Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Am J Transplant ; 17(8): 2215-2220, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28724206

RESUMEN

BACKGROUND: Legionnaires' disease, a severe pneumonia, is typically acquired through inhalation of aerosolized water containing Legionella bacteria. Legionella can grow in the complex water systems of buildings, including health care facilities. Effective water management programs could prevent the growth of Legionella in building water systems. METHODS: Using national surveillance data, Legionnaires' disease cases were characterized from the 21 jurisdictions (20 U.S. states and one large metropolitan area) that reported exposure information for ≥90% of 2015 Legionella infections. An assessment of whether cases were health care-associated was completed; definite health care association was defined as hospitalization or long-term care facility residence for the entire 10 days preceding symptom onset, and possible association was defined as any exposure to a health care facility for a portion of the 10 days preceding symptom onset. All other Legionnaires' disease cases were considered unrelated to health care. RESULTS: A total of 2,809 confirmed Legionnaires' disease cases were reported from the 21 jurisdictions, including 85 (3%) definite and 468 (17%) possible health care-associated cases. Among the 21 jurisdictions, 16 (76%) reported 1-21 definite health care-associated cases per jurisdiction. Among definite health care-associated cases, the majority (75, 88%) occurred in persons aged ≥60 years, and exposures occurred at 72 facilities (15 hospitals and 57 long-term care facilities). The case fatality rate was 25% for definite and 10% for possible health care-associated Legionnaires' disease. CONCLUSIONS AND IMPLICATIONS FOR PUBLIC HEALTH PRACTICE: Exposure to Legionella from health care facility water systems can result in Legionnaires' disease. The high case fatality rate of health care-associated Legionnaires' disease highlights the importance of case prevention and response activities, including implementation of effective water management programs and timely case identification.


Asunto(s)
Infección Hospitalaria/epidemiología , Instituciones de Salud/estadística & datos numéricos , Enfermedad de los Legionarios/epidemiología , Vigilancia de la Población , Microbiología del Agua , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Brotes de Enfermedades , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Tiempo , Estados Unidos/epidemiología , Adulto Joven
2.
Lett Appl Microbiol ; 53(2): 225-30, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21623848

RESUMEN

AIMS: To evaluate the efficacy of chlorine dioxide (ClO(2)) against seven species of bacterial threat (BT) agents in water. METHODS AND RESULTS: Two strains of Bacillus anthracis spores, Yersinia pestis, Francisella tularensis, Burkholderia pseudomallei, Burkholderia mallei and Brucella species were each inoculated into a ClO(2) solution with an initial concentration of 2.0 (spores only) and 0.25 mg l(-1) (all other bacteria) at pH 7 or 8, 5 or 25°C. At 0.25 mg l(-1) in potable water, six species were inactivated by at least three orders of magnitude within 10 min. Bacillus anthracis spores required up to 7 h at 5°C for the same inactivation with 2.0 mg l(-1) ClO(2). CONCLUSIONS: Typical ClO(2) doses used in water treatment facilities would be effective against all bacteria tested except B. anthracis spores that would require up to 7 h with the largest allowable dose of 2 mg l(-1) ClO(2). Other water treatment processes may be required in addition to ClO(2) disinfection for effective spore removal or inactivation. SIGNIFICANCE AND IMPACT OF STUDY: The data obtained from this study provide valuable information for water treatment facilities and public health officials in the event that a potable water supply is contaminated with these BT agents.


Asunto(s)
Bacterias/efectos de los fármacos , Compuestos de Cloro/toxicidad , Desinfectantes/toxicidad , Desinfección/métodos , Óxidos/toxicidad , Esporas Bacterianas/efectos de los fármacos , Microbiología del Agua , Bacillus anthracis/efectos de los fármacos , Burkholderia mallei/efectos de los fármacos , Burkholderia pseudomallei/efectos de los fármacos , Descontaminación/métodos , Francisella tularensis/efectos de los fármacos , Salud Pública , Purificación del Agua/métodos , Yersinia pestis/efectos de los fármacos
3.
Lett Appl Microbiol ; 52(1): 84-6, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21189486

RESUMEN

AIMS: To determine the range of free available chlorine (FAC) required for disinfection of the live vaccine strain (LVS) and wild-type strains of Francisella tularensis. METHODS AND RESULTS: Seven strains of planktonic F. tularensis were exposed to 0·5 mg·l(-1) FAC for two pH values, 7 and 8, at 5 and 25°C. LVS was inactivated 2 to 4 times more quickly than any of the wild-type F. tularensis strains at pH 8 and 5°C. CONCLUSIONS: Free available chlorine residual concentrations routinely maintained in drinking water distribution systems would require up to two hours to reduce all F. tularensis strains by 4 log10. LVS was inactivated most quickly of the tested strains. SIGNIFICANCE AND IMPACT OF THE STUDY: This work provides contact time (CT) values that are useful for drinking water risk assessment and also suggests that LVS may not be a good surrogate in disinfection studies.


Asunto(s)
Cloro/farmacología , Desinfectantes/farmacología , Desinfección , Francisella tularensis/efectos de los fármacos , Cloro/química , Desinfectantes/química , Concentración de Iones de Hidrógeno , Temperatura , Abastecimiento de Agua/análisis
4.
Infect Control Hosp Epidemiol ; 29(1): 57-62, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18171188

RESUMEN

OBJECTIVE: To investigate the cause(s) of an increased incidence of clinical cultures growing Mycobacterium abscessus at a hospital in Florida. DESIGN: Outbreak investigation. SETTING: University-affiliated, tertiary-care hospital. METHODS: A site visit was done during the first week of September 2006. We reviewed the medical records of patients from whom M. abscessus was recovered during the period from January 1, 2003, through June 30, 2006. We collected environmental samples from various sites and evaluated specimen processing procedures in the microbiology laboratory. Isolates of M. abscessus recovered from the environment and from 12 randomly selected patients who sought medical care in 2006 were compared by pulsed-field gel electrophoresis (PFGE). Follow-up case surveillance was continued through March 31, 2007. RESULTS: Specimens from 143 patients obtained from various anatomical sites grew M. abscessus on culture in 2005-2006, compared with specimens from 21 patients in 2003-2004. The 12 isolates from patients that were selected for molecular typing had indistinguishable PFGE patterns. Observations revealed no major breaches in the processing of mycobacterial specimens in the laboratory. Isolates grew only after prolonged incubation (mean +/- SD, 45 +/- 15 days) in test tubes containing diagonally oriented Middlebrook and Cohn 7H10 agar or Lowenstein-Jensen medium. Environmental samples obtained from the inside of the specimen incubator grew M. abscessus on culture. A test tube containing diagonally oriented, uninoculated Middlebrook and Cohn 7H10 agar that was incubated in the same incubator as clinical specimens grew M. abscessus with a PFGE pattern that matched the pattern of the patient isolates. Cases of M. abscessus infection decreased to baseline after the hospital changed suppliers of mycobacterial media and cleaned the incubator. CONCLUSIONS: Although the source was never confirmed, our investigation suggests that this was a pseudo-outbreak of M. abscessus infection that resulted from contamination of mycobacterial cultures during incubation. Our findings emphasize the need for guidance on the disinfection of specimen incubators.


Asunto(s)
Infección Hospitalaria/epidemiología , Brotes de Enfermedades , Contaminación de Equipos , Laboratorios de Hospital , Infecciones por Mycobacterium no Tuberculosas/epidemiología , Micobacterias no Tuberculosas/aislamiento & purificación , Técnicas Bacteriológicas , Infección Hospitalaria/microbiología , Electroforesis en Gel de Campo Pulsado/métodos , Humanos , Control de Infecciones , Infecciones por Mycobacterium no Tuberculosas/microbiología
5.
J Thorac Cardiovasc Surg ; 103(3): 582-8, 1992 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1545559

RESUMEN

Autologous blood transfusion is a common method of reducing the need for heterologous blood transfusion during cardiac operations. Recently we investigated an outbreak of severe, nonsurgical postoperative bleeding among patients undergoing heart operations and receiving intraoperative transfusion of blood from a cell conservation device (Cell Saver System, Haemonetics Corp., Braintree, Mass.). As a result of this investigation, we conducted a prospective study to determine if bacterial or endotoxin contamination of the blood collected in the Cell Saver System and used for reinfusion during heart operations contributes to postoperative bleeding complications. Patients' blood samples were collected immediately before operation, at the end of cardiopulmonary bypass, 1 hour postoperatively, and from the Cell Saver System. All blood samples were cultured for bacteria, and all plasma samples were assayed for endotoxin. Preoperatively all patients having heart operations were without signs of infection, 33 of 37 blood cultures taken were negative, and none of the plasma samples had detectable endotoxin. After discontinuance of cardiopulmonary bypass but before delivery of blood from the Cell Saver System, bacteria and endotoxin were detected in 11 of 36 (30.6%) and five of 35 (14.3%) of the patients' blood samples, respectively. The blood aspirated from the open chest and collected by the Cell Saver System was culture positive in 30 of 31 (96.8%) samples, and seven of 29 (24.1%) contained endotoxin. One of 28 blood samples collected 1 hour postoperatively was culture positive, and five of 25 samples contained endotoxin. Of 61 total microorganisms isolated, 50 (82%) were coagulase-negative staphylococci, four (6.6%) aerobic diphtheroids, five (8.2%) anaerobic "diphtheroids" (Propionibacterium acnes), and two (3.2%) gram-negative bacilli. Plasma endotoxin concentrations ranged from 10 to 765 pg/ml. No signs of endotoxemia or unusual bleeding were observed intraoperatively or postoperatively in any of the 38 patients. Although blood collected in the Cell Saver System and used for reinfusion during heart operations often was contaminated with gram-positive bacterial commensals of the skin and low concentrations of endotoxin, no adverse effects were noted in the patients.


Asunto(s)
Bacterias/aislamiento & purificación , Transfusión de Sangre Autóloga , Sangre/microbiología , Procedimientos Quirúrgicos Cardíacos , Endotoxinas/sangre , Transfusión de Sangre Autóloga/instrumentación , Humanos , Estudios Prospectivos
6.
Pediatr Infect Dis J ; 13(12): 1110-6, 1994 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-7892080

RESUMEN

For identification of risk factors for bloodstream infection (BSI) among neonatal intensive care unit patients, prospective 6-month studies in three neonatal intensive care units were conducted. BSI was diagnosed in 42 of 376 (11.2%) enrolled infants. Pathogens included coagulase-negative staphylococci, Candida sp., Group B streptococci and Gram-negative species. Patients with BSIs were more likely to die during their neonatal intensive care unit stay than were patients who did not acquire BSIs (6 of 42 vs. 11 of 334, P = 0.007). BSI rate was highest in infants with birth weight < 1500 g (relative risk (RR) = 6.8, P < 0.001), those treated with H-2 blockers (RR = 4.2, P < 0.001) or theophylline (RR = 2.8, P < 0.001) and those with admission diagnoses referable to the respiratory tract (RR = 3.7, P < 0.001). Infants who developed BSI were more severely ill on admission than other infants (median physiologic stability index 13 vs. 10 (P < 0.001) and were of lower gestational age (28 vs. 35 weeks, P < 0.001). In logistic regression analysis, risk of BSI was independently associated only with very low birth weight, respiratory admission diagnoses and receipt of H-2 blockers. Risk of isolation of a pathogen from blood culture was independently associated with Broviac, umbilical vein or peripheral venous catheterization > 10, 7 or 3 days, respectively, at one insertion site. Rate of isolation of a pathogen was higher (9 of 59 (15%)) within 48 hours of a measurable serum interleukin 6 concentration than an interleukin 6 level of 0 pg/ml (10 of 159 (6%), P = 0.04).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Interleucina-6/sangre , Sepsis/epidemiología , Biomarcadores/sangre , Femenino , Humanos , Incidencia , Mortalidad Infantil , Recién Nacido de Bajo Peso , Recién Nacido , Masculino , Análisis Multivariante , Proyectos Piloto , Estudios Prospectivos , Factores de Riesgo , Sepsis/microbiología , Sepsis/fisiopatología , Índice de Severidad de la Enfermedad , Análisis de Supervivencia
7.
Infect Control Hosp Epidemiol ; 12(9): 535-9, 1991 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1940276

RESUMEN

OBJECTIVE: In this study, we measured microbial growth and endotoxin production in the intravenous anesthetic propofol using 10 different microbial strains; 6 isolated from outbreak cases and 4 from laboratory stock cultures. DESIGN: In each trial, endotoxin-free glass tubes containing 10 ml propofol were inoculated with 10(0)-10(3) CFU/ml of the test organism and incubated at 30 degrees C for 72 hours. SETTING: In May and June 1990, the Centers for Disease Control received reports of 5 outbreaks in 5 states of postsurgical patient infections and/or pyrogenic reactions. Epidemiologic and laboratory investigations implicated extrinsic contamination of an intravenous anesthetic, propofol, as the probable source of these outbreaks. RESULTS: After 24 hours, 9 of the 10 cultures increased in viable counts by 3 to 6 logs. At least 1 ng/ml of endotoxin was produced within 24 hours by Escherichia coli, Enterobacter cloacae, and Acinetobacter calcoaceticus subspecies anitratus. CONCLUSIONS: Propofol can support rapid microbial growth and endotoxin production. To avoid infectious complications, scrupulous aseptic technique should be used when preparing or administering this anesthetic.


Asunto(s)
Anestesia Intravenosa , Candida albicans/crecimiento & desarrollo , Contaminación de Medicamentos , Endotoxinas/biosíntesis , Bacterias Gramnegativas/crecimiento & desarrollo , Propofol/química , Asepsia/métodos , Asepsia/normas , Humanos , Temperatura
8.
Infect Control Hosp Epidemiol ; 20(11): 746-51, 1999 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10580625

RESUMEN

OBJECTIVE: To investigate an outbreak of gram-negative bacteremias at a hemodialysis center (December 1, 1996-January 31, 1997). DESIGN: Retrospective cohort study. Reviewed infection control practices and maintenance and disinfection procedures for the water system and dialysis machines. Performed cultures of the water and dialysis machines, including the waste-handling option (WHO), a drain port designed to dispose of saline used to flush the dialyzer before patient use. Compared isolates by pulsed-field gel electrophoresis. SETTING: A hemodialysis center in Maryland. RESULTS: 94 patients received dialysis on 27 machines; 10 (11%) of the patients had gram-negative bacteremias. Pathogens causing these infections were Enterobacter cloacae (n = 6), Pseudomonas aeruginosa (n = 4), and Escherichia coli (n = 2); two patients had polymicrobial bacteremia. Factors associated with development of gram-negative bacteremias were receiving dialysis via a central venous catheter (CVC) rather than via an arterio-venous shunt (all 10 infected patients had CVCs compared to 31 of 84 uninfected patients, relative risk [RR] undefined; P<.001) or dialysis on any of three particular dialysis machines (7 of 10 infected patients were exposed to the three machines compared to 20 of 84 uninfected patients, RR = 5.8; P = .005). E cloacae, P aeruginosa, or both organisms were grown from cultures obtained from several dialysis machines. WHO valves, which prevent backflow from the drain to dialysis bloodlines, were faulty in 8 (31%) of 26 machines, including 2 of 3 machines epidemiologically linked to case-patients. Pulsed-field gel electrophoresis patterns of available dialysis machine and patient E cloacae isolates were identical. CONCLUSIONS: Our study suggests that WHO ports with incompetent valves and resultant backflow were a source of cross-contamination of dialysis bloodlines and patients' CVCs. Replacement of faulty WHO valves and enhanced disinfection of dialysis machines terminated the outbreak.


Asunto(s)
Infección Hospitalaria/etiología , Brotes de Enfermedades , Infecciones por Bacterias Gramnegativas/etiología , Diálisis Renal/efectos adversos , Instituciones de Atención Ambulatoria , Estudios de Cohortes , Infección Hospitalaria/epidemiología , Falla de Equipo , Infecciones por Bacterias Gramnegativas/epidemiología , Humanos , Maryland/epidemiología , Diálisis Renal/instrumentación , Estudios Retrospectivos , Factores de Riesgo
9.
Infect Control Hosp Epidemiol ; 15(2): 82-7, 1994 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8201239

RESUMEN

BACKGROUND: A cluster of bacterial contamination of platelets occurred at a university hospital in a one-month period. This unusual clustering allowed us to examine the likely mechanism of contamination and clinical sequelae. METHODS: We reviewed medical records of patients receiving random donor platelet transfusions to determine numbers of platelets transfused, reactions reported, and episodes of bacterial contamination. We also reviewed procedures at the collecting blood agencies and the hospital blood bank. RESULTS: Four patients received bacterially contaminated platelets during June and July 1991. The rates of reported platelet transfusion reactions increased significantly (P < 0.001) from September 1989 through July 1991 (study period); in addition, the rate of contamination of platelets during June and July 1991 was 23-fold higher than during the previous 21 months (P < 0.001). Surveillance methodology changed dramatically during the study period, contributing to the recognition of the current cluster. Pathogens isolated from the contaminated platelet pools were Bacillus cereus, Staphylococcus epidermidis, or Pseudomonas aeruginosa in titers ranging from 10(6) to 10(8) colony forming units/mL. Four constituent individual platelet units identified as the probable cause of the outbreak (including one postepidemic episode) were significantly older (mean age, 4.8 days) than 106 randomly selected individual platelet units (mean age, 3.7 days; P = 0.04). Platelet pools were transfused an average of 2.5 hours after pooling. Review of blood collection and platelet preparation practices did not identify breaks in procedure or technique that could have caused contamination. CONCLUSIONS: Increased awareness of platelet transfusion reactions by clinical staff and routine culturing of all platelets associated with transfusion reactions will identify contaminated platelets. Identification of contaminated platelets is necessary to treat affected patients appropriately and to determine the prevalence of and risk factors for contaminated platelets (Infect Control Hosp Epidemiol 1994;15:82-87).


Asunto(s)
Bacteriemia/epidemiología , Bacteriemia/etiología , Plaquetas/microbiología , Infección Hospitalaria/epidemiología , Infección Hospitalaria/etiología , Brotes de Enfermedades , Hospitales Universitarios , Control de Infecciones , Transfusión de Plaquetas/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Almacenamiento de Sangre/métodos , Recolección de Muestras de Sangre/métodos , Análisis por Conglomerados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo
10.
Infect Control Hosp Epidemiol ; 18(10): 704-9, 1997 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9350463

RESUMEN

OBJECTIVES: To determine risk factors for Serratia marcescens infection or colonization, and to identify the source of the pathogen and factors facilitating its persistence in a neonatal intensive-care unit (NICU) during an outbreak. DESIGN: Retrospective case-control study; review of NICU infection control policies, soap use, and handwashing practices among healthcare workers (HCWs); and selected environmental cultures. SETTING: A university-affiliated tertiary-care hospital NICU. PATIENTS: All NICU infants with at least one positive culture for S marcescens during August 1994 to October 1995. Infants who did not develop S marcescens infection or colonization were selected randomly as controls. RESULTS: Thirty-two patients met the case definition. On multivariate analysis, independent risk factors for S marcescens infection or colonization were having very low birth weight (< 1,500 g), a patent ductus arteriosus, a mother with chorioamnionitis, or exposure to a single HCW. During January to July 1995, NICU HCWs carried their own bottles of 1% chlorxylenol soap, which often were left standing inverted in the NICU sink and work areas. Cultures of 16 (31%) of 52 samples of soap and 1 (8%) of 13 sinks yielded S marcescens. The 16 samples of soap all came from opened 4-oz bottles carried by HCWs. DNA banding patterns of case infant, HCW soap bottle, and sink isolates were identical. CONCLUSIONS: Extrinsically contaminated soap contributed to an outbreak of S marcescens infection. Very-low-birth-weight infants with multiple invasive procedures and exposures to certain HCWs were at greatest risk of S marcescens infection or colonization.


Asunto(s)
Antiinfecciosos Locales , Infección Hospitalaria/transmisión , Brotes de Enfermedades , Unidades de Cuidado Intensivo Neonatal , Infecciones por Serratia/transmisión , Serratia marcescens , Jabones , Xilenos , Estudios de Casos y Controles , Trazado de Contacto , Femenino , Servicio de Limpieza en Hospital , Humanos , Recién Nacido , Masculino , Estudios Retrospectivos , Factores de Riesgo
11.
Infect Control Hosp Epidemiol ; 20(3): 171-5, 1999 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10100542

RESUMEN

OBJECTIVE: To study vancomycin-resistant Enterococcus (VRE) prevalence, risk factors, and clustering among hospital inpatients. DESIGN: Rectal-swab prevalence culture survey conducted from February 5 to March 22, 1996. SETTING: The Veterans' Affairs Medical Center, Atlanta, Georgia. PATIENTS: Hospital (medical and surgical) inpatients. RESULTS: The overall VRE prevalence was 29% (42/147 patients). The VRE prevalence was 52% (38/73 patients) among patients who had received at least one of six specific antimicrobials during the preceding 120 days, compared with only 5% (4/74) among those who had not received the antimicrobials (relative risk, 9.6; P<.001). The longer the period (up to 120 days) during which antimicrobial use was studied, the more closely VRE status was predicted. Among 67 hospital patients in 28 multibed rooms, clustering of VRE among current roommates was not found. CONCLUSIONS: At this hospital with relatively high VRE prevalence, VRE colonization was related to antibiotic use but not to roommate VRE status. In hospitals with a similar VRE epidemiology, obtaining cultures from roommates of VRE-positive patients may not be as efficient a strategy for identifying VRE-colonized patients as obtaining screening cultures from patients who have received antimicrobials.


Asunto(s)
Antibacterianos/farmacología , Bacteriemia/epidemiología , Infección Hospitalaria/epidemiología , Enterococcus/aislamiento & purificación , Infecciones por Bacterias Grampositivas/epidemiología , Hospitales de Veteranos/estadística & datos numéricos , Vancomicina/farmacología , Anciano , Bacteriemia/microbiología , Bacteriemia/transmisión , Infección Hospitalaria/microbiología , Infección Hospitalaria/transmisión , Transmisión de Enfermedad Infecciosa , Farmacorresistencia Microbiana , Electroforesis en Gel de Campo Pulsado , Enterococcus/efectos de los fármacos , Femenino , Georgia/epidemiología , Infecciones por Bacterias Grampositivas/microbiología , Infecciones por Bacterias Grampositivas/transmisión , Humanos , Cuidados a Largo Plazo , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo
12.
Am J Infect Control ; 25(5): 377-80, 1997 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9343619

RESUMEN

OBJECTIVE: This study was carried out to determine whether needleless intravenous access devices are more likely to allow microorganisms to enter the fluid pathway than intravenous needle-access devices. METHODS: A laboratory study was conducted with two needleless and one intravenous needle-access devices and Enterococcus faecium as a bacterial challenge. Inocula of E. faecium were prepared on the basis of the numerical estimates of 1000 to 10,000 colony-forming units (CFU)/cm2 of bacterial flora on dry regions of skin (arms, legs, and hands). The septum of each access device was inoculated with 10 to 20 microliters of a 10(4) to 10(5) CFU/ml challenge suspension, which was allowed to dry on the surface of the septum. In the first part of the experiment, the needleless or needle-access cannula of each device was used to puncture the corresponding septum without previously disinfecting the top of the septum. In the second part, the contaminated septum was punctured after disinfecting the septum with a 70% isopropyl alcohol wipe. After each puncture, trypticase soy broth was flushed through the fluid pathway of the intravenous access device, collected, and cultured by the membrane filtration technique. The septum of each injection-site cap and the needleless or needle-access cannula were sampled with sterile premoistened swabs. Swabs were cultured on blood agar plates. RESULTS: The rate of fluid pathway contamination was 100% (40/40) for one of the needleless intravenous access devices and 80% (20/25) for the other when septa were contaminated with E. faecium and not disinfected before puncture. The rate for the intravenous needle-access device was 72% (18/25). When the septa of the three different devices tested were disinfected with 70% isopropyl alcohol, E. faecium was isolated on only one septum from all devices tested in part two (1/74, 1.3%). CONCLUSIONS: These laboratory studies demonstrate that there is no statistically significant difference in the rate of fluid pathway contamination between needleless and intravenous needle-access devices. However, if the septa of either needleless or needle systems are not disinfected before puncture, a high rate of fluid pathway contamination may occur.


Asunto(s)
Catéteres de Permanencia/microbiología , Enterococcus faecium/patogenicidad , Contaminación de Equipos , Infusiones Intravenosas/instrumentación , Lesiones por Pinchazo de Aguja/microbiología , Lesiones por Pinchazo de Aguja/prevención & control , Diseño de Equipo , Humanos , Control de Infecciones/métodos , Modelos Teóricos , Agujas , Lesiones por Pinchazo de Aguja/etiología
13.
Am J Infect Control ; 26(2): 111-2, 1998 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-9584804

RESUMEN

In response to a reported hospital outbreak traced to the use of contaminated ice in 1968, the Centers for Disease Control and Prevention (CDC) developed an advisory regarding the sanitary care and maintenance of ice-storage chests and ice-making machines. CDC has revised this unpublished advisory several times during the years to respond to requests for guidance from infection control professionals. Because CDC continues to receive inquiries about this topic from infection control professionals, this advisory is being published.


Asunto(s)
Contaminación de Alimentos/prevención & control , Hielo , Control de Infecciones/normas , Servicio de Mantenimiento e Ingeniería en Hospital/normas , Refrigeración/instrumentación , Saneamiento/normas , Centers for Disease Control and Prevention, U.S. , Equipos y Suministros de Hospitales , Guías como Asunto , Humanos , Control de Infecciones/métodos , Saneamiento/métodos , Estados Unidos
14.
Am J Infect Control ; 26(4): 437-41, 1998 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9721399

RESUMEN

BACKGROUND: Sporadic reports of increased infection rates involving concerning access systems, especially in home-care setting, have raised questions concerning the safety of all needleless systems. Addressing this concern, Baxter Healthcare Corporation and the Centers for Disease Control an d Prevention performed parallel laboratory studies comparing the microbial barrier properties of the Interlink (trademark of Baxter Healthcare Corporation, Deerfield, Ill) needleless system with a conventional intravenous access system. METHODS: Studies of needleless and conventional systems evaluated fluid path contamination introduced through injection site septa, which were intentionally inoculated with high levels of bacteria and subsequently punctured with a without alcohol swabbing disinfection before access. RESULTS: With disinfection, the combined effects of the disinfection technique and the barrier properties of the septa prevented the transfer of organisms into the fluid path in 94% to 96% of needleless test articles and 96% to 100% of conventional test articles. Without disinfection, the barrier properties of the septa alone prevented the transfer of organisms into the fluid path in 20% to 69% of needleless test article and 10% to 28% of conventional test articles. CONCLUSIONS: The data demonstrate the needless system performs as well as the conventional intravenous access system with respect to the risk of microbial contamination and reinforce the need for appropriate septum disinfection before accessing either system.


Asunto(s)
Catéteres de Permanencia/microbiología , Desinfección/métodos , Control de Infecciones/métodos , Infusiones Intravenosas/instrumentación , 2-Propanol/farmacología , Antiinfecciosos Locales/farmacología , Catéteres de Permanencia/efectos adversos , Diseño de Equipo , Seguridad de Equipos , Control de Infecciones/instrumentación , Agujas , Sensibilidad y Especificidad
15.
Infect Dis Clin North Am ; 15(3): 797-812, viii, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11570142

RESUMEN

Infectious complications of hemodialysis include bacterial infections caused by contaminated water or equipment, other bacterial infections (including vascular access infections), and bloodborne viruses (primarily the hepatitis B and C viruses). Infections caused by contaminated water and equipment can be prevented by a well-designed water-treatment system, routine cleaning and disinfection of system components, and routine bacteriologic monitoring of dialysis water and dialysis fluid. Standard precautions with additional measures recommended specifically for dialysis centers will prevent transmission of bacteria and viruses from patient to patient. These precautions include routine use of gloves, handwashing, and cleaning and disinfection of the external surface of the dialysis machine and other environmental surfaces. In addition, preventing transmission of hepatitis B virus infection requires vaccination of susceptible patients and staff, avoiding dialyzer reuse, and use of a dedicated room, dialysis machine, and staff members when treating patients chronically infected with this virus.


Asunto(s)
Unidades de Hemodiálisis en Hospital , Control de Infecciones , Infecciones/etiología , Diálisis Renal/efectos adversos , Unidades de Hemodiálisis en Hospital/normas , Humanos , Diálisis Renal/instrumentación , Abastecimiento de Agua
16.
ASAIO J ; 44(1): 98-107, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9466509

RESUMEN

Chronic hemodialysis centers in the United States were surveyed in 1995 regarding a number of hemodialysis associated diseases and practices. A total of 2,647 centers, representing 224,954 patients and 54,194 staff members, responded. Seventy-seven percent of centers reported that they reused disposable dialyzers. At the end of 1995, 65% of patients were treated with an arteriovenous graft, 22% an arteriovenous fistula, and 13% a temporary or permanent central catheter. By the end of 1995, at least three doses of hepatitis B vaccine had been administered to 35% of patients and to 82% of staff members. Acute infection with the hepatitis B virus (HBV) occurred in 0.06% of patients, and was more likely to be reported by centers with lower proportions of patients vaccinated against HBV. The prevalence of antibody to hepatitis C virus (HCV) was 10.4% among patients and 2.0% among staff. At least one patient with vancomycin resistant enterococci (VRE) was reported by 11.5% of centers, more commonly by hospital (vs freestanding centers not located in hospitals) and government centers, and centers located in certain geographic areas. Vancomycin was received by 7.2% of patients in December 1995. The percentage of centers reporting patients with other pathogens was 7.9% for active tuberculosis, 39% for human immunodeficiency virus (HIV), and 40% for methicillin resistant Staphylococcus aureus (MRSA).


Asunto(s)
Vigilancia de la Población , Diálisis Renal/efectos adversos , Derivación Arteriovenosa Quirúrgica , Catéteres de Permanencia , Equipo Reutilizado , Infecciones por VIH/epidemiología , Infecciones por VIH/etiología , Hepatitis B/epidemiología , Hepatitis B/etiología , Hepatitis C/epidemiología , Hepatitis C/etiología , Humanos , Incidencia , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/etiología , Encuestas y Cuestionarios , Tuberculosis/epidemiología , Tuberculosis/etiología , Estados Unidos/epidemiología
17.
Nephrol News Issues ; 13(6): 18, 23, 27, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10603845

RESUMEN

Testing for the presence or absence of chemical germicides in hemodialysis is a critical component to assure patient safety. It is necessary to verify early prepared solutions are being used and rinsed out of devices (water treatment systems, dialysis machines, hemodialyzers), and to make sure equipment is working properly to remove drinking water disinfectants. It is important to use tests and procedures that have FDA clearance for use specifically in hemodialysis or, in the case of chlorine, the recommended test for detecting residual free and total chlorine as referenced in the Standard Methods for the Analysis of Water and Wastewater. Products without specific labeling for dialysis should be avoided. Positive and negative controls should be included to validate testing.


Asunto(s)
Infección Hospitalaria/prevención & control , Desinfección/métodos , Contaminación de Equipos/prevención & control , Diálisis Renal/métodos , Purificación del Agua/métodos , Humanos , Fallo Renal Crónico/terapia , Microbiología del Agua
19.
Appl Environ Microbiol ; 72(6): 4429-30, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16751562

RESUMEN

A protocol to recover Bacillus anthracis spores from a steel surface using macrofoam swabs was evaluated for its accuracy, precision, reproducibility, and limit of detection. Macrofoam swabs recovered 31.7 to 49.1% of spores from 10-cm2 steel surfaces with a < or =32.7% coefficient of variation in sampling precision and reproducibility for inocula of > or =38 spores.


Asunto(s)
Bacillus anthracis/aislamiento & purificación , Bacillus anthracis/fisiología , Acero , Técnicas Bacteriológicas , Reproducibilidad de los Resultados , Esporas Bacterianas/aislamiento & purificación , Esporas Bacterianas/fisiología
20.
ASAIO Trans ; 35(3): 314-6, 1989.
Artículo en Inglés | MEDLINE | ID: mdl-2688713

RESUMEN

The Centers for Disease Control (CDC) have received reports of bacteremia in patients on high flux dialysis attributed to contamination of dialyzer header spaces or o-rings. A study was performed in which header spaces and o-rings of Hemoflow F-80 dialyzers (Fresenius AG, Bad Homburg, FRG) were exposed to an aqueous suspension of Xanthomonas maltophilia and Mycobacterium chelonae for 1 hour. After exposure, the dialyzers were reprocessed manually with 4% formaldehyde, 4% Renalin, 2.5% Renalin, or sterile water (SW) as a control, or with an automated reprocessing machine using 3.25% Renalin. After 48 hours the blood compartment (BC) was drained and rinsed twice with 500 ml of SW. Each BC sample was cultured. To simulate dialysis, separate circulates of SW were pumped through the DC and the BC. After 15 minutes, the BC circulate was cultured, headers were unscrewed, and o-rings, header caps, and fiber bundle ends were cultured. For each germicide, bacteria were recovered in low numbers, primarily from the o-rings and the o-ring groove in the header caps. In 38 tests, a total of 60 of 342 assays (17.5%) were positive. In only one of these tests one bacterial colony forming unit (cfu) was recovered from the BC circulate during simulated dialysis. It was concluded that if header spaces and o-rings are contaminated, bacteria could be sealed protectively from the germicide. However, concentrations of surviving bacteria were low, probably outside the BC, and did not effectively contaminate the BC circulate during simulated dialysis.


Asunto(s)
Adhesión Bacteriana/efectos de los fármacos , Desinfección , Fallo Renal Crónico/microbiología , Riñones Artificiales , Sepsis/microbiología , Esterilización , Técnicas Bacteriológicas , Desinfectantes/farmacología , Humanos , Fallo Renal Crónico/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA