBJECTIVE: Permanent pacemaker implantation (PPI) risk is higher following transcatheter aortic valve implantation (TAVI) than surgical valve replacement. Native aortic leaflets are retained in patients undergoing TAVI, unlike in surgical valve replacement. Whether the retained leaflets influence PPI risk because of their proximity to the conduction system is unknown. The study sought to determine the association between infra-annular extension of native right coronary cusp/noncoronary cusp (RCC/NCC) post balloon-expandable TAVI and PPI risk. METHODS: We performed a retrospective analysis of 190 patients undergoing balloon-expandable TAVI at a single center. Manifestation of infra-annular extension of RCC/NCC was considered to be present when part of leaflet extended below aortic-annular plane on post-implantation aortic-root angiography. RESULTS: Infra-annular extension of RCC/NCC was observed in 33 patients (17.37%). PPI incidence post-TAVI was higher in patients with infra-annular extension of RCC/NCC than in those without (36.36% versus 8.92%, relative-risk: 4.08, p˂0.0001). On logistic-regression analysis, preexisting right bundle-branch block (RBBB) (odds-ratio: 12.73, 95% confidence-interval: 2.16-74.93, p = 0.005), and infra-annular extension of RCC/NCC (odds-ratio: 5.63, 95% confidence-interval: 2.17-14.58, p < 0.0001) were independently associated with PPI risk. Preexisting RBBB (φ = +0.25, p = 0.001) and infra-annular extension of RCC/NCC (φ = +0.30, p < 0.0001) showed a positive-correlation with PPI risk. Infra-annular extension of RCC/NCC was a significant predictor of PPI risk on receiver-operating-characteristic curve analysis (area under-the-curve 0.67; 95% confidence-interval: 0.54-0.79, p = 0.006). CONCLUSION: The retained native aortic leaflets play a significant role in PPI risk following balloon-expandable TAVI. Infra-annular extension of RCC/NCC is a novel predictor, and is associated with a four-fold higher risk of PPI.


Asunto(s)
Estenosis de la Válvula Aórtica , Carcinoma de Células Renales , Prótesis Valvulares Cardíacas , Neoplasias Renales , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Carcinoma de Células Renales/complicaciones , Carcinoma de Células Renales/cirugía , Estimulación Cardíaca Artificial/efectos adversos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Bloqueo de Rama/terapia , Neoplasias Renales/complicaciones , Neoplasias Renales/cirugía , Factores de Riesgo
7.
BMJ Open ; 13(9): e073549, 2023 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-37730395

RESUMEN

BACKGROUND: Severe mitral regurgitation (MR) with left ventricular dysfunction portends worse outcomes. Over the course of the last two decades, transcatheter repair of the mitral valve offered an alternative therapeutic modality for those deemed inoperable or high risk. Landmark studies such as the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation and Multicentre Study of Percutaneous Mitral Valve Repair MitraClip Device in Patients With Severe Secondary Mitral Regurgitation trials have shown conflicting results with respect to all-cause death and heart failure rehospitalisations. The Gulf Mitral Transcatheter Edge to Edge Repair registry (Gulf MTEER registry) is a regional registry that captured outcomes in those undergoing transcatheter repair of the mitral valve. The objectives of this study were to describe the baseline characteristics of patients undergoing transcatheter mitral valve repair in the Gulf region and estimate the cardiovascular effects of the mitral transcatheter therapies in routine practice. METHODS: The Gulf MTEER registry is an observational, multicentre, retrospective registry that enrolled all patients undergoing transcatheter repair of the mitral valve from four of the Gulf countries (Saudi Arabia, Kuwait, Bahrain, Oman) between 1 January 2017 and 31 December 2019. Baseline characteristics, echocardiographic parameters and immediate procedural success were reported. The primary outcome was a composite of death and rehospitalisations at 1 year. The secondary outcomes were the individual components of the composite endpoint; that is, death and rehospitalisations at 1 year as well as residual or recurrent MR or worsening New York Heart Association class and a need for repeat repair. RESULTS: A total of 176 patients were enrolled. Men constituted 56.3% of the total. At 1 year the primary outcome occurred in 21.1% (95% CI 15.6, 27.9). The secondary outcomes of death occurred in 5.4% (CI 2.9, 10.0) and rehospitalisations occurred in 16.9% (CI 11.9, 23.3). Univariate analysis revealed that the odds of having death or re-hospitalisation was two times higher if the effective regurgitant orifice (ERO) >40 mm2 irrespective of the therapy. CONCLUSIONS: The Gulf MTEER registry is the first registry in the Gulf region defining the patient population receiving MTEER therapies and evaluating 1-year outcomes. This is a low risk cohort with a high rate of immediate procedural success and low rate of all-cause death and rehospitalisations at 1 year. The odds of an event was two times higher if the ERO ≥40 mm2 with only a signal to higher odds for low left ventricular ejection fraction and larger end systolic dimension.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda
8.
JRSM Open ; 13(12): 20542704221132135, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36506267

RESUMEN

Transcatheter aortic valve replacement (TAVR) is an alternative treatment for selected patients with severe aortic valve stenosis who are at high risk for conventional surgery. Critical stenosis of left main coronary artery as a late complication after TAVR is quite rare.

9.
Cardiovasc Revasc Med ; 41: 19-26, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35033460

RESUMEN

BACKGROUND: The use of transcatheter aortic valve replacement (TAVR) is steadily increasing with TAVR procedures offered to patients across the entire spectrum of surgical risks. The Gulf TAVR registry captures the demographics of patients undergoing TAVR in the Gulf region, comorbidities that drive outcomes, procedural success, complications, and one-year outcomes of death or rehospitalization. METHODS: This is a retrospective cohort study for adult patients aged at least 18 years undergoing TAVR at eight centers in the Gulf region. The primary outcome was a composite of death or re-hospitalization at one-year. Secondary outcomes included the individual components of the composite, stroke, and myocardial infarction (MI). We used multivariable Cox regression to determine factors associated with the composite endpoint. RESULTS: A total of 795 patients (56% male) were included in the final analysis with a mean age of 74.6 (standard deviation (SD) 8.9) years, Society of Thoracic Surgeons Score (STS) Score 4.9 (4.2), ejection fraction of 53% (12.7%). Transfemoral approach was employed in over 95% (762/795). The primary outcomes rate was 12.8% (95% confidence interval [CI]: 10.6-15.4); secondary endpoints were death 5.4% (95% CI 4.0-7.2); stroke 0.8% (95% CI 0.3, 1.7), MI 0.8% (95% CI 0.4-1.9), rehospitalization: 9.3% (95% CI 7.5-11.5) of whom 71.6% were related to cardiovascular causes. 77% of the cardiovascular admissions were attributable to heart failure or the need for pacemaker implantation. Stage IV or V chronic kidney disease was significantly associated with the primary composite endpoint (Hazard Ratio: 2.49, [95% CI: 1.31, 4.73], p = 0.005). Although not significant, paravalvular leak and severe left ventricular dysfunction showed a 2-fold and 3-fold increased risk for the composite endpoint, respectively. CONCLUSIONS: The Gulf TAVR registry is the first of its kind in the region. It profiles an elderly population with a high procedural success rate and a low rate of complications. One-year outcomes were primarily driven by repeat hospitalization for heart failure and pacemaker implantation indicating a need to optimize heart failure management and improve algorithms for the detection of conduction abnormalities.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
10.
J Soc Cardiovasc Angiogr Interv ; 1(6): 100509, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-39132359

RESUMEN

Background: Several international registries have examined outcomes in women undergoing transcatheter aortic valve replacement (TAVR). However, none of these studies included women from the Gulf region. The Women IN Gulf Transcatheter Aortic Valve Replacement (WIN Gulf TAVR) registry aimed to examine sex-based differences in patient characteristics and outcomes in patients undergoing TAVR in the region. Methods: This registry is a prespecified subanalysis of the main Gulf TAVR registry. Baseline characteristics, procedural details and success, and 1-year outcomes were recorded. The primary outcome consisted of a composite of all causes of death, myocardial infarction (MI), and rehospitalizations at 1 year. The secondary outcomes were a composite of the individual components of the primary composite. Results: A total of 347 women (44% of the Gulf TAVR registry) were included in the final analysis, with a mean age of 74.1 ± 9.1 years; mean ejection fraction of 56.20% ± 10.52%; and mean Society of Thoracic Surgeons score of 5.30 ± 4.35. The composite primary end point occurred in 12.4% (95% CI, 9.3-16.2). The individual components of the primary end point were as follows: death, 4.3% (95% CI, 2.6-7.0); MI, 1.1% (95% CI, 0.4-2.9); and rehospitalization, 9.8% (95% CI, 7.1-13.3), with 7.2% (95% CI, 4.9-10.4) related to cardiac causes. Conclusions: Women in the WIN Gulf TAVR registry had outcomes and baseline characteristics similar to men. Although higher rehospitalizations for cardiac causes and MI at 1 year in women were noted, the overall survival was better in women. These observations warrant a larger cohort to identify the drivers of events.

11.
Case Rep Med ; 2021: 6676339, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34335787

RESUMEN

Cardiogenic shock (CS) associated with biventricular failure (BiVF) carries significant in-hospital morbidity and mortality. We describe here the successful use of percutaneous biventricular Impella (Bi-Pella) for cardiogenic shock secondary to acute biventricular myocardial infarctions (AMI-CS), as guided by parameters such as mixed venous oxygen saturation (SvO2), pulmonary artery pulsatility index (PAPi), central venous pressure (CVP), and cardiac power output (CPO). We aim to highlight the promising outcomes of timely implanted biventricular Impella in (AMI-CS).

12.
J Robot Surg ; 15(4): 529-538, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32776285

RESUMEN

Limited data exist regarding knowledge and perceptions of surgeons and patients about robotic-assisted surgery (RAS) in the Middle East. This study aimed to explore perceptions of surgeons and patients about RAS. A questionnaire-based survey was distributed among surgeons of different specialties and patients. Between March and September 2019, 278 and 256 surveys were completed by surgeons and patients, respectively (95.2% and 94.8% response rate, respectively). The surgeons' self-reported experience with technology was related to the level of comfort with computers and computer literacy. Most surgeons have heard of RAS availability, and the majority agreed to its introduction into the healthcare system. However, only 75 (27%) of the surgeons thought that the surgeon has complete control over the robot, and 69 (25%) surgeons were not sure of the level of control the surgeon has over the robot reflecting poor knowledge about this technology. Less than a third of patient respondents have heard of RAS. However, half of them would consider it should they need to undergo surgery. When compared to open surgery, 23 (9%), 26 (10%), and 94 (37%) patient respondents thought that RAS caused less pain, had fewer complications, and was faster than conventional surgery, respectively. Knowledge and perceptions about RAS are limited among surgeons and patients in Kuwait. Efforts should focus on increasing awareness.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Cirujanos , Estudios Transversales , Humanos , Percepción , Procedimientos Quirúrgicos Robotizados/métodos , Encuestas y Cuestionarios
13.
Cardiovasc Intervent Radiol ; 44(3): 376-383, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33388870

RESUMEN

PURPOSE: To determine whether low total psoas muscle area (tPMA), as a surrogate for sarcopaenia, is a predictor of adverse outcomes in patients undergoing advanced EVAR. MATERIALS AND METHODS: A retrospective review of medical records was performed for 257 patients who underwent advanced EVAR (fenestrated or branched technique) in a single tertiary centre from 1 January 2008 to 1 September 2019. The study cohort was divided into tertiles based on tPMA measurement performed independently by two observers from a peri-procedural CT scan at the level of mid-L3 vertebral body. The low tertile was considered sarcopaenic. Logistic regression analysis was used to assess the association of tPMA with 30-day mortality and post-procedural complications. Univariable analysis and adjusted multivariable Cox regression were used to assess the association of tPMA with all-cause mortality. RESULTS: A total of 257 patients comprised 193 males and 64 females with the mean age of 75.4 years (± 6.8) were included. Adjusted multivariable Cox regression revealed an 8% reduction in all-cause mortality for every 1 cm2 increase in tPMA, P < 0.05. TPMA was associated with 30-day mortality (OR 0.85, 95% CI 0.75-0.96, P < 0.05) and spinal cord ischaemia (SCI) (OR 0.89, 95% CI 0.82-0.97, P < 0.05). For remaining post-procedural complications, tPMA was not a useful predictive tool. TPMA correlated negatively with hospital stay length (rs-0.26, P < 0.001). Patients with lower tPMA were more likely to be discharged to a rehabilitation center (OR 0.93, 95% CI 0.87-0.98 , P < 0.05). CONCLUSION: Measurement of tPMA can be a useful predictive tool for adverse outcomes after advanced EVAR. LEVEL OF EVIDENCE: Level 3, Retrospective cohort study.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Músculos Psoas/diagnóstico por imagen , Músculos Psoas/fisiopatología , Sarcopenia/fisiopatología , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Sarcopenia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
14.
Eur J Case Rep Intern Med ; 7(11): 001854, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33194863

RESUMEN

Chest pain in a young postpartum female can have many causes; however, when associated with ST elevation on ECG, spontaneous coronary artery dissection (SCAD) should be high on the list. Coronary angiography remains the first step in delineating the coronary lesion in suspected cases of SCAD and optical coherence tomography (OCT) can be crucial when the angiographic appearance remains uncertain. We present a case of a young postpartum female with ST elevation myocardial infarction (STEMI). Coronary angiography revealed a dilated part of the middle segment of the left anterior descending (LAD) artery while intramural haematoma (IMH) of the coronary artery wall was found on OCT, which confirmed the clinically suspected diagnosis of SCAD. LEARNING POINTS: SCAD is a rare entity and considered the most common cause of STEMI in the postpartum state.OCT is an intracoronary imaging modality utilizing light waves for image acquisition with high resolution, assisting in clinical decision-making regarding the pathophysiological mechanism of an acute coronary syndrome (ACS).In suspected cases of SCAD, coronary angiography remains the first diagnostic line and OCT can be crucial in confirming an ambiguous angiographic appearance.

15.
Eur J Case Rep Intern Med ; 7(12): 001951, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33313007

RESUMEN

Patent foramen ovale is a risk factor for systemic embolic events such as cryptogenic stroke. Far less commonly, patent foramen ovale is associated with non-cerebral systemic embolic events. Paradoxical coronary artery embolism is a rare and underdiagnosed cause of acute myocardial infarction. It should be considered in patients presenting with myocardial infarction and an otherwise low-risk profile for atherosclerotic coronary artery disease. We describe a case of paradoxical coronary artery embolism causing ST elevation myocardial infarction. Echocardiography demonstrated patent foramen ovale with a significant shunt. In addition to the treatment of the acute coronary event, patent foramen ovale closure was performed to prevent recurrent paradoxical embolic events. LEARNING POINTS: Coronary artery embolism is an established cause of acute coronary syndrome, but paradoxical coronary artery embolism causing myocardial infarction is rare and requires a high degree of clinical suspicion for diagnosis.Recognition of this condition is important as it has an influence on management and prognosis. A search for venous thrombosis and underlying prothrombotic conditions should be undertaken.Percutaneous device closure of the patent foramen ovale should be considered to prevent future embolic events.

16.
Semin Ultrasound CT MR ; 41(2): 122-138, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32446427

RESUMEN

Imaging of primary hepatic neoplasms in patients at risk for hepatocellular carcinoma (HCC) and in patients with otherwise normal livers relies on proper multiphase image acquisition technique, with emphasis on a high-quality, late arterial phase, using either CT or MRI for accurate image interpretation. The introduction of liver imaging reporting and data system in 2011, with subsequent multiple updates, the most recent in 2018, has provided standardization of image interpretation, reporting and management recommendations for liver observations in patients at risk for HCC. This review article will emphasize key points of imaging primary liver tumors with emphasis on liver imaging reporting and data system, including strengths of this system. We will also review imaging of less common primary liver tumors such as cholangiocarcinoma and angiosarcomas. Imaging pitfall associated with primary liver malignancies will be demonstrated as well as ways to mitigate them. Finally, imaging and reporting of findings following locoregional treatment of HCC will be reviewed.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía/métodos , Diagnóstico Diferencial , Humanos , Hígado/diagnóstico por imagen , Hígado/cirugía
17.
Am J Cardiol ; 125(9): 1369-1377, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32098656

RESUMEN

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on pre-BAV was available for 1,262 patients (99.9%). Primary end points were pre-discharge moderate-to-severe paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation, and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n = 1,051) or without predilatation (n = 211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs 3.4%, p = 0.214; 30-day permanent pacemaker implantation 9.0% vs 8.0%, p = 0.660; 30-day death or stroke 4.9% vs 4.4%, p = 0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/instrumentación , Dilatación/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Humanos , Masculino , Periodo Preoperatorio , Sistema de Registros , Estudios Retrospectivos
18.
JACC Cardiovasc Interv ; 12(5): 433-443, 2019 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-30846081

RESUMEN

OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: In this multicenter registry, transfemoral TAVR with the NEO and PRO bioprostheses was associated with high device success, acceptable rates of paravalvular aortic regurgitation II+, and good 30-day clinical outcomes. After adjusting for potential confounders, short-term outcomes were similar between the devices.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Puntaje de Propensión , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
19.
JACC Cardiovasc Interv ; 11(17): 1696-1705, 2018 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-30190060

RESUMEN

OBJECTIVES: This study assessed the effect of overexpansion beyond labeled size (diameter) of transcatheter heart valves through an ex vivo bench study. BACKGROUND: Transcatheter heart valves function optimally when expanded to specific dimensions. However, clinicians may sometimes wish to overexpand balloon-expandable valves to address specific clinical challenges. The implications of overexpansion have assumed considerable importance, and objective information to guide practice is limited. METHODS: We evaluated SAPIEN 3 transcatheter heart valves (Edwards Lifesciences, Irvine, California). Valves (diameters of 23, 26, and 29 mm) were expanded to nominal dimensions, and then incrementally overexpanded with balloons sized 1-, 2-, and 3-mm larger than the recommended diameter. Valves underwent visual, microcomputed tomography, and hydrodynamic evaluation at various degrees of overexpansion. RESULTS: SAPIEN 3 valves with labeled diameters of 23, 26, and 29 mm could be incrementally overexpanded to midvalve diameters of 26.4, 28.4, and 31.2 mm, respectively. With overexpansion, there was visible restriction of the valve leaflets, which was particularly evident with the smaller valves. After maximal overexpansion of a 26-mm valve a leaflet tear was observed. High-speed video demonstrated impaired leaflet motion of both the 23- and 26-mm valves and hydrodynamic testing documented a regurgitant fraction for the 23- and 26-mm valves above accepted international standards. The maximally overexpanded 29-mm SAPIEN 3 still had relatively normal leaflet motion and excellent hydrodynamic function. Durability was not specifically evaluated. CONCLUSIONS: Overexpansion of balloon-expandable valves is possible. However, excessive overexpansion may be associated with impaired hydrodynamic function, acute leaflet failure, and reduced durability. Smaller valves may be at greater risk with overexpansion than larger valves. Overexpansion is best avoided unless clinical circumstances are compelling.


Asunto(s)
Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Valvuloplastia con Balón , Ensayo de Materiales , Diseño de Prótesis
20.
Saudi Med J ; 38(9): 942-947, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28889153

RESUMEN

OBJECTIVES: To determine medical residents' emotions, attitudes, and knowledge related to Middle East respiratory syndrome (MERS) outbreaks. Methods: In this is a cross sectional study, self-administered questionnaires were distributed and collected before resident education activities in 4 tertiary hospitals in Riyadh, Kingdom of Saudi Arabia, between November 2015 and January 2016. The questionnaire included questions related to residents' demographic data and their emotions, attitudes, and knowledge related to an MERS outbreak. Results: Of the 228 participants analyzed, 85.5% believed their work put them at risk of infection, and two-thirds believed their family was exposed to a greater risk of infection. However, only 2.6% would change their job. Nearly half of the residents indicated that their hospital had a clear plan, and only 28% considered themselves not well prepared for an MERS outbreak. Conclusions: Our study highlights medical residents' attitude and emotions related to MERS outbreaks. Residents' concerns and emotions in relation to MERS should be considered in greater detail by hospital policymakers.


Asunto(s)
Actitud del Personal de Salud , Infecciones por Coronavirus/epidemiología , Internado y Residencia , Estudios Transversales , Brotes de Enfermedades , Femenino , Humanos , Masculino , Arabia Saudita/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA