Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pediatr Cardiol ; 42(6): 1284-1292, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33877418

RESUMEN

Normalizing cardiovascular measurements for body size allows for comparison among children of different ages and for distinguishing pathologic changes from normal physiologic growth. Because of growing interest to use height for normalization, the aim of this study was to develop height-based normalization models and compare them to body surface area (BSA)-based normalization for aortic and left ventricular (LV) measurements. The study population consisted of healthy, non-obese children between 2 and 18 years of age enrolled in the Pediatric Heart Network Echo Z-Score Project. The echocardiographic study parameters included proximal aortic diameters at 3 locations, LV end-diastolic volume, and LV mass. Using the statistical methodology described in the original project, Z-scores based on height and BSA were determined for the study parameters and tested for any clinically significant relationships with age, sex, race, ethnicity, and body mass index (BMI). Normalization models based on height versus BSA were compared among underweight, normal weight, and overweight (but not obese) children in the study population. Z-scores based on height and BSA were calculated for the 5 study parameters and revealed no clinically significant relationships with age, sex, race, and ethnicity. Normalization based on height resulted in lower Z-scores in the underweight group compared to the overweight group, whereas normalization based on BSA resulted in higher Z-scores in the underweight group compared to the overweight group. In other words, increasing BMI had an opposite effect on height-based Z-scores compared to BSA-based Z-scores. Allometric normalization based on height and BSA for aortic and LV sizes is feasible. However, height-based normalization results in higher cardiovascular Z-scores in heavier children, and BSA-based normalization results in higher cardiovascular Z-scores in lighter children. Further studies are needed to assess the performance of these approaches in obese children with or without cardiac disease.


Asunto(s)
Estatura , Superficie Corporal , Enfermedades Cardiovasculares/diagnóstico , Corazón/anatomía & histología , Adolescente , Enfermedades Cardiovasculares/diagnóstico por imagen , Niño , Preescolar , Bases de Datos Factuales , Ecocardiografía , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Obesidad Infantil/epidemiología , Pediatría , Valores de Referencia
2.
Cardiol Young ; 30(4): 456-461, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32180543

RESUMEN

BACKGROUND: The Pediatric Heart Network Normal Echocardiogram Database Study had unanticipated challenges. We sought to describe these challenges and lessons learned to improve the design of future studies. METHODS: Challenges were divided into three categories: enrolment, echocardiographic imaging, and protocol violations. Memoranda, Core Lab reports, and adjudication logs were reviewed. A centre-level questionnaire provided information regarding local processes for data collection. Descriptive statistics were used, and chi-square tests determined differences in imaging quality. RESULTS: For the 19 participating centres, challenges with enrolment included variations in Institutional Review Board definitions of "retrospective" eligibility, overestimation of non-White participants, centre categorisation of Hispanic participants that differed from National Institutes of Health definitions, and exclusion of potential participants due to missing demographic data. Institutional Review Board amendments resolved many of these challenges. There was an unanticipated burden imposed on centres due to high numbers of echocardiograms that were reviewed but failed to meet submission criteria. Additionally, image transfer software malfunctions delayed Core Lab image review and feedback. Between the early and late study periods, the proportion of unacceptable echocardiograms submitted to the Core Lab decreased (14 versus 7%, p < 0.01). Most protocol violations were from eligibility violations and inadvertent protected health information disclosure (overall 2.5%). Adjudication committee reviews led to protocol changes. CONCLUSIONS: Numerous challenges encountered during the Normal Echocardiogram Database Study prolonged study enrolment. The retrospective design and flaws in image transfer software were key impediments to study completion and should be considered when designing future studies collecting echocardiographic images as a primary outcome.


Asunto(s)
Ecocardiografía/estadística & datos numéricos , Cardiopatías Congénitas/diagnóstico , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Encuestas y Cuestionarios
3.
Cardiol Young ; 29(10): 1248-1256, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31477187

RESUMEN

BACKGROUND: While echocardiographic parameters are used to quantify ventricular function in infants with single ventricle physiology, there are few data comparing these to invasive measurements. This study correlates echocardiographic measures of diastolic function with ventricular end-diastolic pressure in infants with single ventricle physiology prior to superior cavopulmonary anastomosis. METHODS: Data from 173 patients enrolled in the Pediatric Heart Network Infant Single Ventricle enalapril trial were analysed. Those with mixed ventricular types (n = 17) and one outlier (end-diastolic pressure = 32 mmHg) were excluded from the analysis, leaving a total sample size of 155 patients. Echocardiographic measurements were correlated to end-diastolic pressure using Spearman's test. RESULTS: Median age at echocardiogram was 4.6 (range 2.5-7.4) months. Median ventricular end-diastolic pressure was 7 (range 3-19) mmHg. Median time difference between the echocardiogram and catheterisation was 0 days (range -35 to 59 days). Examining the entire cohort of 155 patients, no echocardiographic diastolic function variable correlated with ventricular end-diastolic pressure. When the analysis was limited to the 86 patients who had similar sedation for both studies, the systolic:diastolic duration ratio had a significant but weak negative correlation with end-diastolic pressure (r = -0.3, p = 0.004). The remaining echocardiographic variables did not correlate with ventricular end-diastolic pressure. CONCLUSION: In this cohort of infants with single ventricle physiology prior to superior cavopulmonary anastomosis, most conventional echocardiographic measures of diastolic function did not correlate with ventricular end-diastolic pressure at cardiac catheterisation. These limitations should be factored into the interpretation of quantitative echo data in this patient population.


Asunto(s)
Cateterismo Cardíaco/métodos , Ecocardiografía Doppler/métodos , Enalapril/uso terapéutico , Cardiopatías Congénitas/diagnóstico , Ventrículos Cardíacos/anomalías , Función Ventricular Izquierda/fisiología , Presión Ventricular/fisiología , Antihipertensivos/uso terapéutico , Diástole , Método Doble Ciego , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/tratamiento farmacológico , Cardiopatías Congénitas/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos
4.
Cardiol Young ; 27(7): 1265-1270, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28183375

RESUMEN

BACKGROUND: A few studies have evaluated the impact of clinical trial results on practice in paediatric cardiology. The Infant Single Ventricle (ISV) Trial results published in 2010 did not support routine use of the angiotensin-converting enzyme inhibitor enalapril in infants with single-ventricle physiology. We sought to assess the influence of these findings on clinical practice. METHODS: A web-based survey was distributed via e-mail to over 2000 paediatric cardiologists, intensivists, cardiothoracic surgeons, and cardiac advance practice nurses during three distribution periods. The results were analysed using McNemar's test for paired data and Fisher's exact test. RESULTS: The response rate was 31.5% (69% cardiologists and 65% with >10 years of experience). Among respondents familiar with trial results, 74% reported current practice consistent with trial findings versus 48% before trial publication (p<0.001); 19% used angiotensin-converting enzyme inhibitor in this population "almost always" versus 36% in the past (p<0.001), and 72% reported a change in management or improved confidence in treatment decisions involving this therapy based on the trial results. Respondents familiar with trial results (78%) were marginally more likely to practise consistent with the trial results than those unfamiliar (74 versus 67%, p=0.16). Among all respondents, 28% reported less frequent use of angiotensin-converting enzyme inhibitor over the last 3 years. CONCLUSIONS: Within 5 years of publication, the majority of respondents was familiar with the Infant Single Ventricle Trial results and reported less frequent use of angiotensin-converting enzyme inhibitor in single-ventricle infants; however, 28% reported not adjusting their clinical decisions based on the trial's findings.


Asunto(s)
Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Cardiólogos , Enalapril/uso terapéutico , Cardiopatías Congénitas/tratamiento farmacológico , Ventrículos Cardíacos/anomalías , Pautas de la Práctica en Medicina , Ensayos Clínicos como Asunto , Correo Electrónico , Cardiopatías Congénitas/fisiopatología , Insuficiencia Cardíaca/epidemiología , Humanos , Pediatría , Encuestas y Cuestionarios , Investigación Biomédica Traslacional , Estados Unidos
5.
Pediatr Cardiol ; 35(4): 658-67, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24265000

RESUMEN

M-mode and 2-dimensional (2D) echocardiographic imaging are routinely used to quantify left-ventricular (LV) size and function in pediatric patients with dilated cardiomyopathy (DCM). The reproducibility of and correlation between these techniques are unknown. This analysis sought to compare interreader, intrareader, and interacquisition reproducibility of M-mode versus 2D measurements in pediatric DCM patients. The Ventricular Volume Variability study of the Pediatric Heart Network is a multicenter, prospective, observational study assessing the course of chronic DCM in children. Two sonographers performed baseline image acquisitions locally, and two readers performed measurements at the echocardiographic core laboratory. One reader repeated measurements 1 month later. These data were used to assess reproducibility and agreement between M-mode and 2D measurements. One hundred sixty-nine subjects were enrolled. M-mode had similar or greater reproducibility in both intrareader and interreader settings for LV dimensions, shortening fraction (SF), and most wall thicknesses. In contrast, 2D reproducibility was similar or better for nearly all variables in the interacquisition setting but not for SF. Interacquisition variability was approximately twice the intrareader variability. LV dimensions by either modality consistently had high reproducibility and had the highest agreement between modalities. In pediatric DCM patients, variability of linear echocardiographic assessment could be minimized by relying on a single reader and using a consistent method (M-mode or 2D) for serial measurements, preferably M-mode when SF is the primary variable of interest. Except for LV dimensions, M-mode and 2D values should not be used interchangeably due to poor agreement.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Adolescente , Cardiomiopatía Dilatada/fisiopatología , Niño , Preescolar , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Curva ROC , Reproducibilidad de los Resultados , Adulto Joven
6.
Circulation ; 122(4): 333-40, 2010 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-20625111

RESUMEN

BACKGROUND: Angiotensin-converting enzyme inhibitor therapy improves clinical outcome and ventricular function in adults with heart failure. Infants with single-ventricle physiology have poor growth and are at risk for abnormalities in ventricular systolic and diastolic function. The ability of angiotensin-converting enzyme inhibitor therapy to preserve ventricular function and improve somatic growth and outcomes in these infants is unknown. METHODS AND RESULTS: The Pediatric Heart Network conducted a double-blind trial involving 230 infants with single-ventricle physiology randomized to receive enalapril (target dose 0.4 mg . kg(-1) . d(-1)) or placebo who were followed up until 14 months of age. The primary end point was weight-for-age z score at 14 months. The primary analysis was intention to treat. A total of 185 infants completed the study. There were 24 and 21 withdrawals or deaths in the enalapril and placebo groups, respectively (P=0.74). Weight-for-age z score was not different between the enalapril and placebo groups (mean+/-SE -0.62+/-0.13 versus -0.42+/-0.13, P=0.28). There were no significant group differences in height-for-age z score, Ross heart failure class, brain natriuretic peptide concentration, Bayley scores of infant development, or ventricular ejection fraction. The incidence of death or transplantation was 13% and did not differ between groups. Serious adverse events occurred in 88 patients in the enalapril group and 87 in the placebo group. CONCLUSIONS: Administration of enalapril to infants with single-ventricle physiology in the first year of life did not improve somatic growth, ventricular function, or heart failure severity. The results of this randomized trial do not support the routine use of enalapril in this population.


Asunto(s)
Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Enalapril/uso terapéutico , Insuficiencia Cardíaca/epidemiología , Ventrículos Cardíacos/anomalías , Aldosterona/sangre , Antihipertensivos/efectos adversos , Antihipertensivos/uso terapéutico , Método Doble Ciego , Enalapril/efectos adversos , Endotelio Vascular/fisiopatología , Tasa de Filtración Glomerular/fisiología , Humanos , Lactante , Volumen Sistólico
7.
J Pediatr ; 159(6): 1017-22.e2, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21784436

RESUMEN

OBJECTIVES: To describe growth patterns in infants with single ventricle physiology and determine factors influencing growth. STUDY DESIGN: Data from 230 subjects enrolled in the Pediatric Heart Network Infant Single Ventricle Enalapril Trial were used to assess factors influencing change in weight-for-age z-score (z) from study enrollment (0.7 ± 0.4 months) to pre-superior cavopulmonary connection (SCPC; 5.1 ± 1.8 months, period 1) and pre-SCPC to final study visit (14.1 ± 0.9 months, period 2). Predictor variables included patient characteristics, feeding regimen, clinical center, and medical factors during neonatal (period 1) and SCPC hospitalizations (period 2). Univariate regression analysis was performed, followed by backward stepwise regression and bootstrapping reliability to inform a final multivariable model. RESULTS: Weights were available for 197 of 230 subjects for period 1 and 173 of 197 subjects for period 2. For period 1, greater gestational age, younger age at study enrollment, tube feeding at neonatal hospitalization discharge, and clinical center were associated with a greater negative z (poorer growth) in multivariable modeling (adjusted R(2) = 0.39, P < .001). For period 2, younger age at SCPC and greater daily caloric intake were associated with greater positive z (better growth; R(2) = 0.10, P = .002). CONCLUSIONS: Aggressive nutritional support and earlier SCPC are modifiable factors associated with a favorable change in weight-for-age z-score.


Asunto(s)
Trastornos del Crecimiento/etiología , Cardiopatías Congénitas/complicaciones , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Enalapril/uso terapéutico , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos
8.
Int J Cardiol ; 307: 31-35, 2020 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-31668657

RESUMEN

BACKGROUND: Longitudinal clinical surveillance by transthoracic echocardiography (TTE) is an established practice in children with repaired tetralogy of Fallot (TOF). Non-Invasive Imaging Guidelines recommends a list of reporting elements that should be addressed during routine TTE in this population. In this study, we assessed the adherence to these recommendations. METHODS: This was a multi-center (n = 8) retrospective review of TTE reports in children ≤11 years of age who have had complete TOF repair. We included 10 patients from each participating center (n = 80) and scored 2 outpatient follow-up TTE reports on each patient. The adherence rate was based on completeness of TTE reporting elements derived from the guidelines. RESULTS: We reviewed 160 TTE reports on 80 patients. Median age was 4.4 months (IQR 1.5-6.6) and 3.6 years (IQR 1.3-6.4) at the time of complete surgical repair and first TTE report, respectively. The median adherence rate to recommended reporting elements was 61% (IQR 53-70). Of the 160 reports, 9 (7%) were ≥80% adherent and 40 (25%) were ≥70% adherent. Quantitative measurements of right ventricular outflow tract (RVOT), right ventricular (RV) size and function, and branch pulmonary arteries were least likely to be reported. CONCLUSIONS: Overall adherence to the most recent published imaging guidelines for surveillance of children with repaired TOF patients was suboptimal, especially for reporting of RVOT, RV size and function, and branch pulmonary arteries. Further studies are needed to explore the barriers to adherence to guidelines and most importantly, whether adherence is associated with clinical outcomes.


Asunto(s)
Tetralogía de Fallot , Niño , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Lactante , Arteria Pulmonar , Estudios Retrospectivos , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Resultado del Tratamiento
9.
J Am Soc Echocardiogr ; 32(10): 1331-1338.e1, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31351792

RESUMEN

BACKGROUND: The reliability of left ventricular (LV) systolic functional indices calculated from blinded echocardiographic measurements of LV size has not been tested in a large cohort of healthy children. The objective of this study was to estimate interobserver variability in standard measurements of LV size and systolic function in children with normal cardiac anatomy and qualitatively normal function. METHODS: The Pediatric Heart Network Normal Echocardiogram Database collected normal echocardiograms from healthy children ≤18 years old distributed equally by age, gender, and race. A core lab used two-dimensional echocardiograms to measure LV dimensions from which a separate data coordinating center calculated LV volumes and systolic functional indices. To evaluate interobserver variability, two independent expert pediatric echocardiographic observers remeasured LV dimensions on a subset of studies, while blinded to calculated volumes and functional indices. RESULTS: Of 3,215 subjects with measurable images, 552 (17%) had a calculated LV shortening fraction (SF) < 25% and/or LV ejection fraction (EF) < 50%; the subjects were significantly younger and smaller than those with normal values. When the core lab and independent observer measurements were compared, individual LV size parameter intraclass correlation coefficients were high (0.81-0.99), indicating high reproducibility. The intraclass correlation coefficients were lower for SF (0.24) and EF (0.56). Comparing reviewers, 40/56 (71%) of those with an abnormal SF and 36/104 (35%) of those with a normal SF based on core lab measurements were calculated as abnormal from at least one independent observer. In contrast, an abnormal EF was less commonly calculated from the independent observers' repeat measures; only 9/47 (19%) of those with an abnormal EF and 8/113 (7%) of those with a normal EF based on core lab measurements were calculated as abnormal by at least one independent observer. CONCLUSIONS: Although blinded measurements of LV size show good reproducibility in healthy children, subsequently calculated LV functional indices reveal significant variability despite qualitatively normal systolic function. This suggests that, in clinical practice, abnormal SF/EF values may result in repeat measures of LV size to match the subjective assessment of function. Abnormal LV functional indices were more prevalent in younger, smaller children.


Asunto(s)
Ecocardiografía , Función Ventricular Izquierda , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Sístole , Wisconsin
10.
Circ Cardiovasc Imaging ; 10(11)2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29133477

RESUMEN

BACKGROUND: Multiple echocardiographic methods are used to measure left ventricular size and function. Clinical management is based on individual evaluations and longitudinal trends. The Pediatric Heart Network VVV study (Ventricular Volume Variability) in pediatric patients with dilated cardiomyopathy has reported reproducibility of several of these measures, and how disease state and number of beats impact their reproducibility. In this study, we investigated the impact of observer and sonographer variation on reproducibility of dimension, area, and volume methods to determine the best method for both individual and sequential evaluations. METHODS AND RESULTS: In 8 centers, echocardiograms were obtained on 169 patients prospectively. During the same visit, 2 different sonographers acquired the same imaging protocol on each patient. Each acquisition was analyzed by 2 different observers; first observer analyzed the first acquisition twice. Intraobserver, interobserver, interacquisition, and interobserver-acquisition (different observers and different acquisition) reproducibility were assessed on measurements of left ventricular end-diastolic dimension, area, and volume. Left ventricular shortening fraction, ejection fraction, mass, and fractional area change were calculated. Percent difference was calculated as (interobservation difference/mean)×100. Interobserver reproducibility for both acquisitions was better for both volume and dimension measurements (P≤0.002) compared with area measurements, whereas intraobserver, interacquisition (for both observers), and interobserver-acquisition reproducibilities (for both observer-acquisition sets) were best for volume measurements (P≤0.01). Overall, interobserver-acquisition percent differences were significantly higher than interobserver and interacquisition percent differences (P<0.001). CONCLUSIONS: In pediatric patients with dilated cardiomyopathy, compared with dimension and area methods, left ventricular measurements by volume method have the best reproducibility in settings where assessment is not performed by the same personnel. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00123071.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Adolescente , Factores de Edad , Cardiomiopatía Dilatada/fisiopatología , Niño , Preescolar , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Contracción Miocárdica , Variaciones Dependientes del Observador , Ontario , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Volumen Sistólico , Estados Unidos , Función Ventricular Izquierda , Adulto Joven
11.
J Am Soc Echocardiogr ; 30(7): 699-707.e1, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28501374

RESUMEN

BACKGROUND: Infants with single ventricular physiology have volume and pressure overload that adversely affect ventricular mechanics. The impact of superior cavopulmonary anastomosis (SCPA) on single left ventricles versus single right ventricles is not known. METHODS: As part of the Pediatric Heart Network placebo-controlled trial of enalapril in infants with single ventricular physiology, echocardiograms were obtained before SCPA and at 14 months and analyzed in a core laboratory. Retrospective analysis of the following measurements included single ventricular end-diastolic volume (EDV), end-systolic volume (ESV), mass, mass-to-volume ratio (mass/volume), and ejection fraction. Qualitative assessment of atrioventricular valve regurgitation and assessment of diastolic function were also performed. RESULTS: A total of 156 participants underwent echocardiography at both time points. Before SCPA, mean ESV and mass Z scores were elevated (3.4 ± 3.7 and 4.2 ± 2.9, respectively) as were mean EDV and mass/volume Z scores (2.1 ± 2.5 and 2.0 ± 2.9, respectively). EDV, ESV, and mass decreased after SCPA, but mass/volume and the degree of atrioventricular valve regurgitation did not change. Subjects with morphologic left ventricles demonstrated greater reductions in ventricular volumes and mass than those with right ventricles (mean change in Z score: left ventricular [LV] EDV, -1.9 ± 2.1; right ventricular EDV, -0.7 ± 2.5; LV ESV, -2.3 ± 2.9; right ventricular ESV, -0.9 ± 4.6; LV mass, -2.5 ± 2.8; right ventricular mass, -1.3 ± 2.6; P ≤ .03 for all). Approximately one third of patients whose diastolic function could be assessed had abnormalities at each time point. CONCLUSIONS: Decreases in ventricular size and mass occur in patients with single ventricle after SCPA, and the effect is greater in those with LV morphology. The remodeling process resulted in commensurate changes in ventricular mass and volume such that the mass/volume did not change significantly in response to the volume-unloading surgery.


Asunto(s)
Ecocardiografía Doppler/métodos , Puente Cardíaco Derecho/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Remodelación Ventricular/fisiología , Femenino , Humanos , Lactante , Masculino , América del Norte
12.
J Appl Physiol (1985) ; 120(11): 1301-18, 2016 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-26940654

RESUMEN

Systolic and diastolic function affect dilated cardiomyopathy (DCM) outcomes. However, systolic-diastolic coupling, as a distinct characteristic, may itself affect function but is poorly characterized. We hypothesized that echocardiographic left ventricular (LV) longitudinal systolic tissue velocities (S') correlate with diastolic longitudinal velocities (E') and that their relationship is associated with ventricular function and that this relationship is impaired in pediatric DCM. We analyzed data from the Pediatric Heart Network Ventricular Volume Variability study, using linear regression and generalized additive modeling to assess relationships between S' and E' at the lateral and septal mitral annulus. We explored relationships between the systolic:diastolic (S:D) coupling ratio (S':E' relative to age) and ventricular function. Up to 4 echocardiograms from 130 DCM patients (mean age: 9.3 ± 6.1 yr) and 1 echocardiogram from each of 591 healthy controls were analyzed. S' and E' were linearly related in controls (r = 0.64, P < 0.001) and DCM (r = 0.83, P < 0.001). In DCM, the magnitude of association between S' and E' was reduced with progressive ventricular remodeling. The S:D ratio was more strongly associated with LV function in controls vs. DCM. The septal S:D ratio was higher (presumed worse) in DCM vs. controls (0.69 ± 0.13 vs. 0.62 ± 0.12, P = 0.001). A higher septal S:D ratio was associated with worse LV dimensions (parameter estimate: 0.0061, P = 0.004), mass (parameter estimate: 0.0074, P = 0.002), ejection fraction (parameter estimate: -0.0303, P = 0.024), and inflow propagation (parameter estimate: -0.3538, P < .001). S:D coupling becomes weaker in DCM with LV remodeling and dysfunction. The S:D coupling ratio may be useful to assess coupling, warranting study in relation to patient outcomes.


Asunto(s)
Cardiomiopatía Dilatada/fisiopatología , Diástole/fisiología , Ventrículos Cardíacos/patología , Sístole/fisiología , Función Ventricular Izquierda/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Niño , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/fisiopatología
13.
J Thorac Cardiovasc Surg ; 130(2): 282-6, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16077388

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the outcome and risk factors for implant failure in pediatric patients who underwent pulmonary position homograft placement for right ventricular outflow tract obstruction compared with conduit placement as a component of the Ross operation. Actuarial 5-year survivals for cryopreserved right ventricle-to-pulmonary artery homografts range from 55% to 94% at all ages. It is not known whether there is a difference in homograft durability when utilized for right ventricular outflow tract obstruction or as part of the Ross operation. METHODS: The records of all pediatric patients receiving a right ventricle-to-pulmonary artery homograft from July 1989 through October 2003 were reviewed. Ninety-eight consecutive patients were studied (26 Ross, 72 non-Ross). In addition to Ross versus non-Ross comparisons, other potential risk factors for homograft failure analyzed included age at operation, follow-up time, type of surgery, and homograft type and size. RESULTS: Ross and non-Ross patients were comparable in age at the time of the operation and follow-up time. Homograft failure rates were 12% and 51% for Ross and non-Ross patients, respectively. Freedom from reintervention was 93% in the Ross and 66% in the non-Ross group at 5 years (P = .019). On multivariate analysis, non-Ross operation and age less than 2 years were significant predictors of homograft failure. CONCLUSIONS: 1. Pediatric patients undergoing the Ross operation have longer homograft survival than pediatric patients treated for right ventricular outflow tract obstruction, independent of age. 2. Homografts placed in patients less than 2 years of age have shorter homograft survival.


Asunto(s)
Implantación de Prótesis Vascular/efectos adversos , Oclusión de Injerto Vascular/etiología , Supervivencia de Injerto , Obstrucción del Flujo Ventricular Externo/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Falla de Prótesis , Factores de Riesgo , Resultado del Tratamiento
14.
Ann N Y Acad Sci ; 1054: 358-72, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16339684

RESUMEN

To examine the relationship between myocardial storage iron and body iron burden, as assessed by hepatic storage iron measurements, we studied 22 patients with transfusion-dependent thalassemia syndromes, all being treated with subcutaneous deferoxamine, and 6 healthy subjects. Study participants were examined with a Philips 1.5-T Intera scanner using three multiecho spin echo sequences with electrocardiographic triggering and respiratory navigator gating. Myocardial and hepatic storage iron concentrations were determined using a new magnetic resonance method that estimates total tissue iron stores by separately measuring the two principal forms of storage iron, ferritin and hemosiderin. In a subset of 10 patients with beta-thalassemia major, the hepatic storage iron concentration had been monitored repeatedly for 12-14 years by chemical analysis of tissue obtained by liver biopsy and by magnetic susceptometry. In this subset, we examine the relationship between hepatic iron concentration over time and our current magnetic resonance estimates of myocardial iron stores. No significant relationship was found between simultaneous estimates of myocardial and hepatic storage iron concentrations. By contrast, in the subset of 10 patients with beta-thalassemia major, the correlation between the 5-year average of hepatic iron concentration and the current myocardial storage iron was significant (R = .67, P = .03). In these patients, myocardial storage iron concentrations seem to reflect the control of body iron over a period of years. Magnetic resonance methods promise to provide more effective monitoring of iron deposition in vulnerable tissues, including the liver, heart, and endocrine organs, and could contribute to the development of iron-chelating regimens that more effectively prevent iron toxicity.


Asunto(s)
Sobrecarga de Hierro/metabolismo , Hierro/análisis , Hígado/química , Imagen por Resonancia Magnética/métodos , Miocardio/química , Talasemia beta/metabolismo , Adulto , Terapia por Quelación , Terapia Combinada , Deferoxamina/uso terapéutico , Femenino , Ferritinas/análisis , Hemoglobina E , Hemosiderina/análisis , Humanos , Quelantes del Hierro/uso terapéutico , Sobrecarga de Hierro/etiología , Sobrecarga de Hierro/patología , Hígado/patología , Masculino , Persona de Mediana Edad , Modelos Biológicos , Miocardio/patología , Reacción a la Transfusión , Talasemia beta/complicaciones , Talasemia beta/tratamiento farmacológico , Talasemia beta/patología , Talasemia beta/terapia
15.
J Am Soc Echocardiogr ; 28(5): 549-558.e1, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25728351

RESUMEN

BACKGROUND: Several quantification algorithms for measuring left ventricular (LV) size and function are used in clinical and research settings. The aims of this study were to investigate the effects of measurement algorithm and beat averaging on the reproducibility of measurements of the left ventricle and to assess the magnitude of agreement among the algorithms in children with dilated cardiomyopathy. METHODS: Echocardiograms were obtained in 169 children from eight clinical centers. Inter- and intrareader reproducibility was assessed on measurements of LV volumes using the biplane Simpson, modified Simpson, and 5/6 × area × length (5/6AL) algorithms. Percentage error was calculated as inter- or intrareader difference/mean × 100. Single-beat measurements and the three-beat average (3BA) were compared. Intraclass correlation coefficients were calculated to assess agreement. RESULTS: Single-beat interreader reproducibility was lowest (percentage error was highest) using biplane Simpson; 5/6AL and modified Simpson were similar but significantly better than biplane Simpson (P < .05). Single-beat intrareader reproducibility was highest using 5/6AL (P < .05). The 3BA improved reproducibility for almost all measures (P < .05). Reproducibility in both single-beat and 3BA values fell with greater LV dilation and systolic dysfunction (P < .05). Intraclass correlation coefficients were >0.95 across measures, although absolute volume and mass values were systematically lower for biplane Simpson compared with modified Simpson and 5/6AL. CONCLUSIONS: The reproducibility of LV size and functional measurements in children with dilated cardiomyopathy is highest using the 5/6AL algorithm and can be further improved by using the 3BA. However, values derived from different algorithms are not interchangeable.


Asunto(s)
Algoritmos , Cardiomiopatía Dilatada/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Adolescente , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/fisiopatología , Niño , Preescolar , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Reproducibilidad de los Resultados , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
16.
J Thorac Cardiovasc Surg ; 127(4): 990-8; discussion 998-9, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15052195

RESUMEN

OBJECTIVES: We evaluated the early and medium-term single-center results for primary repair of Ebstein anomaly in both adults and children. METHODS: The records were reviewed of patients undergoing repair of Ebstein anomaly at the Children's Hospital of New York from September 1990 to September 2002. Functional, demographic, and echocardiographic parameters were studied both preoperatively and postoperatively, along with functional status and adverse events. The repair technique involved vertical plication of the atrialized ventricle and valve leaflet reimplantation after clockwise rotation. RESULTS: A total of 25 patients (19 children and 6 adults) underwent repair. The average age was 14.2 +/- 15.9 years, and the average follow-up was 4.1 +/- 3.4 years. Three patients required reoperation for right ventricular overload (1 child) and progressive, severe tricuspid regurgitation (2 adults); both adults received tricuspid valve replacements, one at 4 years and the other at 8 years post-repair. Three patients had radiofrequency ablation procedures performed intraoperatively. Ten patients (40%) had moderate-to-severe tricuspid regurgitation perioperatively. However, 18 children (95%) and 5 adults (83%) demonstrated significant improvement in exercise capacity late postoperatively. Two children died suddenly 11 months and 4 years after repair. DISCUSSION: Ebstein repair has good functional outcomes in children despite residual tricuspid regurgitation, likely because of reduction in right ventricular volume loading and relative annular and ventricular plasticity. Adult patients did not demonstrate the same durability of valve repair and frequently required tricuspid valve replacement. Intraoperative radiofrequency ablation represents an important adjunctive treatment for intractable arrhythmias, which may now represent relative indications for operative intervention.


Asunto(s)
Anomalía de Ebstein/cirugía , Adolescente , Adulto , Niño , Preescolar , Anomalía de Ebstein/diagnóstico por imagen , Ecocardiografía , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Humanos , Lactante , Masculino , Persona de Mediana Edad , New York , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Reoperación , Índice de Severidad de la Enfermedad , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Función Ventricular/fisiología
17.
J Am Soc Echocardiogr ; 17(10): 1066-72, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15452473

RESUMEN

Left ventricular ejection is depressed immediately after repair of ventricular septal defect (VSD). Postrepair functional depression seen after VSD closure could result from a reduction in preload. However, other mechanisms could be at work. Functional depression could also be caused by closure of a low-impedance path for left ventricular ejection, the introduction of a stiff akinetic patch, or the operation itself. We reasoned that functional depression mediated by changes in preload or afterload should symmetrically affect end-diastole and end-systole, whereas depression resulting from changes in septal mechanics should be localized. We, therefore, performed segmental wall-motion analysis on intraoperative echocardiograms from patients undergoing VSD and atrial septal defect repair. After VSD closure, there was an asymmetric change in left ventricular end-systolic segment length and a decrease in fractional segment shortening localized to the septal and lateral walls, whereas patients with atrial septal defect had a symmetric increase in fractional shortening. These results suggest that acute functional depression after VSD repair is a result of localized impairment of septal function.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Defectos del Tabique Interatrial/cirugía , Defectos del Tabique Interventricular/cirugía , Obstrucción del Flujo Ventricular Externo/etiología , Niño , Preescolar , Ecocardiografía Transesofágica , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interventricular/diagnóstico por imagen , Humanos , Lactante , Cuidados Intraoperatorios , Monitoreo Fisiológico , Complicaciones Posoperatorias/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda
18.
Circ Heart Fail ; 6(6): 1214-22, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24132734

RESUMEN

BACKGROUND: Despite medical advances, children with dilated cardiomyopathy (DCM) remain at high risk of death or need for cardiac transplantation. We sought to identify predictors of disease progression in pediatric DCM. METHODS AND RESULTS: The Pediatric Heart Network evaluated chronic DCM patients with prospective echocardiographic and clinical data collection during an 18-month follow-up. Inclusion criteria were age <22 years and DCM disease duration >2 months. Patients requiring intravenous inotropic/mechanical support or listed status 1A/1B for transplant were excluded. Disease progression was defined as an increase in transplant listing status, hospitalization for heart failure, intravenous inotropes, mechanical support, or death. Predictors of disease progression were identified using Cox proportional hazards modeling and classification and regression tree analysis. Of the 127 patients, 28 (22%) had disease progression during the 18-month follow-up. Multivariable analysis identified older age at diagnosis (hazard ratio=1.14 per year; P<0.001), larger left ventricular (LV) end-diastolic M-mode dimension z-score (hazard ratio=1.49; P<0.001), and lower septal peak systolic tissue Doppler velocity z-score (hazard ratio=0.81; P=0.01) as independent predictors of disease progression. Classification and regression tree analysis stratified patients at risk of disease progression with 89% sensitivity and 94% specificity based on LV end-diastolic M-mode dimension z-score ≥7.7, LV ejection fraction <39%, LV inflow propagation velocity (color M-mode) z-score <-0.28, and age at diagnosis ≥8.5 months. CONCLUSIONS: In children with chronic stable DCM, a combination of diagnosis after late infancy and echocardiographic parameters of larger LV size and systolic and diastolic function predicted disease progression. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00123071.


Asunto(s)
Cardiomiopatía Dilatada/fisiopatología , Trasplante de Corazón , Ventrículos Cardíacos/fisiopatología , Función Ventricular Izquierda/fisiología , Adolescente , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/cirugía , Niño , Preescolar , Progresión de la Enfermedad , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Lactante , Masculino , Pronóstico , Estudios Prospectivos , Factores de Tiempo
19.
J Am Soc Echocardiogr ; 25(8): 842-854.e6, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22677278

RESUMEN

BACKGROUND: Clinical trials often rely on echocardiographic measures of left ventricular size and function as surrogate end points. However, the quantitative impact of factors that affect the reproducibility of these measures is unknown. To address this issue, the National Heart, Lung, and Blood Institute-funded Pediatric Heart Network designed a longitudinal observational study of children with known or suspected dilated cardiomyopathy aged 0 to 22 years from eight pediatric clinical centers. METHODS: Clinical data were collected together with 150 echocardiographic indices of left ventricular size and function. Separate observers performed duplicate echocardiographic imaging. Multiple observers performed measurements from three cardiac cycles to enable assessment of intraobserver and interobserver variability. The impacts of beat averaging (BA), observer type (local vs core), and variable type (areas, calculations, dimensions, slopes, time intervals, and velocities) on measurement reproducibility were studied. The outcome measure was percentage error (100 × difference/mean). RESULTS: Of 173 enrolled subjects, 131 met criteria for dilated cardiomyopathy. BA, variable type and observer type all influenced percentage error (P < .0001). Core interobserver percentage error (medians, 11.4%, 10.2%, and 9.3% for BA using one, two, and three beats, respectively) was approximately twice the intraobserver percentage error (medians, 6.3%, 4.9%, and 4.2% for BA using one, two, and three beats, respectively). Slopes and calculated variables exhibited high percentage error despite BA. Chamber dimensions, areas, velocities, and time intervals exhibited low percentage error. CONCLUSIONS: This comprehensive evaluation of quantitative echocardiographic methods will provide a valuable resource for the design of future pediatric studies. BA and a single core lab observer improve the reproducibility of echocardiographic measurements in children with dilated cardiomyopathy. Certain measurements are highly reproducible, while others, despite BA, are poorly reproducible.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/epidemiología , Ecocardiografía/estadística & datos numéricos , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/epidemiología , Adolescente , Adulto , Niño , Preescolar , Comorbilidad , Humanos , Aumento de la Imagen/métodos , Lactante , Recién Nacido , Masculino , Tamaño de los Órganos , Prevalencia , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Estados Unidos/epidemiología , Adulto Joven
20.
Arch Pediatr Adolesc Med ; 162(9): 882-5, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18762608

RESUMEN

OBJECTIVE: To investigate the incidence of aortic root dilatation in pectus excavatum. DESIGN: Retrospective medical record review and echocardiographic reanalysis. SETTING: Morgan Stanley Children's Hospital of New York-Presbyterian. PARTICIPANTS: Surgical candidates with pectus excavatum (n = 37) and age-matched controls (n = 44) referred for an echocardiogram from 1994 to 2002. INTERVENTIONS: Two-dimensional and color Doppler transthoracic echocardiograms. OUTCOME MEASURES: The aortic annulus and root were measured and z scores were calculated and compared. Medical records were reviewed for genetic evaluation. RESULTS: Patients with pectus excavatum and age-matched controls were reanalyzed. There was no difference in age, weight, height, or body surface area between patients and controls. There were no differences in the mean aortic annulus diameter, mean aortic annulus z score, or mean aortic root measurements. However, the aortic root z score was significantly higher in the pectus excavatum group compared with the controls: 0.9 (SD, 1.06) vs 0.0 (SD, 1.25) (P = .001). There were more patients with an aortic root z score of 2 or greater in the pectus excavatum group (9 of 37 patients) than in the control group (0 of 43 controls), with a calculated odds ratio of 29.7 (95% confidence interval, 1.10-1.59). Genetic evaluation was performed in 5 patients with a pectus excavatum and dilated aortic root; 2 of them received diagnoses of Marfan syndrome. CONCLUSIONS: Aortic root dilatation is more common in patients with pectus excavatum than in a control population. Echocardiographic screening may be useful in the identification of aortic root dilatation in patients with isolated pectus excavatum.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Tórax en Embudo/diagnóstico por imagen , Síndrome de Marfan/diagnóstico por imagen , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Niño , Dilatación Patológica , Ecocardiografía , Femenino , Humanos , Masculino , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA