1.
Sensors (Basel) ; 22(12)2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35746377

RESUMEN

In hard X-ray applications that require high detection efficiency and short response times, such as synchrotron radiation-based Mössbauer absorption spectroscopy and time-resolved fluorescence or photon beam position monitoring, III-V-compound semiconductors, and dedicated alloys offer some advantages over the Si-based technologies traditionally used in solid-state photodetectors. Amongst them, gallium arsenide (GaAs) is one of the most valuable materials thanks to its unique characteristics. At the same time, implementing charge-multiplication mechanisms within the sensor may become of critical importance in cases where the photogenerated signal needs an intrinsic amplification before being acquired by the front-end electronics, such as in the case of a very weak photon flux or when single-photon detection is required. Some GaAs-based avalanche photodiodes (APDs) were grown by a molecular beam epitaxy to fulfill these needs; by means of band gap engineering, we realised devices with separate absorption and multiplication region(s) (SAM), the latter featuring a so-called staircase structure to reduce the multiplication noise. This work reports on the experimental characterisations of gain, noise, and charge collection efficiencies of three series of GaAs APDs featuring different thicknesses of the absorption regions. These devices have been developed to investigate the role of such thicknesses and the presence of traps or defects at the metal-semiconductor interfaces responsible for charge loss, in order to lay the groundwork for the future development of very thick GaAs devices (thicker than 100 µm) for hard X-rays. Several measurements were carried out on such devices with both lasers and synchrotron light sources, inducing photon absorption with X-ray microbeams at variable and controlled depths. In this way, we verified both the role of the thickness of the absorption region in the collection efficiency and the possibility of using the APDs without reaching the punch-through voltage, thus preventing the noise induced by charge multiplication in the absorption region. These devices, with thicknesses suitable for soft X-ray detection, have also shown good characteristics in terms of internal amplification and reduction of multiplication noise, in line with numerical simulations.

2.
J Synchrotron Radiat ; 28(Pt 2): 410-418, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33650552

RESUMEN

It has been shown previously both in vitro and in vivo that microbeam irradiation (MBI) can control malignant tumour cells more effectively than the clinically established concepts of broad beam irradiation. With the aim to extend the international capacity for microbeam research, the first MBI experiment at the biomedical beamline SYRMEP of the Italian synchrotron facility ELETTRA has been conducted. Using a multislit collimator produced by the company TECOMET, arrays of quasi-parallel microbeams were successfully generated with a beam width of 50 µm and a centre-to-centre distance of 400 µm. Murine melanoma cell cultures were irradiated with a target dose of approximately 65 Gy at a mean photon energy of ∼30 keV with a dose rate of 70 Gy s-1 and a peak-to-valley dose of ∼123. This work demonstrated a melanoma cell reduction of approximately 80% after MBI. It is suggested that, while a high energy is essential to achieve high dose rates in order to deposit high treatment doses in a short time in a deep-seated target, for in vitro studies and for the treatment of superficial tumours a spectrum in the lower energy range might be equally suitable or even advantageous.


Asunto(s)
Fotones , Sincrotrones , Animales , Ratones , Método de Montecarlo
3.
J Synchrotron Radiat ; 27(Pt 2): 503-506, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32153291

RESUMEN

The vertical intensity distribution of synchrotron-based X-ray beams usually has a Gaussian profile encompassing large intensity variations. For biomedical imaging applications this may entail sub-optimal dose distributions and large fluctuations in terms of image noise. Commonly, planar metallic filters coupled with absorbing slits systems are applied to adjust the delivered flux and to limit intensity variations, respectively. The latter results in a reduction of the effective beam size. A flattening filter that counterbalances the transverse inhomogeneity, while retaining a sufficient flux, has been developed in the context of a monochromatic phase-contrast breast computed tomography application, ongoing at the Elettra synchrotron facility. The implementation of the new filtration system results in homogeneous intensity (hence dose) distribution and signal-to-noise ratio across the imaged volume. Finally, and most importantly, it allows a wider portion of the beam to be used, directly translating into a major (∼40%) reduction of the overall scan time for samples requiring a field of view larger than the beam size (i.e. multiple translation steps).


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Simulación por Computador , Diseño de Equipo , Femenino , Humanos , Mamografía/instrumentación , Dosis de Radiación , Relación Señal-Ruido , Sincrotrones
4.
J Synchrotron Radiat ; 27(Pt 3): 762-771, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32381779

RESUMEN

This study relates to the INFN project SYRMA-3D for in vivo phase-contrast breast computed tomography using the SYRMEP synchrotron radiation beamline at the ELETTRA facility in Trieste, Italy. This peculiar imaging technique uses a novel dosimetric approach with respect to the standard clinical procedure. In this study, optimization of the acquisition procedure was evaluated in terms of dose delivered to the breast. An offline dose monitoring method was also investigated using radiochromic film dosimetry. Various irradiation geometries have been investigated for scanning the prone patient's pendant breast, simulated by a 14 cm-diameter polymethylmethacrylate cylindrical phantom containing pieces of calibrated radiochromic film type XR-QA2. Films were inserted mid-plane in the phantom, as well as wrapped around its external surface, and irradiated at 38 keV, with an air kerma value that would produce an estimated mean glandular dose of 5 mGy for a 14 cm-diameter 50% glandular breast. Axial scans were performed over a full rotation or over 180°. The results point out that a scheme adopting a stepped rotation irradiation represents the best geometry to optimize the dose distribution to the breast. The feasibility of using a piece of calibrated radiochromic film wrapped around a suitable holder around the breast to monitor the scan dose offline is demonstrated.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Dosimetría por Película , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Italia , Dosis de Radiación , Sincrotrones
5.
Eur Radiol ; 30(5): 2740-2750, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31974689

RESUMEN

OBJECTIVES: To evaluate and compare the image quality of propagation-based phase-contrast computed tomography (PB-CT) using synchrotron radiation and conventional cone-beam breast computed tomography (CBBCT) based on various radiological image quality criteria. METHODS: Eight excised breast tissue samples of various sizes and containing different lesion types were scanned using PB-CT at a synchrotron facility and using CBBCT at a university-affiliated breast imaging centre. PB-CT scans were performed at two different mean glandular dose (MGD) levels: standard (5.8 mGy) and low (1.5 mGy), for comparison with CBBCT scans at the standard MGD (5.8 mGy). Image quality assessment was carried out using six quality criteria and six independent medical imaging experts in a reading room with mammography workstations. The interobserver agreement between readers was evaluated using intraclass correlation coefficient (ICC), and image quality was compared between the two breast imaging modalities using the area under the visual grading characteristic curve (AUCVGC). RESULTS: Interobserver agreement between the readers showed moderate reliability for five image criteria (ICC: ranging from 0.488 to 0.633) and low reliability for one criterion (image noise) (ICC 0.307). For five image quality criteria (overall quality, perceptible contrast, lesion sharpness, normal tissue interfaces, and calcification visibility), both standard-dose PB-CT images (AUCVGC 0.958 to 1, p ≤ .05) and low dose PB-CT images (AUCVGC 0.785 to 0.834, p ≤ .05) were of significantly higher image quality than standard-dose CBBCT images. CONCLUSIONS: Synchrotron-based PB-CT can achieve a significantly higher radiological image quality at a substantially lower radiation dose compared with conventional CBBCT. KEY POINTS: • PB-CT using synchrotron radiation results in higher image quality than conventional CBBCT for breast imaging. • PB-CT using synchrotron radiation requires a lower radiation dose than conventional CBBCT for breast imaging. • PB-CT can help clinicians diagnose patients with breast cancer.


Asunto(s)
Enfermedades de la Mama/diagnóstico , Mama/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Mamografía/métodos , Sincrotrones , Femenino , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados
6.
J Synchrotron Radiat ; 26(Pt 4): 1343-1353, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274463

RESUMEN

Breast computed tomography (BCT) is an emerging application of X-ray tomography in radiological practice. A few clinical prototypes are under evaluation in hospitals and new systems are under development aiming at improving spatial and contrast resolution and reducing delivered dose. At the same time, synchrotron-radiation phase-contrast mammography has been demonstrated to offer substantial advantages when compared with conventional mammography. At Elettra, the Italian synchrotron radiation facility, a clinical program of phase-contrast BCT based on the free-space propagation approach is under development. In this paper, full-volume breast samples imaged with a beam energy of 32 keV delivering a mean glandular dose of 5 mGy are presented. The whole acquisition setup mimics a clinical study in order to evaluate its feasibility in terms of acquisition time and image quality. Acquisitions are performed using a high-resolution CdTe photon-counting detector and the projection data are processed via a phase-retrieval algorithm. Tomographic reconstructions are compared with conventional mammographic images acquired prior to surgery and with histologic examinations. Results indicate that BCT with monochromatic beam and free-space propagation phase-contrast imaging provide relevant three-dimensional insights of breast morphology at clinically acceptable doses and scan times.


Asunto(s)
Mamografía/métodos , Microscopía de Contraste de Fase/métodos , Microtomografía por Rayos X/métodos , Compuestos de Cadmio/química , Femenino , Humanos , Sincrotrones , Telurio/química
7.
J Synchrotron Radiat ; 25(Pt 6): 1827-1832, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30407195

RESUMEN

In-line free propagation phase-contrast synchrotron tomography of the lungs has been shown to provide superior image quality compared with attenuation-based computed tomography (CT) in small-animal studies. The present study was performed to prove the applicability on a human-patient scale using a chest phantom with ventilated fresh porcine lungs. Local areas of interest were imaged with a pixel size of 100 µm, yielding a high-resolution depiction of anatomical hallmarks of healthy lungs and artificial lung nodules. Details like fine spiculations into surrounding alveolar spaces were shown on a micrometre scale. Minor differences in artificial lung nodule density were detected by phase retrieval. Since we only applied a fraction of the X-ray dose used for clinical high-resolution CT scans, it is believed that this approach may become applicable to the detailed assessment of focal lung lesions in patients in the future.


Asunto(s)
Pulmón/diagnóstico por imagen , Fantasmas de Imagen , Sincrotrones , Algoritmos , Puntos Anatómicos de Referencia , Animales , Humanos , Procesamiento de Imagen Asistido por Computador , Técnicas In Vitro , Prueba de Estudio Conceptual , Porcinos , Tomografía Computarizada por Rayos X
8.
J Synchrotron Radiat ; 21(Pt 1): 242-50, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24365943

RESUMEN

Gold nanoparticles are excellent intracellular markers in X-ray imaging. Having shown previously the suitability of gold nanoparticles to detect small groups of cells with the synchrotron-based computed tomography (CT) technique both ex vivo and in vivo, it is now demonstrated that even single-cell resolution can be obtained in the brain at least ex vivo. Working in a small animal model of malignant brain tumour, the image quality obtained with different imaging modalities was compared. To generate the brain tumour, 1 × 10(5) C6 glioma cells were loaded with gold nanoparticles and implanted in the right cerebral hemisphere of an adult rat. Raw data were acquired with absorption X-ray CT followed by a local tomography technique based on synchrotron X-ray absorption yielding single-cell resolution. The reconstructed synchrotron X-ray images were compared with images obtained by small animal magnetic resonance imaging. The presence of gold nanoparticles in the tumour tissue was verified in histological sections.


Asunto(s)
Encéfalo/citología , Oro/química , Nanopartículas del Metal , Análisis de la Célula Individual , Sincrotrones , Tomografía Computarizada por Rayos X/métodos , Animales , Neoplasias Encefálicas/patología , Glioma/patología , Imagen por Resonancia Magnética , Ratas , Ratas Wistar
9.
Nanomedicine ; 10(8): 1821-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24954384

RESUMEN

The use of alginate based microcapsules to deliver drugs and cells with a minimal host interaction is increasingly being proposed. A proficient method to track the position of the microcapsules during such therapies, particularly if they are amenable to commonly used instrumentation, would greatly help the development of such treatments. Here we propose to label the microcapsules with gold nanoparticles to provide a bright contrast on small animal x-ray micro-CT systems enabling single microcapsule detection. The microcapsules preparation is based on a simple protocol using inexpensive compounds. This, combined with the widespread availability of micro-CT apparatus, renders our method more accessible compared with other methods. Our labeled microcapsules showed good mechanical stability and low cytotoxicity in-vitro. Our post-mortem rodent model data strongly suggest that the high signal intensity generated by the labeled microcapsules permits the use of a reduced radiation dose yielding a method fully compatible with longitudinal in-vivo studies. FROM THE CLINICAL EDITOR: The authors of this study report the development of a micro-CT based tracking method of alginate-based microcapsules by incorporating gold nanoparticles in the microcapsules. They demonstrate the feasibility of this system in rodent models, where due to the high signal intensity, even reduced radiation dose is sufficient to track these particles, providing a simple and effective method to track these commonly used microcapsules and allowing longitudinal studies.


Asunto(s)
Alginatos/química , Cápsulas/química , Oro/química , Nanopartículas del Metal/química , Animales , Ácido Glucurónico/química , Ácidos Hexurónicos/química , Tomografía Computarizada por Rayos X
10.
Phys Med Biol ; 69(7)2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38471186

RESUMEN

Following the rapid, but independent, diffusion of x-ray spectral and phase-contrast systems, this work demonstrates the first combination of spectral and phase-contrast computed tomography (CT) obtained by using the edge-illumination technique and a CdTe small-pixel (62µm) spectral detector. A theoretical model is introduced, starting from a standard attenuation-based spectral decomposition and leading to spectral phase-contrast material decomposition. Each step of the model is followed by quantification of accuracy and sensitivity on experimental data of a test phantom containing different solutions with known concentrations. An example of a micro CT application (20µm voxel size) on an iodine-perfusedex vivomurine model is reported. The work demonstrates that spectral-phase contrast combines the advantages of spectral imaging, i.e. high-Zmaterial discrimination capability, and phase-contrast imaging, i.e. soft tissue sensitivity, yielding simultaneously mass density maps of water, calcium, and iodine with an accuracy of 1.1%, 3.5%, and 1.9% (root mean square errors), respectively. Results also show a 9-fold increase in the signal-to-noise ratio of the water channel when compared to standard spectral decomposition. The application to the murine model revealed the potential of the technique in the simultaneous 3D visualization of soft tissue, bone, and vasculature. While being implemented by using a broad spectrum (pink beam) at a synchrotron radiation facility (Elettra, Trieste, Italy), the proposed experimental setup can be readily translated to compact laboratory systems including conventional x-ray tubes.


Asunto(s)
Compuestos de Cadmio , Yodo , Puntos Cuánticos , Ratones , Animales , Iluminación , Fotones , Telurio , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen
11.
Sci Rep ; 14(1): 5831, 2024 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-38461221

RESUMEN

Detecting breast tissue alterations is essential for cancer diagnosis. However, inherent bidimensionality limits histological procedures' effectiveness in identifying these changes. Our study applies a 3D virtual histology method based on X-ray phase-contrast microtomography (PhC µ CT), performed at a synchrotron facility, to investigate breast tissue samples including different types of lesions, namely intraductal papilloma, micropapillary intracystic carcinoma, and invasive lobular carcinoma. One-to-one comparisons of X-ray and histological images explore the clinical potential of 3D X-ray virtual histology. Results show that PhC µ CT technique provides high spatial resolution and soft tissue sensitivity, while being non-destructive, not requiring a dedicated sample processing and being compatible with conventional histology. PhC µ CT can enhance the visualization of morphological characteristics such as stromal tissue, fibrovascular core, terminal duct lobular unit, stromal/epithelium interface, basement membrane, and adipocytes. Despite not reaching the (sub) cellular level, the three-dimensionality of PhC µ CT images allows to depict in-depth alterations of the breast tissues, potentially revealing pathologically relevant details missed by a single histological section. Compared to serial sectioning, PhC µ CT allows the virtual investigation of the sample volume along any orientation, possibly guiding the pathologist in the choice of the most suitable cutting plane. Overall, PhC µ CT virtual histology holds great promise as a tool adding to conventional histology for improving efficiency, accessibility, and diagnostic accuracy of pathological evaluation.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Rayos X , Neoplasias de la Mama/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Microscopía de Contraste de Fase/métodos , Técnicas Histológicas , Imagenología Tridimensional/métodos
12.
Opt Express ; 21(16): 19401-11, 2013 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-23938856

RESUMEN

A three-image method to extract absorption, refraction and scattering information for hard x-ray grating interferometry is presented. The method comprises a post-processing approach alternative to the conventional phase stepping procedure and is inspired by a similar three-image technique developed for analyzer-based x-ray imaging. Results obtained with this algorithm are quantitatively comparable with phase-stepping. This method can be further extended to samples with negligible scattering, where only two images are needed to separate absorption and refraction signal. Thanks to the limited number of images required, this technique is a viable route to bio-compatible imaging with x-ray grating interferometer. In addition our method elucidates and strengthens the formal and practical analogies between grating interferometry and the (non-interferometric) diffraction enhanced imaging technique.


Asunto(s)
Algoritmos , Interferometría , Fenómenos Ópticos , Absorción , Animales , Huesos/anatomía & histología , Bovinos , Rayos X
13.
Nanomedicine ; 9(2): 284-92, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22841913

RESUMEN

The ability to perform cell tracking using x-ray computed tomography combined with gold nanoparticles has been demonstrated recently on ex vivo samples using different malignant and nonmalignant cell lines. Here we proved the concept of the method for in vivo assessment in a small-animal model of malignant brain tumors. The limitations of the method due to radiation dose constraints were investigated using Monte Carlo simulations. Taking into consideration different x-ray entrance doses and the spatial resolution, the visibility of the cell clusters was evaluated. The results of the experiments conducted on mice implanted with F98 tumor cells confirmed the prediction of the Monte Carlo calculations. Small clusters of cells exogenously loaded with gold nanoparticles could be visualized using our in vivo method. FROM THE CLINICAL EDITOR: This article discusses the use of CT-based detection of gold nanoparticle loaded cells of interest in small-animal models of malignant brain tumors, where small clusters of cells loaded with gold nanoparticles could be visualized.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Oro , Nanopartículas del Metal , Tomografía Computarizada por Rayos X/métodos , Animales , Línea Celular Tumoral , Oro/análisis , Masculino , Nanopartículas del Metal/análisis , Ratones , Ratones Desnudos , Método de Montecarlo , Ratas
14.
Sci Rep ; 13(1): 4206, 2023 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-36918574

RESUMEN

This paper presents a new flexible compact multi-modal imaging setup referred to as PEPI (Photon-counting Edge-illumination Phase-contrast imaging) Lab, which is based on the edge-illumination (EI) technique and a chromatic detector. The system enables both X-ray phase-contrast (XPCI) and spectral (XSI) imaging of samples on the centimeter scale. This work conceptually follows all the stages in its realization, from the design to the first imaging results. The setup can be operated in four different modes, i.e. photon-counting/conventional, spectral, double-mask EI, and single-mask EI, whereby the switch to any modality is fast, software controlled, and does not require any hardware modification or lengthy re-alignment procedures. The system specifications, ranging from the X-ray tube features to the mask material and aspect ratio, have been quantitatively studied and optimized through a dedicated Geant4 simulation platform, guiding the choice of the instrumentation. The realization of the imaging setup, both in terms of hardware and control software, is detailed and discussed with a focus on practical/experimental aspects. Flexibility and compactness (66 cm source-to-detector distance in EI) are ensured by dedicated motion stages, whereas spectral capabilities are enabled by the Pixirad-1/Pixie-III detector in combination with a tungsten anode X-ray source operating in the range 40-100 kVp. The stability of the system, when operated in EI, has been verified, and drifts leading to mask misalignment of less than 1 [Formula: see text]m have been measured over a period of 54 h. The first imaging results, one for each modality, demonstrate that the system fulfills its design requirements. Specifically, XSI tomographic images of an iodine-based phantom demonstrate the system's quantitativeness and sensibility to concentrations in the order of a few mg/ml. Planar XPCI images of a carpenter bee specimen, both in single and double-mask modes, demonstrate that refraction sensitivity (below 0.6 [Formula: see text]rad in double-mask mode) is comparable with other XPCI systems based on microfocus sources. Phase CT capabilities have also been tested on a dedicated plastic phantom, where the phase channel yielded a 15-fold higher signal-to-noise ratio with respect to attenuation.

15.
Sci Rep ; 13(1): 4788, 2023 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-36959233

RESUMEN

Absorption-based clinical computed tomography (CT) is the current imaging method of choice in the diagnosis of lung diseases. Many pulmonary diseases are affecting microscopic structures of the lung, such as terminal bronchi, alveolar spaces, sublobular blood vessels or the pulmonary interstitial tissue. As spatial resolution in CT is limited by the clinically acceptable applied X-ray dose, a comprehensive diagnosis of conditions such as interstitial lung disease, idiopathic pulmonary fibrosis or the characterization of small pulmonary nodules is limited and may require additional validation by invasive lung biopsies. Propagation-based imaging (PBI) is a phase sensitive X-ray imaging technique capable of reaching high spatial resolutions at relatively low applied radiation dose levels. In this publication, we present technical refinements of PBI for the characterization of different artificial lung pathologies, mimicking clinically relevant patterns in ventilated fresh porcine lungs in a human-scale chest phantom. The combination of a very large propagation distance of 10.7 m and a photon counting detector with [Formula: see text] pixel size enabled high resolution PBI CT with significantly improved dose efficiency, measured by thermoluminescence detectors. Image quality was directly compared with state-of-the-art clinical CT. PBI with increased propagation distance was found to provide improved image quality at the same or even lower X-ray dose levels than clinical CT. By combining PBI with iodine k-edge subtraction imaging we further demonstrate that, the high quality of the calculated iodine concentration maps might be a potential tool for the analysis of lung perfusion in great detail. Our results indicate PBI to be of great value for accurate diagnosis of lung disease in patients as it allows to depict pathological lesions non-invasively at high resolution in 3D. This will especially benefit patients at high risk of complications from invasive lung biopsies such as in the setting of suspected idiopathic pulmonary fibrosis (IPF).


Asunto(s)
Fibrosis Pulmonar Idiopática , Enfermedades Pulmonares Intersticiales , Animales , Porcinos , Humanos , Rayos X , Pulmón/diagnóstico por imagen , Pulmón/patología , Tomografía Computarizada por Rayos X/métodos , Enfermedades Pulmonares Intersticiales/patología , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Fibrosis Pulmonar Idiopática/patología , Fantasmas de Imagen
16.
Phys Med ; 102: 88-95, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36150316

RESUMEN

PURPOSE: Clinical procedures in a Nuclear Medicine Department produce radioactive liquid and solid waste. Regarding waste release into the environment from an authorised hospital, it is mandatory to verify the compliance with European Directive 2013/59/EURATOM, adopted by the Italian Government via the Legislative Decree 101/2020. METHODS: Different activity release pathways into the environment from Trieste Nuclear Medicine Department have been analysed: liquid waste from patients' excreta discharged by sewage treatment system into the sea, and atmospheric releases following solid waste incineration. Reference models, provided by NCRP and IAEA guidelines, have been implemented to assess the impact of the discharged radioactivity for coastal waters and atmospheric transport conditions. Finally, an accidental fire event occurring in Radiopharmacy Laboratories has been simulated by HotSpot software. RESULTS: Advanced screening models give an effective dose to population of 5.3 · 10-3 µSv/y and 1.4 · 10-4 µSv/y for introduction by sewage system into coastal waters and atmospheric releases by the incinerator, respectively. Workers involved in the maintenance of the sewage treatment plant receive a total annual effective dose of 3.8 µSv/y, while for incinerator staff the total annual exposure is 5.9 · 10-8 µSv/y. For the accidental fire event the maximum total effective dose to an individual results 3.8 · 10-8 Sv with mild wind, and 4.1 · 10-7 Sv with strong wind. CONCLUSIONS: The total annual effective doses estimated to representative person, due to both Nuclear Medicine authorised clinical practices and in case of an accidental fire event, are in compliance with regulatory stipulations provided by Directives.


Asunto(s)
Medicina Nuclear , Aguas del Alcantarillado , Hospitales , Humanos , Dosis de Radiación , Residuos Sólidos
17.
Radiology ; 259(3): 684-94, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21436089

RESUMEN

PURPOSE: To prospectively evaluate the diagnostic contribution of mammography with synchrotron radiation in patients with questionable or suspicious breast abnormalities identified at combined digital mammography (DM) and ultrasonography (US). MATERIALS AND METHODS: The ethics committee approved this prospective study, and written informed consent was obtained from all patients. Mammography with synchrotron radiation was performed with a phase-detection technique at a synchrotron radiation laboratory. Forty-nine women who met at least one of the inclusion criteria (palpable mass, focal asymmetry, architectural distortion, or equivocal or suspicious mass at DM; none clarified at US) were enrolled. Forty-seven women (mean age, 57.8 years ± 8.8 [standard deviation]; age range, 43-78 years) completed the study protocol, which involved biopsy or follow-up for 1 year as the reference standard. Breast Imaging Reporting and Data System (BI-RADS) scores of 1-3 were considered to indicate a negative result, while scores 4-5 were considered to indicate a positive result. The visibility of breast abnormalities and the glandular parenchymal structure at DM and at mammography with synchrotron radiation was compared by using the Wilcoxon signed rank test. RESULTS: In 29 of the 31 patients with a final diagnosis of benign entity, mammography with synchrotron radiation yielded BI-RADS scores of 1-3. In 13 of the remaining 16 patients with a final diagnosis of malignancy, mammography with synchrotron radiation yielded BI-RADS scores of 4-5. Therefore, a sensitivity of 81% (13 of 16 patients) and a specificity of 94% (29 of 31 patients) were achieved with use of the described BI-RADS dichotomization system. CONCLUSION: These study results suggest that mammography with synchrotron radiation can be used to clarify cases of questionable or suspicious breast abnormalities identified at DM. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11100745/-/DC1.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Sincrotrones , Adulto , Anciano , Biopsia , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Sensibilidad y Especificidad , Estadísticas no Paramétricas
18.
Clin Exp Pharmacol Physiol ; 38(12): 834-45, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21957877

RESUMEN

1. Spatially resolved X-ray fluorescence (XRF) spectroscopy with synchrotron radiation is a technique that allows imaging and quantification of chemical elements in biological specimens with high sensitivity. In the present study, we applied XRF techniques at a macro and micro level to carry out drug distribution studies on ex vivo models to confirm the hepatobiliary disposition of the Gd-based magnetic resonance imaging contrast agent B22956/1. 2. Gd presence was selectively quantified allowing the determination of the time dependent disappearance of the drug from blood and its hepatic accumulation in mice after administration. Elemental mapping highlighted the drug distribution differences between healthy and diseased livers. XRF microanalyses showed that in CCl(4) -induced hepatitis, B22956/1 has greatly reduced hepatic accumulation, shown as a 20-fold reduction of Gd presence. Furthermore, a significant increase of Fe presence was found in steatotic compared with healthy livers, in line with the disease features. 3. The present results show that XRF might be useful in preclinical pharmacological studies with drugs containing exogenous elements. Furthermore, quantitative and high-sensitivity elemental mapping allows simultaneous detection of chemical variation, showing pathological conditions. This approach was useful in suggesting reduced B22956/1 accumulation in steatotic livers, thus opening possible new diagnostic perspectives for this drug.


Asunto(s)
Medios de Contraste/farmacocinética , Gadolinio/farmacocinética , Hígado/metabolismo , Imagen por Resonancia Magnética/métodos , Compuestos Organometálicos/farmacocinética , Espectrometría por Rayos X/métodos , Animales , Hígado Graso/diagnóstico , Hígado Graso/metabolismo , Femenino , Hepatitis/diagnóstico , Hepatitis/metabolismo , Hierro/análisis , Ratones , Ratones Endogámicos CBA
19.
Nanomedicine ; 7(5): 647-54, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21333753

RESUMEN

The ability to track cells in small-animal models of human disease is important because it gives the potential to improve our understanding of the processes of disease progression as well as our understanding of the therapeutic effects of interventions. In this study gold nanoparticles have been used as a permanent marker of implanted normal and malignant cell grafts in combination with a suitable x-ray apparatus. Using x-ray computed tomography the micrometric three-dimensional distribution of these marked cells could be displayed with penetration depth, high cell sensitivity and high spatial resolution in rodent models of human diseases. In principle the method allows quantification of cell numbers at any anatomical location over time in small animals.


Asunto(s)
Rastreo Celular/métodos , Oro/química , Nanopartículas del Metal/química , Coloración y Etiquetado/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Línea Celular , Línea Celular Tumoral , Movimiento Celular , Células Cultivadas , Modelos Animales de Enfermedad , Cabeza/diagnóstico por imagen , Humanos , Células Madre Mesenquimatosas/diagnóstico por imagen , Ratas , Ratas Wistar
20.
Med Phys ; 48(9): 5343-5355, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34252212

RESUMEN

PURPOSE: The SYRMA-3D collaboration is setting up a breast computed tomography (bCT) clinical program at the Elettra synchrotron radiation facility in Trieste, Italy. Unlike the few dedicated scanners available at hospitals, synchrotron radiation bCT requires the patient's rotation, which in turn implies a long scan duration (from tens of seconds to few minutes). At the same time, it allows the achievement of high spatial resolution. These features make synchrotron radiation bCT prone to motion artifacts. This article aims at assessing and compensating for motion artifacts through an optical tracking approach. METHODS: In this study, patients' movements due to breathing have been first assessed on seven volunteers and then simulated during the CT scans of a breast phantom and a surgical specimen, by adding a periodic oscillatory motion (constant speed, 1 mm amplitude, 12 cycles/minute). CT scans were carried out at 28 keV with a mean glandular dose of 5 mGy. Motion artifacts were evaluated and a correction algorithm based on the optical tracking of fiducial marks was introduced. A quantitative analysis based on the structural similarity (SSIM) index and the normalized mean square error (nMSE) was performed on the reconstructed CT images. RESULTS: CT images reconstructed through the optical tracking procedure were found to be as good as the motionless reference image. Moreover, the analysis of SSIM and nMSE demonstrated that an uncorrected motion of the order of the system's point spread function (around 0.1 mm in the present case) can be tolerated. CONCLUSIONS: Results suggest that a motion correction procedure based on an optical tracking system would be beneficial in synchrotron radiation bCT.


Asunto(s)
Artefactos , Sincrotrones , Algoritmos , Mama/diagnóstico por imagen , Mama/cirugía , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA