Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 93(38): 12954-12965, 2021 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-34520166

RESUMEN

Surface-enhanced Raman scattering (SERS) probes offer considerable opportunities in label-based biosensing and analysis. However, achieving specific and reproducible performance, where low detection limits are needed in complex media, remains a challenge. Herein, we present a general strategy employing gold nanorod SERS probes and rationally designed surface chemistry involving protein resistant layers and antibodies to allow for the selective detection of species in complex media. By utilizing the ability of gold nanorods for selective surface modification, Raman reporters (4-mercaptobenzoic acid) were attached to the tips. Importantly, the sides of the nanorods were modified using a mixed layer of two different length stabilizing ligands (carboxyl-terminated oligo ethylene glycols) to ensure colloidal stability, while antibodies were attached to the stabilizing ligands. The nanoparticle interfacial design improves the colloidal stability, unlocks the capability of the probes for targeting biomolecules in complex matrices, and gives the probes the high SERS efficiency. The utility of this probe is demonstrated herein via the detection of Salmonella bacteria at the single bacterium level in complex food matrices using an anti-Salmonella IgG antibody-conjugated probe. The modular nature of the surface chemistry enables the SERS probes to be employed with a molecularly diverse range of biorecognition species (e.g., antibodies and peptides) for many different analytes, thus opening up new opportunities for efficient biosensing applications.


Asunto(s)
Nanopartículas del Metal , Nanotubos , Oro , Inmunoensayo , Inmunoglobulina G , Espectrometría Raman
2.
Analyst ; 144(21): 6225-6230, 2019 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-31555776

RESUMEN

Herein, a glucose meter-based immunosensing platform is developed that allows the quantification of procalcitonin (PCT) in whole blood samples. PCT is a biomarker for sepsis and its early detection would improve the safety of the patient, as the diagnostic process will be easier and faster. The method employs liposomes with encapsulated glucose as a signal generation tag, which are then used in a sandwich immunoassay by conjugating an antibody to the liposome. The optimal liposomes' size and concentration of encapsulated glucose is determined experimentally to be 200 nm and 27.8 mM, respectively. Upon the addition of a surfactant (Triton X-100), the glucose is released and a signal is detected with a personal glucose meter (PGM). This signal is directly proportional to the concentration of the PCT in the sample. The dynamic range of the assay developed was 0.153-15.38 nM, and could allow the detection of PCT as low as 0.15 nM. The assay showed a high selectivity toward PCT against other proteins such as C-reactive protein and human serum albumin and good reproducibility. This assay was able to quantitatively determine the amount of PCT in whole blood samples at clinically-relevant concentrations.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucosa/química , Inmunoensayo/instrumentación , Liposomas/química , Polipéptido alfa Relacionado con Calcitonina/sangre , Cápsulas , Humanos , Cinética , Límite de Detección
3.
Chem Commun (Camb) ; 57(20): 2559-2562, 2021 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-33586712

RESUMEN

The direct quantification of programmed death-ligand 1 (PD-L1) as a biomarker for cancer diagnosis, prognosis and treatment efficacy is an unmet clinical need. Herein, we demonstrate the first report of rapid, ultrasensitive and selective electrochemical detection of PD-L1 directly in undiluted whole blood using modified gold-coated magnetic nanoparticles as "dispersible electrodes" with an ultralow detection limit of 15 attomolar and a response time of only 15 minutes.


Asunto(s)
Antígeno B7-H1/sangre , Biomarcadores de Tumor/sangre , Anticuerpos/química , Técnicas Biosensibles , Técnicas Electroquímicas , Electrodos , Oro/química , Humanos , Límite de Detección , Nanopartículas Magnéticas de Óxido de Hierro/química , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA