Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Gynecol Oncol ; 23(1): 48-52, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22355467

RESUMEN

OBJECTIVE: To report the clinical presentation and oncologic outcomes of a series of patients who presented with an abdominal or pelvic mass and were diagnosed with a gastrointestinal stromal tumor (GIST). METHODS: Data were obtained on all patients who presented with an abdominal or pelvic mass between September 2007 and June 2010 and who were ultimately diagnosed with a GIST. The patients' medical records were reviewed. A literature review was also conducted. RESULTS: Six patients were identified who met the inclusion criteria. All six patients had a tumor in the intestinal tract arising from the small bowel. The mean tumor size was 12 cm (range, 6 to 22 cm). A complete resection was achieved in five of the six patients. There were no intraoperative complications; one patient had a postoperative complication. Two patients were treated with imatinib after surgery. The mean follow-up time was 32 months (range, 0.3 to 40 months). At the last follow-up, five of the six patients were without any evidence of disease. One patient died of an unrelated hepatic encephalopathy. The incidence in our institution is 3%. CONCLUSION: GISTs are uncommon; however, they should be considered in the differential diagnosis of patients presenting with an abdominal or pelvic mass.

2.
J Vasc Interv Radiol ; 14(2 Pt 1): 195-203, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12582187

RESUMEN

PURPOSE: To report the midterm results of the endovascular treatment of complicated type-B aortic dissection with use of stent-grafts. MATERIALS AND METHODS: Ten patients with acute (n = 4) or chronic (n = 6) complicated type-B dissection were treated with custom-made stent-grafts. Indications for treatment included uncontrollable hypertension with dissection extension (n = 3), renal ischemia (n = 1), and false lumen aneurysm (n = 6). Stainless-steel Z-stents covered with polyester grafts were placed in the initial six patients. Nitinol stents covered with ultrathin polytetrafluoroethylene were used in the remaining four patients. The patients were followed-up with helical computed tomography for a maximum of 30 months (mean, 20 mo). RESULTS: There was one technical failure related to the access site. Early complications included deep venous thrombosis (n = 1) and embolic stroke (n = 1). Complete thrombosis of the thoracic false lumen was achieved in six patients and partial thrombosis was achieved in three. Aneurysms developed at the ends of the stainless-steel stents in two patients, requiring additional stent-graft placement. Despite successful remodeling of the thoracic aorta, three of four patients with distal reentry into the abdominal aorta experienced progressive abdominal aortic aneurysm (AAA). AAA rupture developed in two patients; one rupture was fatal and the other was treated with emergency surgery. CONCLUSIONS: Endovascular treatment of complicated type-B aortic dissection is technically feasible and effective. Closely monitoring the treated aorta is essential to detect early aneurysm formation at the ends of rigid stents. Despite adequate sealing of the tears in the thoracic aorta, dissection with distal reentry phenomenon into the abdominal aorta may evolve into AAA with late rupture.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Stents , Aleaciones , Disección Aórtica/diagnóstico por imagen , Aneurisma de la Aorta/diagnóstico por imagen , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Politetrafluoroetileno , Acero Inoxidable , Factores de Tiempo , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA