RESUMEN
Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.
Asunto(s)
Velocidad del Flujo Sanguíneo , Encéfalo , Circulación Cerebrovascular , Ultrasonografía , Humanos , Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Circulación Cerebrovascular/fisiología , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Errores Médicos , Relación Señal-Ruido , Piel , Cráneo , Somnolencia/fisiología , Ultrasonografía/instrumentación , Ultrasonografía/métodos , AdultoRESUMEN
OBJECTIVE: Peripheral nerves remain a challenging target for medical imaging, given their size, anatomical complexity, and structural heterogeneity. Quantitative ultrasound (QUS) applies a set of techniques to estimate tissue acoustic parameters independent of the imaging platform. Many useful medical and laboratory applications for QUS have been reported, but challenges remain for deployment in vivo, especially for heterogeneous tissues. Several phenomena introduce variability in attenuation estimates, which may influence the estimation of other QUS parameters. For example, estimating the backscatter coefficient (BSC) requires compensation for the attenuation of overlying tissues between the transducer and the underlying tissue of interest. The purpose of this study is to extend prior studies by investigating the efficacy of several analytical methods of estimating attenuation compensation on QUS outcomes in the human median nerve. METHODS: Median nerves were imaged at the volar wrist in vivo and beam-formed radiofrequency (RF) data were acquired. Six analytical approaches for attenuation compensation were compared: 1-2) attenuation estimated by applying spectral difference method (SDM) and spectral log difference method (SLDM) independently to regions of interest (ROIs) overlying the nerve and to the nerve ROI itself; 3-4) attenuation estimation by applying SDM and SLDM to ROIs overlying the nerve, and transferring these properties to the nerve ROI; and 5-6) methods that apply previously published values of tissue attenuation to the measured thickness of each overlying tissue. Mean between-subject estimates of BSC-related outcomes as well as within-subject variability of these outcomes were compared among the 6 methods. RESULTS: Compensating for attenuation using SLDM and values from the literature reduced variability in BSC-based outcomes, compared to SDM. Variability in attenuation coefficients contributes substantially to variability in backscatter measurements. CONCLUSION: This work has implications for the application of QUS to in vivo diagnostic assessments in peripheral nerves and possibly other heterogeneous tissues.
RESUMEN
This study evaluated the repeatability and reproducibility of using high-frequency quantitative ultrasound (QUS) measurement of backscatter coefficient (BSC), grayscale analysis, and gray-level co-occurrence matrix (GLCM) textural analysis, to characterize human rotator cuff muscles. The effects of varying scanner settings across two different operators and two US systems were investigated in a healthy volunteer with normal rotator cuff muscles and a patient with chronic massive rotator cuff injury and substantial muscle degeneration. The results suggest that BSC is a promising method for assessing rotator cuff muscles in both control and pathological subjects, even when operators were free to adjust system settings (depth, level of focus, and time-gain compensation). Measurements were repeatable and reproducible across the different operators and ultrasound imaging platforms. In contrast, grayscale and GLCM analyses were found to be less reliable in this setting, with significant measurement variability. Overall, the repeatability and reproducibility measurements of BSC indicate its potential as a diagnostic tool for rotator cuff muscle evaluation.
Asunto(s)
Tejido Adiposo , Manguito de los Rotadores , Humanos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/patología , Reproducibilidad de los Resultados , Tejido Adiposo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , UltrasonografíaRESUMEN
Individuals experiencing chronic homelessness have high rates of persistent co-occurring mental health and substance use disorders (COD), and they often have difficulty with service engagement and retention, resulting in symptom exacerbation and housing loss. This study pilot tested Maintaining Independence and Sobriety Through Systems Integration, Outreach and Networking (MISSION), a multicomponent wraparound treatment approach to improve COD symptoms and housing stability among individuals experiencing chronic homelessness and persistent COD. This open pilot study enrolled and assessed 109 individuals with a COD experiencing chronic homelessness and offered one year of MISSION. Statistically significant improvements were observed in behavioral health symptoms and functioning, days of illicit drug use, and housing stability. By treatment completion, 85% of participants were referred to social and behavioral supports. This pilot study demonstrates that MISSION helped to successfully engage participants in treatment, reduce substance use and mental health symptoms, and improve housing outcomes.
Asunto(s)
Personas con Mala Vivienda , Trastornos Mentales , Trastornos Relacionados con Sustancias , Humanos , Personas con Mala Vivienda/psicología , Trastornos Relacionados con Sustancias/terapia , Masculino , Femenino , Proyectos Piloto , Adulto , Persona de Mediana Edad , Trastornos Mentales/terapia , Diagnóstico Dual (Psiquiatría) , ViviendaRESUMEN
Ultrasound (US) is an important imaging tool for skeletal muscle analysis. The advantages of US include point-of-care access, real-time imaging, cost-effectiveness, and absence of ionizing radiation. However, US can be highly dependent on the operator and/or US system, and a portion of the potentially useful information carried by raw sonographic data is discarded in image formation for routine qualitative US. Quantitative ultrasound (QUS) methods provide analysis of the raw or post-processed data, revealing additional information about normal tissue structure and disease status. There are four QUS categories that can be used on muscle and are important to review. First, quantitative data derived from B-mode images can help determine the macrostructural anatomy and microstructural morphology of muscle tissues. Second, US elastography can provide information about muscle elasticity or stiffness through strain elastography or shear wave elastography (SWE). Strain elastography measures the induced tissue strain caused either by internal or external compression by tracking tissue displacement with detectable speckle in B-mode images of the examined tissue. SWE measures the speed of induced shear waves traveling through the tissue to estimate the tissue elasticity. These shear waves may be produced using external mechanical vibrations or internal "push pulse" ultrasound stimuli. Third, raw radiofrequency signal analyses provide estimates of fundamental tissue parameters, such as the speed of sound, attenuation coefficient, and backscatter coefficient, which correspond to information about muscle tissue microstructure and composition. Lastly, envelope statistical analyses apply various probability distributions to estimate the number density of scatterers and quantify coherent to incoherent signals, thus providing information about microstructural properties of muscle tissue. This review will examine these QUS techniques, published results on QUS evaluation of skeletal muscles, and the strengths and limitations of QUS in skeletal muscle analysis.
Asunto(s)
Compresión de Datos , Diagnóstico por Imagen de Elasticidad , Ultrasonografía , Músculo Esquelético/diagnóstico por imagen , Frecuencia CardíacaRESUMEN
Background MRI-derived proton density fat fraction (PDFF) is an accurate, reliable, and safe biologic marker for use in the noninvasive diagnosis of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD). Because of the cost and limited availability of MRI, it is necessary to develop an accurate method to diagnose NAFLD with potential point-of-care access. Purpose To compare the diagnostic accuracy of the quantitative US (QUS) fat fraction (FF) estimator with that of the controlled attenuation parameter (CAP) in the diagnosis of NAFLD using contemporaneous MRI-derived PDFF as the reference standard. Materials and Methods Participants with or suspected of having NAFLD were prospectively recruited at the NAFLD Research Center between July 2015 and July 2019. All participants underwent MRI-derived PDFF measurement, transient elastography with CAP measurement, and QUS. QUS FF was derived using computed QUS parameters from the acquired radiofrequency US data using a calibrated reference phantom. The area under the receiver operating characteristic curve (AUC) was calculated to assess the accuracy of QUS FF and CAP in the diagnosis of hepatic steatosis (defined as MRI-derived PDFF ≥ 5%). AUCs were compared using the DeLong test. Results A total of 123 participants were included (mean age, 52 years ± 13 [SD]; 67 [54%] women). Of these participants, 100 (81%) had MRI-derived PDFF of 5% or more. QUS FF had a significantly higher AUC for diagnosis of NAFLD than did CAP (0.92 [95% CI: 0.87, 0.98] vs 0.79 [95% CI: 0.67, 0.90], P = .03). QUS FF had a sensitivity of 98% (98 of 100) and a specificity of 48% (11 of 23). CAP had a sensitivity of 87% (87 of 100) and a specificity of 57% (13 of 23). Conclusion The quantitative US fat fraction estimator is more accurate than the controlled attenuation parameter in the diagnosis of hepatic steatosis in patients with or suspected of having nonalcoholic fatty liver disease. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Ito in this issue.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Estudios Prospectivos , Protones , Estándares de ReferenciaRESUMEN
OBJECTIVES: To compare the diagnostic accuracy of US shear wave elastography (SWE) and magnetic resonance elastography (MRE) for classifying fibrosis stage in patients with nonalcoholic fatty liver disease (NAFLD). METHODS: Patients from a prospective single-center cohort with clinical liver biopsy for known or suspected NAFLD underwent contemporaneous SWE and MRE. AUCs for classifying biopsy-determined liver fibrosis stages ≥ 1, ≥ 2, ≥ 3, and = 4, and their respective performance parameters at cutoffs providing ≥ 90% sensitivity or specificity were compared between SWE and MRE. RESULTS: In total, 100 patients (mean age, 51.8 ± 12.9 years; 46% males; mean BMI 31.6 ± 4.7 kg/m2) with fibrosis stage distribution (stage 0/1/2/3/4) of 43, 36, 5, 10, and 6%, respectively, were included. AUCs (and 95% CIs) for SWE and MRE were 0.65 (0.54-0.76) and 0.81 (0.72-0.89), 0.81 (0.71-0.91) and 0.94 (0.89-1.00), 0.85 (0.74-0.96) and 0.95 (0.89-1.00), and 0.91 (0.79-1.00) and 0.92 (0.83-1.00), for detecting fibrosis stage ≥ 1, ≥ 2, ≥ 3, and = 4, respectively. The differences were significant for detecting fibrosis stage ≥ 1 and ≥ 2 (p < 0.01) but not otherwise. At ≥ 90% sensitivity cutoff, MRE yielded higher specificity than SWE at diagnosing fibrosis stage ≥ 1, ≥ 2, and ≥ 3. At ≥ 90% specificity cutoff, MRE yielded higher sensitivity than SWE at diagnosing fibrosis stage ≥ 1 and ≥ 2. CONCLUSIONS: In adults with NAFLD, MRE was more accurate than SWE in diagnosing stage ≥ 1 and ≥ 2 fibrosis, but not stage ≥ 3 or 4 fibrosis. KEY POINTS: ⢠For detecting any fibrosis or mild fibrosis, MR elastography was significantly more accurate than shear wave elastography. ⢠For detecting advanced fibrosis and cirrhosis, MRE and SWE did not differ significantly in accuracy. ⢠For excluding advanced fibrosis and potentially ruling out the need for biopsy, SWE and MRE did not differ significantly in negative predictive value. ⢠Neither SWE nor MRE had sufficiently high positive predictive value to rule in advanced fibrosis.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Adulto , Biopsia , Femenino , Fibrosis , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Estudios ProspectivosRESUMEN
OBJECTIVES: To develop and evaluate deep learning models devised for liver fat assessment based on ultrasound (US) images acquired from four different liver views: transverse plane (hepatic veins at the confluence with the inferior vena cava, right portal vein, right posterior portal vein) and sagittal plane (liver/kidney). METHODS: US images (four separate views) were acquired from 135 participants with known or suspected nonalcoholic fatty liver disease. Proton density fat fraction (PDFF) values derived from chemical shift-encoded magnetic resonance imaging served as ground truth. Transfer learning with a deep convolutional neural network (CNN) was applied to develop models for diagnosis of fatty liver (PDFF ≥ 5%), diagnosis of advanced steatosis (PDFF ≥ 10%), and PDFF quantification for each liver view separately. In addition, an ensemble model based on all four liver view models was investigated. Diagnostic performance was assessed using the area under the receiver operating characteristics curve (AUC), and quantification was assessed using the Spearman correlation coefficient (SCC). RESULTS: The most accurate single view was the right posterior portal vein, with an SCC of 0.78 for quantifying PDFF and AUC values of 0.90 (PDFF ≥ 5%) and 0.79 (PDFF ≥ 10%). The ensemble of models achieved an SCC of 0.81 and AUCs of 0.91 (PDFF ≥ 5%) and 0.86 (PDFF ≥ 10%). CONCLUSION: Deep learning-based analysis of US images from different liver views can help assess liver fat.
Asunto(s)
Hígado , Redes Neurales de la Computación , Humanos , Hígado/diagnóstico por imagen , Aprendizaje AutomáticoRESUMEN
The risk-need-responsivity (RNR) model suggests several key practices for justice-involved populations under correctional supervision. Behavioral health treatment planning aligned with RNR principles for offender populations with co-occurring mental health and substance use disorders (CODs) could be one method for integrating RNR into clinical care. To explore a unique approach to working with behavioral health and RNR principles, the authors implemented a mixed-methods feasibility study of the acceptability, usability, and utility of a newly developed RNR treatment planning support tool (RNR TST). The tool was implemented in a re-entry program serving adults with co-occurring mental health and opioid use disorders. Chart reviews of RNR TSTs (N = 55) and a focus group (N = 14 re-entry clinical staff) were conducted. Ninety-six percent of the RNR TSTs incorporated the use of a validated risk-need assessment and 70% of the RNR TSTs were semi-complete to complete. Focus group interviews highlighted behavioral health staff perspectives on the acceptability, usability, and utility of the RNR TST. This novel RNR TST has the potential to assist behavioral health providers in integrating RNR principles into treatment planning. Further development and testing are needed to determine its impact on client care and outcomes.
Asunto(s)
Criminales , Psiquiatría , Trastornos Relacionados con Sustancias , Adulto , Estudios de Factibilidad , Planificación en Salud , Humanos , Salud Mental , Trastornos Relacionados con Sustancias/terapiaRESUMEN
Background Radiofrequency ultrasound data from the liver contain rich information about liver microstructure and composition. Deep learning might exploit such information to assess nonalcoholic fatty liver disease (NAFLD). Purpose To develop and evaluate deep learning algorithms that use radiofrequency data for NAFLD assessment, with MRI-derived proton density fat fraction (PDFF) as the reference. Materials and Methods A HIPAA-compliant secondary analysis of a single-center prospective study was performed for adult participants with NAFLD and control participants without liver disease. Participants in the parent study were recruited between February 2012 and March 2014 and underwent same-day US and MRI of the liver. Participants were randomly divided into an equal number of training and test groups. The training group was used to develop two algorithms via cross-validation: a classifier to diagnose NAFLD (MRI PDFF ≥ 5%) and a fat fraction estimator to predict MRI PDFF. Both algorithms used one-dimensional convolutional neural networks. The test group was used to evaluate the classifier for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy and to evaluate the estimator for correlation, bias, limits of agreements, and linearity between predicted fat fraction and MRI PDFF. Results A total of 204 participants were analyzed, 140 had NAFLD (mean age, 52 years ± 14 [standard deviation]; 82 women) and 64 were control participants (mean age, 46 years ± 21; 42 women). In the test group, the classifier provided 96% (95% confidence interval [CI]: 90%, 99%) (98 of 102) accuracy for NAFLD diagnosis (sensitivity, 97% [95% CI: 90%, 100%], 68 of 70; specificity, 94% [95% CI: 79%, 99%], 30 of 32; positive predictive value, 97% [95% CI: 90%, 99%], 68 of 70; negative predictive value, 94% [95% CI: 79%, 98%], 30 of 32). The estimator-predicted fat fraction correlated with MRI PDFF (Pearson r = 0.85). The mean bias was 0.8% (P = .08), and 95% limits of agreement were -7.6% to 9.1%. The predicted fat fraction was linear with an MRI PDFF of 18% or less (r = 0.89, slope = 1.1, intercept = 1.3) and nonlinear with an MRI PDFF greater than 18%. Conclusion Deep learning algorithms using radiofrequency ultrasound data are accurate for diagnosis of nonalcoholic fatty liver disease and hepatic fat fraction quantification when other causes of steatosis are excluded. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Lockhart and Smith in this issue.
Asunto(s)
Redes Neurales de la Computación , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Ultrasonografía/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Ondas de Radio , Distribución Aleatoria , Sensibilidad y EspecificidadRESUMEN
Background Advanced confounder-corrected chemical shift-encoded MRI-derived proton density fat fraction (PDFF) is a leading parameter for fat fraction quantification in nonalcoholic fatty liver disease (NAFLD). Because of the limited availability of this MRI technique, there is a need to develop and validate alternative parameters to assess liver fat. Purpose To assess relationship of quantitative US parameters to MRI PDFF and to develop multivariable quantitative US models to detect hepatic steatosis and quantify hepatic fat. Materials and Methods Adults with known NAFLD or who were suspected of having NAFLD were prospectively recruited between August 2015 and February 2019. Participants underwent quantitative US and chemical shift-encoded MRI liver examinations. Liver biopsies were performed if clinically indicated. The correlation between seven quantitative US parameters and MRI PDFF was evaluated. By using leave-one-out cross validation, two quantitative US multivariable models were evaluated: a classifier to differentiate participants with NAFLD versus participants without NAFLD and a fat fraction estimator. Classifier performance was summarized by area under the receiver operating characteristic curve and area under the precision-recall curve. Fat fraction estimator performance was evaluated by correlation, linearity, and bias. Results Included were 102 participants (mean age, 52 years ± 13 [standard deviation]; 53 women), 78 with NAFLD (MRI PDFF ≥ 5%). A two-variable classifier yielded a cross-validated area under the receiver operating characteristic curve of 0.89 (95% confidence interval: 0.82, 0.96) and an area under the precision-recall curve of 0.96 (95% confidence interval: 0.93, 0.99). The cross-validated fat fraction predicted by a two-variable fat fraction estimator was correlated with MRI PDFF (Spearman ρ = 0.82 [P < .001]; Pearson r = 0.76 [P < .001]). The mean bias was 0.02% (P = .97), and 95% limits of agreement were ±12.0%. The predicted fat fraction was linear with MRI PDFF (Râ2 = 0.63; slope, 0.69; intercept, 4.3%) for MRI PDFF of 34% or less. Conclusion A multivariable quantitative US approach yielded excellent correlation with MRI proton density fat fraction for hepatic steatosis assessment in nonalcoholic fatty liver disease. © RSNA, 2020 Online supplemental material is available for this article.
Asunto(s)
Hígado Graso/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Estudios Prospectivos , Ultrasonografía/métodosRESUMEN
Liver fibrosis is a histological hallmark of most chronic liver diseases, which can progress to cirrhosis and liver failure, and predisposes to hepatocellular carcinoma. Accurate diagnosis of liver fibrosis is necessary for prognosis, risk stratification, and treatment decision-making. Liver biopsy, the reference standard for assessing liver fibrosis, is invasive, costly, and impractical for surveillance and treatment response monitoring. Elastography offers a noninvasive, objective, and quantitative alternative to liver biopsy. This article discusses the need for noninvasive assessment of liver fibrosis and reviews the comparative advantages and limitations of ultrasound and magnetic resonance elastography techniques with respect to their basic concepts, acquisition, processing, and diagnostic performance. Variations in clinical contexts of use and common pitfalls associated with each technique are considered. In addition, current challenges and future directions to improve the diagnostic accuracy and clinical utility of elastography techniques are discussed. Level of Evidence: 5 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:25-42.
Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Humanos , Hígado/diagnóstico por imagenRESUMEN
OBJECTIVES: To assess the feasibility of using ultrasound (US) image features related to the median nerve echogenicity and shape for carpal tunnel syndrome (CTS) diagnosis. METHODS: In 31 participants (21 healthy participants and 10 patients with CTS), US images were collected with a 30-MHz transducer from median nerves at the wrist crease in 2 configurations: a neutral position and with wrist extension. Various morphologic features, including the cross-sectional area (CSA), were calculated to assess the nerve shape. Carpal tunnel syndrome commonly results in loss of visualization of the nerve fascicular pattern on US images. To assess this phenomenon, we developed a nerve-tissue contrast index (NTI) method. The NTI is a ratio of average brightness levels of surrounding tissue and the median nerve, both calculated on the basis of a US image. The area under the curve (AUC) from a receiver operating characteristic curve analysis and t test were used to assess the usefulness of the features for differentiation of patients with CTS from control participants. RESULTS: We obtained significant differences in the CSA and NTI parameters between the patients with CTS and control participants (P < .01), with the corresponding highest AUC values equal to 0.885 and 0.938, respectively. For the remaining investigated morphologic features, the AUC values were less than 0.685, and the differences in means between the patients and control participants were not statistically significant (P > .10). The wrist configuration had no impact on differences in average parameter values (P > .09). CONCLUSIONS: Patients with CTS can be differentiated from healthy individuals on the basis of the median nerve CSA and echogenicity. Carpal tunnel syndrome is not manifested in a change of the median nerve shape that could be related to circularity or contour variability.
Asunto(s)
Síndrome del Túnel Carpiano/diagnóstico por imagen , Nervio Mediano/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Diagnóstico Diferencial , Estudios de Factibilidad , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Articulación de la Muñeca/diagnóstico por imagenRESUMEN
OBJECTIVES: To assess inter-platform reproducibility of ultrasonic attenuation coefficient (AC) and backscatter coefficient (BSC) estimates in adults with known/suspected nonalcoholic fatty liver disease (NAFLD). METHODS: This HIPAA-compliant prospective study was approved by an institutional review board; informed consent was obtained. Participants with known/suspected NAFLD were recruited and underwent same-day liver examinations with clinical ultrasound scanner platforms from two manufacturers. Each participant was scanned by the same trained sonographer who performed multiple data acquisitions in the right liver lobe using a lateral intercostal approach. Each data acquisition recorded a B-mode image and the underlying radio frequency (RF) data. AC and BSC were calculated using the reference phantom method. Inter-platform reproducibility was evaluated for AC and log-transformed BSC (logBSC = 10log10BSC) by intraclass correlation coefficient (ICC), Pearson's correlation, Bland-Altman analysis with computation of limits of agreement (LOAs), and within-subject coefficient of variation (wCV; applicable to AC). RESULTS: Sixty-four participants were enrolled. Mean AC values measured using the two platforms were 0.90 ± 0.13 and 0.94 ± 0.15 dB/cm/MHz while mean logBSC values were - 30.6 ± 5.0 and - 27.9 ± 5.6 dB, respectively. Inter-platform ICC was 0.77 for AC and 0.70 for log-transformed BSC in terms of absolute agreement. Pearson's correlation coefficient was 0.81 for AC and 0.80 for logBSC. Ninety-five percent LOAs were - 0.21 to 0.13 dB/cm/MHz for AC, and - 9.48 to 3.98 dB for logBSC. The wCV was 7% for AC. CONCLUSIONS: Hepatic AC and BSC are reproducible across two different ultrasound platforms in adults with known or suspected NAFLD. KEY POINTS: ⢠Ultrasonic attenuation coefficient and backscatter coefficient are reproducible between two different ultrasound platforms in adults with NAFLD. ⢠This inter-platform reproducibility may qualify quantitative ultrasound biomarkers for generalized clinical application in patients with suspected/known NAFLD.
Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los ResultadosRESUMEN
OBJECTIVES: To assess inter-sonographer reproducibility of ultrasound attenuation coefficient (AC), backscatter coefficient (BSC) and shear wave speed (SWS) in adults with known/suspected non-alcoholic fatty liver disease (NAFLD). METHODS: The institutional review board approved this HIPAA-compliant prospective study; informed consent was obtained. Participants with known/suspected NAFLD were recruited and underwent same-day liver examinations with a clinical scanner. Each participant was scanned by two of the six trained sonographers. Each sonographer performed multiple data acquisitions in the right liver lobe using a lateral intercostal approach. A data acquisition was a single operator button press that recorded a B-mode image, radio-frequency data, and the SWS value. AC and BSC were calculated from the radio-frequency data using the reference phantom method. SWS was calculated automatically using product software. Intraclass correlation coefficient (ICC) and within-subject coefficient of variation (wCV) were calculated for applicable metrics. RESULTS: Sixty-one participants were recruited. Inter-sonographer ICC was 0.86 (95% confidence interval: 0.77-0.92) for AC and 0.87 (0.78-0.92) for log-transformed BSC (logBSC = 10log10BSC) using one acquisition per sonographer. ICC was 0.88 (0.80-0.93) for both AC and logBSC averaging 5 acquisitions. ICC for SWS was 0.57 (0.29-0.74) using one acquisition per sonographer, and 0.84 (0.66-0.93) using 10 acquisitions. The wCV was ~7% for AC, and 19-43% for SWS, depending on number of acquisitions. CONCLUSIONS: Hepatic AC, BSC and SWS measures on a clinical scanner have good inter-sonographer reproducibility in adults with known or suspected NAFLD. Multiple acquisitions are required for SWS but not AC or BSC to achieve good inter-sonographer reproducibility. KEY POINTS: ⢠AC, BSC and SWS measurements are reproducible in adults with NAFLD. ⢠Inter-sonographer reproducibility of SWS measurement improves with more acquisitions being averaged. ⢠Multiple acquisitions are required for SWS but not AC or BSC.
Asunto(s)
Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Ultrasonografía/normas , Adulto , Análisis de Varianza , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Fantasmas de Imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Programas InformáticosRESUMEN
OBJECTIVES: To assess the repeatability and reproducibility of the ultrasonic attenuation coefficient (AC) and backscatter coefficient (BSC) measured in the livers of adults with known or suspected nonalcoholic fatty liver disease (NAFLD). METHODS: The Institutional Review Board approved this Health Insurance Portability and Accountability Act-compliant prospective study; informed consent was obtained. Forty-one research participants with known or suspected NAFLD were recruited and underwent same-day ultrasound examinations of the right liver lobe with a clinical scanner by a clinical sonographer. Each participant underwent 2 scanning trials, with participant repositioning between trials. Two transducers were used in each trial. For each transducer, machine settings were optimized by the sonographer but then kept constant while 3 data acquisitions were obtained from the liver without participant repositioning and then from an external calibrated phantom. Raw RF echo data were recorded. The AC and BSC were measured within 2.6 to 3.0 MHz from a user-defined hepatic field of interest from each acquisition. The repeatability and reproducibility were analyzed by random-effects models. RESULTS: The mean AC and log-transformed BSC (logBSC) were 0.94 dB/cm-MHz and -27.0 dB, respectively. Intraclass correlation coefficients were 0.88 to 0.94 for the AC and 0.87 to 0.95 for the logBSC acquired without participant repositioning. For between-trial repeated scans with participant repositioning, the intraclass correlation coefficients were 0.80 to 0.84 for the AC and 0.69 to 0.82 for the logBSC after averaging results from 3 within-trial images. The variability introduced by the transducer was less than the repeatability error. CONCLUSIONS: Hepatic AC and BSC measures using a reference phantom technique on a clinical scanner are repeatable and reproducible between transducers in adults with known or suspected NAFLD.
Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los ResultadosRESUMEN
There are two well-known ultrasonic approaches to extract sets of quantitative parameters: Lizzi-Feleppa (LF) parameters: slope, intercept, and midband; and quantitative ultrasound (QUS)-derived parameters: effective scatterer diameter (ESD) and effective acoustic concentration (EAC). In this study, the relation between the LF and QUS-derived parameters is studied theoretically and experimentally on ex vivo mouse livers. As expected from the theory, LF slope is correlated to ESD ([Formula: see text]), and from experimental data, LF midband is correlated to EAC ([Formula: see text]). However, LF intercept is not correlated to ESD ([Formula: see text]) nor EAC ([Formula: see text]). The unexpected correlation observed between LF slope and EAC ([Formula: see text]) results likely from the high correlation between ESD and EAC due to the inversion process. For a liver fat percentage estimation, an important potential medical application, the parameters presenting the better correlation are EAC ([Formula: see text]) and LF midband ([Formula: see text]).
Asunto(s)
Hígado Graso/diagnóstico por imagen , Hígado/diagnóstico por imagen , Ultrasonografía/métodos , Animales , Modelos Animales de Enfermedad , Estudios de Evaluación como Asunto , Ratones , Ratones Endogámicos C57BLRESUMEN
UNLABELLED: Magnetic resonance elastography (MRE), an advanced magnetic resonance-based imaging technique, and acoustic radiation force impulse (ARFI), an ultrasound-based imaging technique, are accurate for diagnosing nonalcoholic fatty liver disease (NAFLD) fibrosis. However, no head-to-head comparisons between MRE and ARFI for diagnosing NAFLD fibrosis have been performed. We compared MRE versus ARFI head-to-head for diagnosing fibrosis in well-characterized patients with biopsy-proven NAFLD. This cross-sectional analysis of a prospective cohort involved 125 patients (54.4% female) who underwent MRE, ARFI, and contemporaneous liver biopsies scored using the Nonalcoholic Steatohepatitis Clinical Research Network histological scoring system. The performances of MRE versus ARFI for diagnosing fibrosis were evaluated using area under the receiver operating characteristic curves (AUROCs). The mean (± standard deviation) age and body mass index were 48.9 (±15.4) years and 31.8 (±7.0) kg/m(2) , respectively. For diagnosing any fibrosis (≥ stage 1), the MRE AUROC was 0.799 (95% confidence interval [CI] 0.723-0.875), significantly (P = 0.012) higher than the ARFI AUROC of 0.664 (95% CI 0.568-0.760). In stratified analysis by presence or absence of obesity, MRE was superior to ARFI for diagnosing any fibrosis in obese patients (P < 0.001) but not in nonobese patients (P = 0.722). The MRE AUROCs for diagnosing ≥stages 2, 3, and 4 fibrosis were 0.885 (95% CI 0.816-0.953), 0.934 (95% CI 0.863-1.000), and 0.882 (95% CI 0.729-1.000); and the ARFI AUROCs were 0.848 (95% CI 0.776-0.921), 0.896 (95% CI 0.824-0.968), and 0.862 (95% CI 0.721-1.000). MRE had higher AUROCs than ARFI for discriminating dichotomized fibrosis stages at all dichotomization cutoff points, but the AUROC differences decreased as the cutoff points (fibrosis stages) increased. CONCLUSION: MRE is more accurate than ARFI for diagnosing any fibrosis in NAFLD patients, especially those who are obese.
Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico , Adulto , Biopsia , Estudios Transversales , Femenino , Humanos , Cirrosis Hepática/etiología , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/patología , Estudios ProspectivosRESUMEN
OBJECTIVES: Evidence for complementary therapies as important strategies to relieve cancer treatment-associated symptoms is increasing. Mostly, these complementary therapies start at the end of adjuvant treatments, resulting in a long delay until the well-being of patients is addressed. Further, long distances between the rehabilitation center and the patients' residence hinder patients' compliance. METHODS: The multimodal outpatient LOTUS Care Cure Project (LCCP) was tested in a randomized controlled trial including patients of various cancer entities and stages while on adjuvant chemotherapy and/or radiotherapy or outpatient aftercare. The intervention group received the LCCP additionally to the conventional treatment (LCCP group, n = 50). The control group (CG) was split into 2 groups, with (CG1, n = 33) and without (CG2, n = 17) weekly talks. The primary endpoint was quality of life (QoL) after 3 months. RESULTS: In the LCCP group, QoL significantly improved after 3 months compared to CG2 (p = 0.022) but not compared to CG1. Other parameters showing a significant improvement were cognitive (p < 0.05, vs. CG1 and CG2) and social function (p < 0.05, vs. CG2). CONCLUSIONS: This pilot study describes a multimodal outpatient complementary therapy program conducted in parallel with conventional therapies and its potential to significantly improve QoL and reduce treatment-associated side effects. To substantiate these data, multicenter trials are needed.