1.
Iran Red Crescent Med J ; 15(3): 183-6, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23983995

RESUMEN

BACKGROUND: Respiratory failure is a major problem in neonatal medicine in all over the world and has different causes. Using mechanical ventilation is one of its major treatments. OBJECTIVES: Different strategies have been expressed in this context, including high frequency mechanical ventilation. PATIENTS AND METHODS: This study is a prospective randomized clinical trial conducted on all newborns with respiratory failure hospitalized in the NICU of Tehran vali-asr Hospital during 2009.These patients were divided in to two groups through block Randomization method; conventional mechanical ventilation group and high frequency ventilation group. RESULTS: Intraventricular hemorrhage (IVH) and air leak (e.g. pneumothorax) were less in HFPPV group than conventional group (P = 0.012 and P = 0.038). The mean time needed for mechanical ventilation was lower in HFPPV group, but this difference was not statistically significant (P = 0.922). Needing to O2 in 28 days of age was almost equal in both groups (P = 0. 99). Mortality, and refractory hypoxia and PVL were lower in HFPPV group, but the difference was not statistically significant (P = 0.301, P = 0. 508, P = 0. 113). CONCLUSIONS: Treatment of neonatal respiratory failure with high rate mechanical ventilation may reduce some complications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA