Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Opt Express ; 27(3): 3324-3336, 2019 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-30732355

RESUMEN

We report optical constants of e-beam evaporated yttrium oxide Y2O3 thin films as determined from angle-dependent reflectance measurements at wavelengths from 5 to 50 nm. Samples were measured using synchrotron radiation at the Advanced Light Source. The experimental reflectance data were fit to obtain values for the index of refraction and thin film roughness. We compare our computed constants with those of previous researchers and those computed using the independent atom approximation from the CXRO website. We found that the index of refraction near 36 nm is much lower than previous data from Tomiki as reported by Palik. The real part of the optical constants is about 10% to 15% below CXRO values for wavelengths between 17 nm and 30 nm. Films were also characterized chemically, structurally, and optically by ellipsometry and atomic force microscopy.

2.
Appl Opt ; 49(9): 1581-5, 2010 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-20300153

RESUMEN

We use a laser high-harmonics-based extreme-ultraviolet (EUV) polarimeter to determine the optical constants of elemental uranium in the wavelength range from 10 to 47 nm. The constants are extracted from the measured ratio of p-polarized to s-polarized reflectance from a thin uranium film deposited in situ. The film thickness is inferred from a spectroscopic ellipsometry measurement of the sample after complete oxidation in room air. Uranium has been used as a high-reflectance material in the EUV. However, difficulties with oxidation prevented its careful characterization previous to this study. We find that measured optical constants for uranium vary significantly from previous estimates.

3.
Opt Express ; 17(26): 23873-9, 2009 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-20052098

RESUMEN

We use laser high-order harmonics and a polarization-ratio-reflectance technique to determine the optical constants of copper and oxidized copper in the wavelength range 10-35 nm. This measurement resolves previously conflicting data sets, where disagreement on optical constants of copper in the extreme ultraviolet most likely arises from inadvertent oxidation of samples before measurement.


Asunto(s)
Cobre/química , Rayos Láser , Luz , Ensayo de Materiales , Refractometría , Dispersión de Radiación
4.
Rev Sci Instrum ; 79(10): 103108, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044703

RESUMEN

We describe an extreme-ultraviolet (EUV) polarimeter that employs laser-generated high-order harmonics as the light source. The polarimeter is designed to characterize materials and thin films for use with EUV light. Laser high harmonics are highly directional with easily rotatable linear polarization, not typically available with other EUV sources. The harmonics have good wavelength coverage, potentially spanning the entire EUV from a few to a hundred nanometers. Our instrument is configured to measure reflectances from 14 to 30 nm and has approximately 180 spectral resolution (lambda/Delta lambda). The reflection from a sample surface can be measured over a continuous range of incident angles (5 degrees-75 degrees). A secondary 14 cm gas cell attenuates the harmonics in a controlled way to keep signals within the linear dynamic range of the detector, comprised of a microchannel plate coupled to a phosphorous screen and charge coupled device camera. The harmonics are produced using approximately 10 mJ, approximately 35 fs, and approximately 800 nm laser pulses with a repetition rate of 10 Hz. Per-shot energy monitoring of the laser discriminates against fluctuations. The polarimeter reflectance data agree well with data obtained at the Advanced Light Source Synchrotron (Beamline 6.3.2).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA