Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 189
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 33(5): 997-1004, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35322490

RESUMEN

INTRODUCTION: Device infections constitute a major complication of transvenous pacemakers. Mechanical heart valves (MHV) increase the risk of infective endocarditis (IE) and pacemaker infection, requiring lifelong vitamin K-antagonists (VKA), which may affect patient management. Leadless pacemakers (LP) are associated with low infection rates, posing an attractive option in MHV patients requiring permanent pacing. This study describes outcomes following LP implantation in patients with MHV. METHODS: This is a multicenter, observational, retrospective study including consecutive patients implanted with an LP at 5 centers between June 2015 and January 2020. Procedural outcomes, antithrombotic management, complications, performance during follow-up and episodes of bacteremia and IE were compared between patients with and without an MHV (MHV and non-MHV groups). RESULTS: Four hundred fifty-nine patients were included (74 in the MHV group, 16.1%, and 385 in the non-MHV group, 83.9%). Procedural outcomes and acute electrical performance were comparable between groups. Vascular complications and cardiac perforation occurred in 2.7 versus 2.3% (p = 1) and 0% versus 0.8% (p = 1) in the MHV group and non-MHV group. One case of IE occurred in the MHV group and 2 in the non-MHV group. In MHV patients, uninterrupted VKA was used in 83.8%, whereas 16.2% were heparin-bridged. Vascular complication or tamponade occurred in 1 (8.3%) MHV heparin-bridged patient versus 1 (1.6%) MHV uninterrupted VKA patient (p = .3). CONCLUSION: LP implantation outcomes in MHV patients are comparable to the general LP population. Device-related infections are rare following LP implantation, including in patients with MHV. In the MHV group, periprocedural anticoagulation management was not associated with significantly different rates of tamponade or vascular complication.


Asunto(s)
Prótesis Valvulares Cardíacas , Marcapaso Artificial , Válvulas Cardíacas , Heparina , Humanos , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 33(7): 1472-1479, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35499267

RESUMEN

INTRODUCTION: The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden. METHODS: Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h. RESULTS: Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037). CONCLUSIONS: In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/complicaciones , Humanos , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia
3.
J Cardiovasc Electrophysiol ; 31(1): 103-111, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31724763

RESUMEN

INTRODUCTION: Between 7% and 15% of patients with an indication for an implantable cardioverter-defibrillator (ICD) are not eligible for implantation of a subcutaneous implantable cardioverter-defibrillator (S-ICD) on the basis of the result of the conventional left parasternal electrocardiographic screening (LPES). Our objective was to determine the impact of systematically performing right parasternal electrocardiographic screening (RPES) in addition to conventional LPES, in terms of increasing both the total percentage of potentially eligible patients for S-ICD implantation and the number of suitable vectors per patient. METHODS AND RESULTS: Consecutive patients from the outpatient device clinic who already had an implanted ICD, and no requirement for pacing were enrolled. Conventional left parasternal electrode position and right parasternal electrode positions were used. The automatic screening tool was used to analyze the recordings. Screenings were performed in the supine and standing positions. Overall, 209 patients were included. The mean age was 63.4 ± 13 years, 59.8% had ischemic heart disease, mean QRS duration was 100 ± 31 ms, and 69.9% had a primary prevention ICD indication. Based on conventional isolated LPES, 12.9% of patients were not eligible for S-ICD compared with 11.5% based on RPES alone (P = .664). Considering LPES and RPES together, only 7.2% of patients were not eligible for S-ICD (P < .001). Moreover, the number of patients with more than one suitable vector increased from 66.5% with isolated LPES to 82.3% (23.7% absolute increase [P < .001]). CONCLUSION: Adding an automated RPES to the conventional automated LPES increased patient eligibility for the S-ICD significantly. Moreover, combined screening increased the number of suitable vectors per eligible patient.


Asunto(s)
Toma de Decisiones Clínicas , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Determinación de la Elegibilidad , Selección de Paciente , Prevención Primaria/instrumentación , Prevención Secundaria/instrumentación , Anciano , Anciano de 80 o más Años , Muerte Súbita Cardíaca/etiología , Técnicas de Apoyo para la Decisión , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas
4.
Cardiovasc Drugs Ther ; 34(1): 89-94, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32096001

RESUMEN

PURPOSE: The usefulness and mechanisms of antiarrhythmic drug (AAD) pre-treatment as a facilitator of the acute success of electrical cardioversion (ECV) in atrial fibrillation (AF) remain controversial. We sought to analyze the role of AAD treatment with this purpose, differentiating its possible utility either facilitating the restoration of sinus rhythm (SR) or reducing immediate AF recurrences (IAFR). METHODS: We analyzed 2962 consecutive patients with persistent AF undergoing ECV prospectively included in 3 national registries. The acute success of ECV was indicated by the reversion to SR without presenting an IAFR (< 2 h). RESULTS: A total of 1410 patients (48%) received AAD treatment prior to ECV (80% amiodarone, 15% class Ic AAD, 2% other AAD). The rate of restoration of SR was similar between the patients treated with amiodarone (92%), class Ic AAD (91%) and who did not receive AAD pre-treatment (91%) (p = 0.92). However, those treated with amiodarone had fewer IAFR than those in the other two groups (amiodarone 3% vs class Ic 7% vs without treatment 6%; p = 0.002), so the ECV success rate was higher in the amiodarone group than in the other groups (amiodarone 89% vs Ic 84% vs without treatment 86%; p = 0.04). After adjusting for multiple variables, amiodarone remained as an independent predictor of a lower occurrence of IAFR (OR = 0.57; p = 0.01) and of a successful ECV (OR 1.37; p = 0.01). CONCLUSIONS: For patients with persistent AF undergoing ECV, AAD has a neutral effect on the restoration of SR but amiodarone increases its effectiveness due to a lower incidence of IAFR.


Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Cardioversión Eléctrica , Frecuencia Cardíaca/efectos de los fármacos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , España , Factores de Tiempo , Resultado del Tratamiento
5.
Indian Pacing Electrophysiol J ; 20(3): 91-96, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32165268

RESUMEN

BACKGROUND: Premature ventricular contractions (PVC) are known to reduce the percentage of biventricular (BiV) pacing in patients with cardiac resynchronization (CRT), decreasing the clinical response. The aim of this study was to evaluate the prevalence of a high PVC burden, as well as therapeutic action (pharmacotherapy, catheter ablation or device programming), in a large CRT implantable-defibrillator (CRT-D) population. METHODS: Patients with a CRT-D device from the UMBRELLA multicenter prospective remote monitoring registry were included. The PVC count was collected from each remote monitoring transmission. Patients were divided into two high (≥1 transmission ≥200/≥400 PVC/h, respectively) and one low (all transmissions <200 PVC/h) PVC count groups. The PVC burden following a high PVC count transmission was calculated. RESULTS: Of 1268 patients, 135 (11%) and 43 (3.4%) presented high PVC count (≥200/≥400 PVC/h, respectively). The majority of patients in the high PVC groups were not treated (61 [79%] and 32 [74%], respectively. Considering the untreated patients in the high PVC groups, median PVC/h was 199 (interquartile range [IQR]: 196) and 271 (IQR: 330), respectively. The PVC burden (proportion of time with PVC/h ≥ 200/≥400) was 40% (IQR 70) and 29% (IQR 59), respectively. CONCLUSION: A significant proportion of CRT-D patients presented a high PVC count, however, few received treatment. In the untreated patients with a high PVC count, the PVC burden during follow-up varied substantially. Several consecutive recordings of a high PVC count should be warranted before considering therapeutic action such as catheter ablation.

7.
Pacing Clin Electrophysiol ; 42(6): 625-633, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30888071

RESUMEN

BACKGROUND: The differential diagnosis of regular wide QRS complex tachycardia (RWQRST) remains the subject of numerous publications, all of which aim at diagnosis during the acute phase. Although an accurate diagnosis is necessary to make long-term decisions, it often leads to invasive testing. METHODS: Criteria with high positive predictive values (PPVs) for diagnosis can be obtained by analyzing the electrocardiogram (ECG) data during RWQRST and comparing them with these data at baseline. By assigning points to these criteria, a scoring algorithm to accurately diagnose numerous patients can be obtained. A total of 352 consecutive patients with RWQRST were included. Two electrophysiologists blind to patient condition analyzed the 16 criteria considered as having high PPVs. RESULTS: A total of 149 (42.3%) cases were supraventricular tachycardia (SVT), and 203 (57.7%) cases were ventricular tachycardia (VT). A higher percentage of patients with VT had structural heart disease (86.7% vs 16.1%). Seven of the 16 criteria analyzed had PPVs > 95%, and each criterion was assigned a score. A final score of -1 was indicative of SVT (PPV 98%); a score of 1 was indicative of VT (PPV 98%); and a score of ≥2 was indicative of VT (PPV 100%). A score of ≠0 was obtained for 51.7% of all cases of tachycardia, making it possible to reach a highly accurate diagnosis in approximately half of all cases. No cases of VT scored -1, and no cases of SVT scored ≥2. CONCLUSIONS: The current scoring system stands out for its high PPV (98%) and specificity (98%), enabling an accurate diagnosis for more than half of the patients.


Asunto(s)
Algoritmos , Electrocardiografía , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Taquicardia Supraventricular/fisiopatología , Taquicardia Ventricular/fisiopatología
8.
Europace ; 20(7): 1161-1167, 2018 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-29036370

RESUMEN

Aims: Multipoint pacing (MPP) permits simultaneous multisite pacing of the left ventricle (LV); initial studies suggest haemodynamic and clinical benefits over conventional (single LV site) cardiac resynchronization therapy (CRT). The aim of this study was to estimate the impact of MPP activation on battery longevity in routine clinical practice. Methods and results: Patient (n = 46) and device data were collected from two centres at least 3 months after MPP-CRT device implantation. Multipoint pacing programming was based on the maximal possible anatomical LV1/LV2 separation according to three predefined LV pacing capture threshold (PCT) cut-offs (≤1.5 V; ≤4.0 V; and ≤6.5 V). Estimated battery longevity was calculated using the programmed lower rate limit, lead impedances, outputs, and pacing percentages. Relative to the longevity for conventional CRT using the lowest PCT (8.9 ± 1.2 years), MPP activation significantly shortened battery longevity for all three PCT cut-offs (≤1.5 V, -5.6%; ≤4.0 V, -16.9%; ≤6.5 V, -21.3%; P's <0.001). When compared with conventional CRT based on longest right ventricle-LV delay (8.3 ± 1.3 years), battery longevity was significantly shortened for the MPP ≤ 4.0 V and ≤6.5 V cut-offs (-10.8 and -15.7%, respectively; P's <0.001). Maximal LV1/LV2 spacing was possible in 23.9% (≤1.5 V), 56.5% (≤4.0 V), and 69.6% (≤6.5 V) of patients. Conclusion: Multipoint pacing activation significantly reduces battery longevity compared with that for conventional CRT configuration. When reasonable MPP LV vector PCTs (≤4.0 V) are achieved, the decrease in battery longevity is relatively small which may prompt the clinician to activate MPP.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Suministros de Energía Eléctrica , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Estudios Transversales , Falla de Equipo , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , España , Factores de Tiempo , Resultado del Tratamiento
9.
Europace ; 20(5): 851-858, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28387796

RESUMEN

Aims: Coronary artery spasm (CAS) is associated with ventricular arrhythmias (VA). Much controversy remains regarding the best therapeutic interventions for this specific patient subset. We aimed to evaluate the clinical outcomes of patients with a history of life-threatening VA due to CAS with various medical interventions, as well as the need for ICD placement in the setting of optimal medical therapy. Methods and results: A multicentre European retrospective survey of patients with VA in the setting of CAS was aggregated and relevant clinical and demographic data was analysed. Forty-nine appropriate patients were identified: 43 (87.8%) presented with VF and 6 (12.2%) with rapid VT. ICD implantation was performed in 44 (89.8%). During follow-up [59 (17-117) months], appropriate ICD shocks were documented in 12. In 8/12 (66.6%) no more ICD therapies were recorded after optimizing calcium channel blocker (CCB) therapy. SCD occurred in one patient without ICD. Treatment with beta-blockers was predictive of appropriate device discharge. Conversely, non-dihydropyridine CCB therapy was significantly protective against VAs. Conclusion: Patients with life-threatening VAs secondary to CAS are at particularly high-risk for recurrence, especially when insufficient medical therapy is administered. Non-dihydropyridine CCBs are capable of suppressing episodes, whereas beta-blocker treatment is predictive of VAs. Ultimately, in spite of medical intervention, some patients exhibited arrhythmogenic events in the long-term, suggesting that ICD implantation may still be indicated for all.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Bloqueadores de los Canales de Calcio/uso terapéutico , Vasoespasmo Coronario , Muerte Súbita Cardíaca , Efectos Adversos a Largo Plazo , Fibrilación Ventricular , Vasoespasmo Coronario/complicaciones , Vasoespasmo Coronario/tratamiento farmacológico , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Europa (Continente)/epidemiología , Femenino , Humanos , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/prevención & control , Masculino , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Prevención Secundaria/métodos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/terapia
10.
Pacing Clin Electrophysiol ; 41(10): 1362-1364, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30091468

RESUMEN

A 16-year-old male presented with an orthodromic atrioventricular reentrant tachycardia over a concealed parahisian accessory pathway (AP). Cryoablation of the AP resulted in transient manifestation of a fully preexcited sinus rhythm of parahisian AP morphology. Potential causes for the paradoxical preexcitation include inadvertent atrioventricular nodal block, sourse-sink mismatch, as well as the activation of a dormant AP capable of anterograde conduction.


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Fascículo Atrioventricular/cirugía , Criocirugía/métodos , Síndromes de Preexcitación/etiología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Fascículo Atrioventricular Accesorio/fisiopatología , Adolescente , Fascículo Atrioventricular/fisiopatología , Electrocardiografía , Humanos , Masculino , Síndromes de Preexcitación/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología
18.
Europace ; 18(8): 1203-10, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26566939

RESUMEN

AIMS: Currently, there continues to be a lack of evidence regarding outcomes associated with device-based therapy for ventricular arrhythmias in elderly patients, even more in primary-prevention indications. We aimed to describe the follow-up in terms of efficacy and safety of implantable cardioverter-defibrillator (ICD) therapy in a large cohort of elderly patients. METHODS AND RESULTS: Retrospective multicentre study performed in 15 Spanish hospitals. Consecutive patients referred for ICD implantation before 2011 were included. One hundred and sixty-two of 1174 patients (13.8%) ≥75 years were considered as 'elderly'. When compared with those patients <75, this subgroup presented more co-morbid conditions, including hypertension, chronic obstructive pulmonary disease , and renal failure, and more previous hospitalizations due to heart failure (HF). During a mean follow-up of 104.4 ± 3.3 months, 162 patients (14%) died, 120 in the younger age (12.4%), and 42 (24.4%) in the elderly. Kaplan-Meier analysis showed an increased probability of death with increasing age (17, 24, 28, and 69% at 12, 24, 48, and 60 months of follow-up in the elderly group). There was neither difference regarding the rate of appropriate nor inappropriate ICD intervention. CONCLUSION: In a real-world scenario, elderly patients comprise ∼15% of ICD implantations for primary prevention of sudden cardiac death (SCD). Although the rate of appropriate therapy is similar between groups, the benefit of ICD is attenuated for a major increase in mortality risk among those patients ≥75 years at the moment of device implantation.


Asunto(s)
Terapia de Resincronización Cardíaca , Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables , Hospitalización/estadística & datos numéricos , Mortalidad , Anciano , Causas de Muerte , Muerte Súbita Cardíaca/prevención & control , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Prevención Primaria , Estudios Retrospectivos , Factores de Riesgo , España , Resultado del Tratamiento
19.
Pacing Clin Electrophysiol ; 39(1): 21-7, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26173070

RESUMEN

BACKGROUND: Ventricular overdrive pacing (VOP) produces reset during the transition zone (TZ) of QRS fusion in orthodromic reentrant tachycardia (ORT) and after the TZ in atrioventricular nodal reentrant tachycardia (AVNRT), and this represents a simple diagnostic maneuver to differentiate the two tachycardia mechanisms. OBJECTIVE: The purpose of this study was to determine whether the number of beats with reset in the TZ predicts accessory pathway (AP) location in ORT. METHODS: We retrospectively reviewed 57 patients with ORT (21 left-sided AP, 20 septal AP, and 16 right-sided AP) and 20 patients with AVNRT (19 typical AVNRT and one atypical AVNRT) who underwent VOP from the right ventricular apex. We analyzed the number of beats with reset during or after the TZ, demonstrated by fixed ventricular stimulus-atrial (SA) interval during VOP. RESULTS: The overall mean tachycardia cycle length [CL] minus VOP CL was 22.6 ± 7.5 ms with no statistical difference between the groups (P = 0.480). The mean number of beats in the TZ with fixed SA interval was 2.5 ± 1.4 for the whole ORT group, 1.1 ± 0.4 for left-sided AP (range 1-2), 2.8  ±  0.9 for septal AP (range 1-5), and 4.0 ± 0.9 for right-sided AP (range 3-6) (P < 0.001). Using a cutoff >2 beats distinguished right- versus left-sided AP in all cases. CONCLUSION: Assessing the number of beats in the TZ with fixed SA interval during VOP helps to determine AP location in ORT and adds valuable information to an established simple diagnostic pacing maneuver, especially when a two-catheter simplified approach is employed.


Asunto(s)
Fascículo Atrioventricular Accesorio/diagnóstico , Fascículo Atrioventricular Accesorio/terapia , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/terapia , Adulto , Diagnóstico por Computador/métodos , Femenino , Frecuencia Cardíaca , Ventrículos Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA